West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

IR-820

    • Product Name IR-820
    • Alias S0347
    • Einecs 942-245-6
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    170616

    Product Name IR-820
    Chemical Class Near-infrared fluorescent dye
    Molecular Formula C47H52ClN3O9S2
    Molecular Weight 902.53 g/mol
    Cas Number 144101-93-5
    Absorption Maximum 820 nm
    Emission Maximum 830 nm
    Solubility Water, DMSO
    Appearance Dark green powder
    Purity ≥95% (HPLC)
    Storage Temperature 2-8°C
    Application Fluorescence imaging

    As an accredited IR-820 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing IR-820 from Sigma Aldrich ships in a 25 mg amber glass vial with a screw cap, labeled with product and safety information.
    Shipping IR-820, shipped by suppliers like Sigma Aldrich, Merck, or TCI, is typically dispatched in tightly sealed, light-protective containers to maintain stability. It is usually shipped as a non-hazardous material at ambient temperature, following standard chemical transport regulations with proper labeling and documentation for laboratory use.
    Storage IR-820 should be stored at 2–8°C in a tightly closed container, protected from light and moisture. Ensure the storage area is well-ventilated. Avoid exposure to heat and incompatible substances. Keep the chemical in its original packaging or a suitable container clearly labeled, and adhere to the manufacturer's specific safety and handling guidelines for chemical-grade compounds.
    Free Quote

    Competitive IR-820 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    IR-820: Practical Insights From the Manufacturer’s Floor

    Learning By Doing: Why IR-820 Stands Out

    We spend much of our careers elbow-deep in colorants. IR-820 has proved itself in a class of its own among near-infrared dyes, gathering respect from those who need both reliable absorption and stability in demanding applications. The product was never just measured by a certificate; it’s how it handles batch after batch that tells the full story.

    IR-820 carries a molecular formula of C41H44N2O6S2Na2—a sodium salt, rich in its coloring performance and designed for near-infrared absorption around 820 nm. For a dye like this, the spectral properties speak loudest in research, medicine, and advanced materials. Researchers in our labs appreciate the clean profile and reliable peak, offering an absorption maximum closely centered at 820 nm. This quality opens up the technology’s full potential in areas like in vitro imaging and photothermal therapy work, where batch consistency is a non-negotiable requirement.

    Our technicians remember IR-820’s first trials in our reactors, noting its deep green appearance in powder form. Yet it is not just the shade. Switch to a diluted aqueous solution and the distinctive blue-green hue stands out right away. That immediate color change remains a quick sign of quality for chemists working at the bench and in automated processes. Through testing, technicians found that IR-820 dissolves cleanly in water with a high molar extinction coefficient, around 2.8 x 105 L·mol−1·cm−1. It helps minimize variability in work where tight dosage control matters, such as optical imaging or laser-induced therapies.

    A Practical View: Handling and Preparation

    On a busy manufacturing line, shelf life stands as a deciding factor. IR-820 gives us reliable resistance to photobleaching compared with other dyes. Under normal room lighting, it resists fading for significant periods, but storing it in amber bottles or shaded areas remains essential. The sodium salt form allows for quick rehydration and mixing. Every operator knows the headache of a dye that cakes up or clumps in storage; engineers found that IR-820’s grain remains fine and free-flowing. The powder pours evenly, with very little dust — a small detail, but crucial in large-batch setups or in cleanroom packaging.

    Our longtime blending technician recalls that, compared with other infrared dyes like IR-780 or ICG, IR-820 brings fewer solubility issues. Some dyes force us to use organic solvents just to get a workable solution; IR-820 works directly with deionized water. This reduces workplace hazards and cuts solvent waste, streamlining the workflow. Operators mixing for biomedical or analytical use appreciate the low toxicity profile. We run regular tests for trace impurities, confirming that levels of heavy metals remain well below international safety thresholds. For years, we’ve met the demands from university labs, contract research groups, and industrial partners who require rigor in every step from raw input to final batch.

    The Researcher’s Tool: Specific Applications in Imaging and Photothermal Work

    IR-820 fills a real gap for those working on optical imaging in the near-infrared window. In biomedical imaging, clear signals with minimal background interference define successful experiments, and IR-820 delivers a sharp, well-separated absorption peak. Unlike some dyes that bleed or overlap with visible wavelengths, this product keeps its profile clean and defined. Researchers running in vivo fluorescence imaging or photoacoustic studies choose IR-820 because it allows tissues to be illuminated with lower excitation energy, offering deeper tissue penetration and reduced risk of sample heating.

    Teams investigating photothermal effects, including our own, have observed how IR-820 can convert light to heat in controlled studies. The dye’s high conversion efficiency and stability under laser irradiation make it a strong option for nanoagent development and targeted ablation research. When compared to ICG (indocyanine green), one of the better-known clinical dyes, IR-820 consistently exhibits longer-lasting signals; it is less prone to rapid photodegradation under standard lab lamps or pulsed light setups.

    Practical use extends into life sciences, especially in trace detection. Our internal QC and customers have reported the dye’s ability to signal in the low nanomolar range, with minimal interference thanks to its spectral specificity. This adds a layer of reliability, lowering the detection threshold for bioanalytical tests involving proteins, nucleic acids, or small-molecule markers. In the hands of practiced operators, IR-820’s reduced background fluorescence and sharp emission profile become not just technical details, but significant time and cost savers during routine measurements.

    Comparison: IR-820 Versus Other Near-Infrared Dyes

    We’ve run side-by-side comparisons in both controlled research projects and scaled production. IR-780 and ICG remain our most common benchmarks. IR-820 outperforms IR-780 in aqueous solubility and batch-to-batch consistency. IR-780, while useful, often forces researchers to compromise on spectral purity or grapple with aggregation at higher concentrations. Our operators noticed that attempts to push IR-780 into higher concentrations for stronger signals usually cause precipitation—a headache we avoid thanks to the refined synthesis pathway we use for IR-820.

    ICG deserves mention as the clinical workhorse, especially for medical diagnostics. Yet ICG presents visible limitations in terms of chemical stability; it breaks down faster and tends to lose signal strength due to its susceptibility to oxidation. For longer research cycles, IR-820 holds signal levels over extended study periods, letting scientific teams gather more complete data from fewer runs. That means fewer repeat experiments and steadier costs, which pleases both our own R&D and those of our clients in biotech and pharma.

    During a multi-year collaboration with photonics groups, one repeated observation came out: IR-820 maintains clear signals even after several rounds of laser scanning, where ICG or IR-780 dyes had already begun to diminish by over 20%. In direct comparison, IR-820 showed far greater resistance to aggregation, supporting the researchers’ push into higher sample concentrations. The chemical backbone, designed for durability, stands up to mechanical mixing, filtration, and handling through liquid transfer pumps with little loss. Each observation reflects countless hours from our chemists questioning every step in the process, asking directly, “How does this help or hinder daily use?”

    Challenges and Responsible Manufacturing

    Manufacturing advanced dyes isn’t straightforward. A large part of our focus sits with process safety and environmental controls. For IR-820, we control temperature and humidity in all stages, preventing degradation and guaranteeing integrity. Synthesis involves a multi-step reaction with precise timing and pH control, using reagents that many other suppliers avoid due to cost or technical complexity. Commitment to in-house purification, rather than contracting out, lets us keep impurity profiles consistently low. More than once, outside labs have tried substituting our batches with generics—only to return, frustrated by inconsistent spectra and sample-to-sample variability.

    Waste streams from IR-820 production contain organic residues and sodium salts. We employ a close-loop water system to recover solvents and reprocess rinsewater, reducing landfill output and limiting worker exposure. Our long-term partners in environmental management have complimented our chemical recovery rates and our investment in exhaust-air scrubbing to keep particulate release to a minimum. Regular audits verify that each stage meets—often exceeds—regulatory and community health standards.

    Transport raises another set of practical issues. We package IR-820 under inert atmosphere, vacuum-seal heavy-gauge liners for drum-level quantities, and apply clear hazard labeling. These steps grew out of hard lessons. On one occasion, a transport delay left several competitor drums exposed to high humidity, compromising several weeks’ worth of research downstream. Our protocols prevent such losses and have protected both domestic and international shipments.

    The End User’s Experience: Customization and Feedback

    Our support teams keep close contact with researchers and production formulators. In every case, consistency takes top priority. Customers ask for specific grain sizes for different preparation equipment, so we have developed both standard and fine-milled forms. Each customization gets tested by our own R&D on high-throughput pipetting systems, ensuring that whatever batch leaves our floor performs under real-world conditions.

    Some large-scale users need IR-820 in multi-kilo quantities for diagnostic kit runs. While others, especially start-ups or university teams, want a few grams for experimental trials. The flexibility to deliver in both settings emerged from decades spent balancing the needs of bench chemists, QC departments, and regulatory reviewers. Customer feedback told us that minor differences in lot-to-lot purity could alter study results, so our analytical staff runs chromatographic and spectrometric analysis on every shipment. This gives clients reliable data to support their grant proposals, patent applications, and technical publications.

    We regularly get direct insights from users: technical supervisors in charge of photoacoustic imaging have reported reduced instrument cleaning time because IR-820 leaves fewer deposits on probes and optical components. Colorimetric assay developers mention the clean dilution curves, with less signal drift during multi-step assays. In more than one instance, diagnostics companies noted the lack of carryover between test cartridges, a result of IR-820’s minimal residual activity after washing. These insights have shaped our QA protocols and prompted investment in both staff training and new detection equipment.

    Potential Issues and Honest Solutions

    No product escapes challenges. For IR-820, the major concern comes from its sensitivity to prolonged exposure to strong acids or bases. Over the years, labs have called us to troubleshoot unexpected fading or spectral shifts—almost always tracing back to pH extremes. We respond by highlighting proper buffer usage and suggest pilot-scale tests before moving to full application. In cases where clients wanted to blend IR-820 with reactive polymers, our technical consultants worked hands-on to devise compatible mixing sequences, minimizing product loss and ensuring repeatable results.

    Another consideration is detection background. While IR-820 cleans up well in most in vitro systems, some complex biological matrices introduce interfering substances. Our experience has shown that running a few trial extractions to optimize background suppression goes a long way. We routinely support customers with sample protocols and hands-on troubleshooting, drawing on extended trials across microplate readers, flow cytometers, and imaging workstations.

    We found early on that, for bulk-scale users, proper powder handling tanks and dust collection are a must. Large-volume dispensing can create airborne particulates, no matter how skilled the technician. Over our years of improvements, we developed closed-transfer systems and offer advice on local ventilation upgrades for clients installing new systems. Combined with correct PPE, these steps support both worker health and product consistency.

    Looking Ahead: Ongoing Commitment To Quality

    Practically speaking, IR-820 owes its reliability to continuous evaluation. We don’t just set specs on a certificate; we go back to the drawing board any time a research group, regulatory body, or in-house user flags a concern. Every shift contains workers who’ve trained with us for decades, passing along practical tips on verification and storage that newer chemists often miss. Frequent review meetings include both senior scientists and junior production staff, letting us stay grounded and avoid tunnel vision.

    Change often starts at the level of raw materials. For each lot, procurement teams prioritize traceability, running supplier checks and spot-testing for extraneous ions. As regulations tighten worldwide, we stay ahead by refining washing and drying techniques, adopting cleaner reagents, and updating safety data for transport crews. Investing in both process and people, our lab staff rotates assignments so that no engineer or technician grows disconnected from the compound’s lifecycle—from procurement to blending to shipment.

    The result is a dye that continues to earn trust across fields. Fleeting trends in imaging agents come and go; IR-820 sticks around because it has consistently solved the problems that matter to chemists, clinicians, and imaging scientists. From research-grade vials to industrial-scale containers, we’ve learned that a product’s quality shows not just in the numbers, but in the hands of the people who use it daily.

    Closing Thoughts From the Manufacturer

    Every new batch of IR-820 reminds us why we take so much care at the practical level. Clean solubility, stable photophysical properties, responsible handling, and honest communication—these aren’t just checkboxes on a quality sheet, but the outcome of years spent listening to feedback, running extra tests, and investing in better equipment. At its core, manufacturing IR-820 isn’t about just providing a high-tech pigment or ticking off regulatory requirements. It’s about offering a tool that stands up to real-life scientific pressure, brings reliability to emerging fields, and earns respect in hands-on conditions.