West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

N-(4-Aminobutyl)-N-ethylisoluminol [Chemiluminescence Reagent]

    • Product Name N-(4-Aminobutyl)-N-ethylisoluminol [Chemiluminescence Reagent]
    • Alias ABEI
    • Einecs 629-022-0
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    527561

    Product Name N-(4-Aminobutyl)-N-ethylisoluminol
    Common Use Chemiluminescence Reagent
    Chemical Formula C13H18N4O2
    Molecular Weight 262.31 g/mol
    Appearance White to off-white powder
    Solubility Soluble in DMSO and water
    Purity Typically ≥98% (HPLC)
    Storage Temperature -20°C, protected from light
    Cas Number 83546-90-7
    Synonym ABEI
    Application Highly sensitive chemiluminescent labeling in immunoassays
    Melting Point No data available; decomposes
    Stability Stable under recommended storage conditions
    Sensitivity High sensitivity in detection assays
    Hazard Statements May cause irritation to skin, eyes, and respiratory tract

    As an accredited N-(4-Aminobutyl)-N-ethylisoluminol [Chemiluminescence Reagent] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The chemical is provided in a 100 mg amber glass vial with a screw cap, labeled with product details, barcode, and hazard information.
    Shipping N-(4-Aminobutyl)-N-ethylisoluminol [Chemiluminescence Reagent] is shipped in tightly sealed containers, protected from light, air, and moisture. It is handled as a non-hazardous chemical but may require cold pack or ambient shipping, depending on supplier conditions. Packaging complies with safety regulations for laboratory chemicals. Transport documents include material safety data.
    Storage N-(4-Aminobutyl)-N-ethylisoluminol [Chemiluminescence Reagent] should be stored in a tightly sealed container, protected from light and moisture, at 2-8°C (refrigerated). Avoid exposure to heat and incompatible substances, such as strong oxidizers. Store in a dry, well-ventilated area dedicated to chemical storage. Ensure proper labeling and access restricted to trained personnel following safety protocols.
    Free Quote

    Competitive N-(4-Aminobutyl)-N-ethylisoluminol [Chemiluminescence Reagent] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    N-(4-Aminobutyl)-N-ethylisoluminol: A Thoughtful Approach to Chemiluminescence

    Introducing Our Chemiluminescent Reagent

    Manufacturing specialty chemicals means our plant floor never gets quiet. Every batch receives our full attention, and new requests don’t get a generic answer. Among our most trusted offerings stands N-(4-Aminobutyl)-N-ethylisoluminol, a chemiluminescence reagent that draws interest from dozens of labs every quarter. Over the last decade, this compound has become a reliable part of our own work too, not just as a product but as a tested solution in our development projects.

    Many customers evaluate luminescent reagents by surface-level criteria—claims around brighter emission, easier handling, or “improved sensitivity.” As the group responsible for raw material selection, process optimization, and actual production, our team approaches these things through measured, repeatable testing. For us, it’s about real data, minimizing waste, consistent quality, and dependable performance during the reactions themselves. We know what failures look like: inconsistency in purity, unstable emission, contamination that disrupts critical results. Addressing these challenges requires hands-on experience with raw starting materials and practical observation of variables batch after batch.

    Understanding the Core Features

    N-(4-Aminobutyl)-N-ethylisoluminol, identified in literature for generating a robust chemiluminescent response, builds on the established isoluminol structure by introducing both an aminobutyl and an ethyl group. That combination delivers improved aqueous solubility and easier modification for conjugation, giving greater freedom for assay design. Our plant produces this reagent as a white to off-white crystalline powder, rigorously tested for trace metal content, water content, and organic impurities. We oversee particle size distributions to limit dust and facilitate reproducible handling.

    The reason we pay attention to details like polymorph form or residual solvent profiles comes from frequent observation of downstream effects in enzyme-linked immunosorbent assays (ELISA), Western blotting, and other analytical protocols. Even low-level contaminant profiles can introduce false positives or loss of signal stability, so we worked for years with our process engineers to tighten every quality parameter. Purity ranges consistently measure above 98%, verified through both HPLC and NMR evaluations every batch, not just on random checks.

    What Sets N-(4-Aminobutyl)-N-ethylisoluminol Apart From Other Reagents

    In our experience running side-by-side comparisons with classic luminol and other aryl-substituted analogs, this compound displays not only more intense luminescence but also extended peak emission—particularly useful for high-throughput screening platforms. It requires alkali peroxide or suitable oxidant to trigger emission, just as luminol analogs do, but users consistently find the signal holds longer above background noise.

    We take pride in producing a material that resists the sudden batch-to-batch variability seen in commodity-grade luminol derivatives. This outcome took time. Early efforts, using less rigorous purification or sourcing bulk intermediates from outside vendors, delivered unpredictable response curves and much higher variability. Our senior chemists eventually solved this by synthesizing intermediates on-site using high-purity precursors, along with non-chromatographic purification techniques, eliminating the loss of efficiency that plagued outsourced material. Direct oversight of synthesis ensures all the crucial amine protection and deprotection steps reach completion, leaving no residual byproducts that would compromise reactivity.

    Performance Advantage in Real Lab Settings

    Field tests in diagnostic kit development and food safety labs show remarkable stability under refrigerated storage (2-8°C) with negligible decline in performance across multiple months post-manufacture. Several research collaborators have also reported predictable shelf-life without the unpredictable degradation sometimes observed in more reactive luminol analogs. Our production tracks this closely with accelerated stability tests on every annual lot.

    We support partners who need reliable reagents, not a one-size-fits-all product. As a manufacturer purely focused on our own output, our relationship with N-(4-Aminobutyl)-N-ethylisoluminol is shaped by hundreds of reaction optimizations, test failures, re-engineering of batch conditions, and hands-on collaboration with technical teams who depend on precise signal detection. This level of involvement means we spot early warning signs—a faint yellowing, a musty odor, or a minuscule shift in melting point—before larger problems arise downstream.

    Common Applications And Use Cases

    The primary demand for this reagent lies in enhanced chemiluminescent immunoassays, especially those where ultra-low background and extended measurement windows are crucial. In our plant’s R&D lab, we use it to benchmark new antibody conjugation chemistries and to troubleshoot inconsistencies in prototype diagnostic kits. Our technical team regularly sets aside portions of each batch for use in standard assays designed to mimic typical customer instrumentation, verifying signal-to-noise ratios in real working conditions.

    Some partners require large-scale, multi-kilogram lots for automated clinical analyzer cartridges. Others look for small, highly pure aliquots to develop proof-of-concept detection platforms. Our experience shows that custom packaging—avoiding metal-based closures or certain lubricated septa—directly protects the sensitive amine groups and boosts usable shelf-life compared to reliance on standard packing formats.

    Dealing With Production-Scale Challenges

    The promise of a brighter emission is only meaningful if the product can be manufactured the same way every time. N-(4-Aminobutyl)-N-ethylisoluminol presents a handful of unique challenges for our production staff, including its proclivity to absorb moisture, potential for secondary amine oxidation, and occasional issues with isomeric contaminants. We noticed early batches showed inconsistencies under prolonged agitation in standard reactors, manifesting as variable rates of oxidative degradation. This led us to trial lower-exposure mixing protocols and install additional environmental controls on our crystallization lines.

    Moisture control, often overlooked, plays a critical role in maintaining the compound’s white, free-flowing appearance and chemistry. Product exposed to even minor humidity during packaging or transfer quickly picks up a yellow tinge and measurable loss of activity in high-sensitivity assays. In response, we built out a dedicated desiccant-charged packing environment and adopted single-lot labeling to track the exact exposure history of every processed kilogram.

    Safety and Handling Lessons Learned in the Field

    Production staff and lab technologists need to know how to handle material safely to avoid skin contact, eye exposure, or accidental ingestion. Based on our experience, splashes rarely occur in fully automated dispensing, but manual weighing for quality control still happens. Once, a junior operator learned the hard way about the irritant properties after brushing away a spilled trace—since then, everyone uses double-layer gloves and full eye protection, even during minor transfers.

    Over time, we have developed procedures for safe reaction quenching and waste management. The compound’s sensitivity to common oxidants and peroxides encourages constant vigilance—a stray drop of bleach or hydrogen peroxide in the wrong place can generate an unexpected flash or heat. Regular training and colorimetric monitoring for residues help prevent possible incidents. Our team continues to revise spill-cleaning procedures, particularly for larger accidental releases.

    Pursuing Improvement in QC and Instrumentation

    Maintaining instrument calibration matters for both incoming starting materials and final product batches. Our analytical chemists have expanded internal reference libraries for this compound, including MS, HPLC, and NMR spectra, allowing more accurate and quick-to-spot anomaly detection. Investigation into a handful of off-specification results led us to upgrade detector maintenance intervals and double up on internal standard checks.

    We understand the frustration from the user side when unexpected impurities or signal instability appear in finished kits or test systems. Our routine now includes monthly full-lot retesting in typical usage solutions, providing both us and our customers with more robust, up-to-date performance data. Batch certificates show these results, and we keep raw data on file for technical discussions or regulatory submissions.

    How Does It Compare?: Our Insights Beside Other Offerings

    Having produced other chemiluminescence reagents, we know N-(4-Aminobutyl)-N-ethylisoluminol stands out for its signal duration in peroxide-triggered reactions. Users who previously worked with standard isoluminol or luminol often report blunted signals or rapid fading in high-sensitivity contexts. Comparison with N-(4-Aminobutyl)isoluminol, which lacks the ethyl modification, reveals slightly lower aqueous solubility and a tendency for increased aggregation—issues we’ve tracked by direct lab measurement of dissolution times and filtering requirements.

    Some customers ask why not rely on commercial luminol. We spent time and resources on this question, running repeated comparative protocols across multiple lots, and found that side products and breakdown under storage accumulate faster in the simpler molecule. The additional ethyl group in our N-(4-Aminobutyl)-N-ethylisoluminol structure improves stability at storage conditions and offers more predictable covalent linker opportunities for bioconjugation. This translates to easier reproducibility for researchers and diagnostic kit manufacturers.

    Scaling Up: Lessons and Best Practices From Years of Production

    Chemiluminescent compounds draw the most attention during development, but challenges multiply during scale-up. Two-kilogram lots present issues that lab syntheses never reveal: localized hotspots, clumping, and environmental cross-contamination. We have learned to stagger solvent addition, slow temperature ramps, and let crystal growth proceed at its own pace under precisely controlled agitation—actions that preserve purity and reduce off-spec rework.

    Our shift supervisors train staff to record real-time observations of color shifts, viscosity, and odor, well before HPLC or NMR signals show trouble. Early detection helps avoid costly discards and ensures highest yields. Only after years of tight oversight did we reach our current state, delivering large volumes with little variation, and providing partners peace of mind around supply continuity.

    We frequently collaborate with advanced research labs pushing the limits of single-molecule detection or ultrasensitive molecular imaging. Their feedback—sometimes urgent, sometimes challenging—drives our own process tweaks, from preparative column optimization to trace metal scavenging. The cycle of feedback, production testing, and real-world assay validation is at the core of consistent, reproducible high-purity material.

    Environmental Responsibility and Waste Minimization

    Modern specialty chemical manufacture includes a strong focus on environmental impact. The synthesis of N-(4-Aminobutyl)-N-ethylisoluminol, like many aryl amine reagents, creates organic solvent waste and byproducts that require careful management. We invested in in-house solvent recovery and neutralization streams specifically to keep harmful effluents out of the waste stream. This attention contains both costs and environmental liability, and customers who scrutinize sustainability practices have audited our systems independently.

    The switch from traditional chlorinated solvents in the early years to greener alternatives took extensive process re-validation. Every time our chemists identify new routes or downstream scavenging techniques, we vet them thoroughly in pilot-scale reactors. Today, over 70% of spent solvent volume is reclaimed and recycled for on-site energy generation. Staff at every level—from engineering to routine quality control—carry responsibility for immediate spill reporting and follow-up documentation of corrective actions.

    Supporting Customers and Next-Generation Applications

    We don’t just ship boxes. Technicians working with microplate readers or Western blot imaging systems ring us for troubleshooting in the middle of their own validation work. Analytical queries come in about background noise in negative controls, best diluent choices, or impurity thresholds for their application. The technical team often spends hours troubleshooting not just our own reagent profiles but the way customers’ processes interplay with our product once it leaves our facility. Our insights, gained from daily handling and close testing, often uncover root causes beyond the chemical itself, ranging from poor instrument settings to hidden contamination from other kit components.

    We also contribute to broader scientific progress by collaborating with university labs testing the reagent’s applicability in point-of-care diagnostic prototypes or next-generation biosensing platforms. Several of the most interesting insights into assay reproducibility, reagent reactivity, and cross-reactivity risk have arisen from these partnerships. Feedback, both technical and operational, consistently drives us to invest in further R&D, pushing quality higher with each annual production campaign.

    Quality Culture Built from Experience

    After years working on the plant floor, in quality control, and in our customer’s shoes during service visits, our chemists can tell by sight, smell, or solubility curves when a batch isn’t right—even before all analysis returns. The culture on our team values these skills, encouraging mentoring among newer colleagues, sharing near-misses, celebrating production successes and process improvements. Our idea of quality goes beyond numbers on a certificate, centered in a belief that outstanding product reliability supports scientific progress in our own labs and for our customers.

    Through transparent documentation, open access to our technical expertise, and an ongoing commitment to continuous process improvement, we maintain trust in every shipment. As manufacturing veterans, we take pride in products that improve outcomes, reduce detective work for end-users, and stand up to the realities of the working lab. N-(4-Aminobutyl)-N-ethylisoluminol isn’t just another line item—it’s a finished product shaped by expertise, learning, and a passion for supporting scientific discovery at every level.