HS Code |
931868 |
| Product Name | Heparin |
| Cas Number | 9005-49-6 |
| Molecular Weight | 15000 Da (average) |
| Chemical Formula | (C12H19NO20S3)n |
| Appearance | White to off-white powder |
| Solubility | Freely soluble in water |
| Storage Temperature | 2-8°C |
| Purity | Typically >90% |
| Source | Porcine intestinal mucosa |
| Ph 1 Solution | 5.5-7.5 |
| Application | Anticoagulant |
As an accredited Heparin factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The Heparin (Sigma-Aldrich/Merck/TCI Chemical) is supplied in a 5g amber glass vial with a secure screw cap and detailed labeling. |
| Shipping | Heparin from Sigma Aldrich, Merck, or TCI Chemical is shipped according to regulatory standards for biological reagents. Packaging ensures product integrity, often with insulation and cold packs if required. Shipping includes detailed labeling, handling instructions, and documentation for safe and compliant delivery to laboratories or medical facilities. |
| Storage | Heparin from Sigma Aldrich, Merck, or TCI Chemical should be stored at 2–8°C (refrigerated) in a tightly closed container, protected from light and moisture. Avoid freezing. Keep the container clearly labeled and away from incompatible substances. For laboratory use, store in accordance with manufacturer instructions and local regulations to maintain stability and efficacy. |
Competitive Heparin prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Heparin has a deep history in medicine as an anticoagulant, with its introduction to hospitals stretching back nearly a century. From where we stand in the plant, making heparin isn't just a process—it's a responsibility. Our teams watch every step, knowing that each batch supplies the needs of patients going through surgeries or needing regular dialysis. Years of hands-on production have shown us that meeting the expectations of clinicians demands full transparency and reliable process control, not only in the end substance but in every variable that leads up to it: starting material, careful fractionation, purification, and precise measurement.
Every year, we manufacture thousands of kilograms of pharmaceutical-grade heparin sodium, with close attention to molecular weight, potency, and clarity. A typical model in our catalog is Heparin Sodium API, refined to meet the most recent pharmacopoeia standards. It flows out of our reactors as a clear to faintly colored powder, never as a by-product or a sideline. The molecular weight average falls in the range physicians expect (between 15,000 and 18,000 Daltons), with anti-Xa and anti-IIa activities regularly validated through bioassay before anything leaves the site; these two activity points serve as benchmarks, as every clinical user wants to see the numbers line up.
Our focus never waivers from traceability. Each container connects back to its batch and, further, to raw material sources. The heparin we produce carries a unique signature dictated by our process choices: temperature control, enzyme inactivation, and repeated charcoal filtration, all of it rooted in the lessons learned over decades. Why keep talking about quality control? We’ve seen what happens if even minor steps in extraction or purification go awry. Losses don’t show up as profit margin dips—they appear as disruptions to surgeries, canceled treatments, or loss of clinical confidence.
Producing heparin demands technical insight at every stage. Our raw pig intestines arrive under constant inspection because starting out with poor material means trouble later. Raw material variability drives most of our adjustment work—texture, fat content, and mucosa thickness force us to calibrate each production cycle. Unlike downstream marketers, we absorb full responsibility from the abattoir gate through pre-purification, limiting surprises and giving us full sight on where quality hazards might start.
Extraction uses a hot water digestion system, followed by fractionation at varying pH; ionic strength has to be dialed in so contaminants drop out, leaving the glycosaminoglycan we want. Every technician knows the signals—a slight shift in color, a foam line on a tank, or sticky filtrate tells us to test and potentially re-balance the system. We never chase yield at the expense of safety. That attitude—almost a daily mantra—emerges from long learning: the people who use our product at the bedside can’t use excuses. Their questions aren’t academic, and neither are ours during each batch run.
Many in the industry think of heparin as a commodity, but for us, its batch-specific consistency has always given us an edge. The difference shows up in things like anti-Xa/anti-IIa ratios or degrees of sulfation. Whether we’re preparing bulk API or ready-to-fill sterile concentrates, we push for narrow range activity, limiting the risk of unpredictable clinical effects. Pharmacopoeial purity limits on nucleotidic fragments, dermatan sulfate, and chondroitin sulfate keep us on our toes—we use dual-stage chromatography and repeated desalting. Teams run electrophoresis and NMR (nuclear magnetic resonance) on all released lots, because hidden compositional surprises hurt trust.
Physical purity and chemical identity come together in particle size and appearance. Heparin must dissolve cleanly, colorless or barely yellow, and without residual odor. Deviation indicates incomplete purification or degradation. Endotoxin levels receive weekly review, using LAL testing—results move straight to our QMS dashboard and flagging brings everything to a halt until root causes clear. On a practical level, that means our sterile heparin can head direct to hospital pharmacies, minimizing extra handling or in-house pre-filtering at hospital sites. This lets care teams move fast, delivering to critical care or operating rooms without batch re-testing.
Most people hear “heparin” and think of post-operative thrombus control or heart-lung bypasses. From our floor, the spectrum ranges wider: low concentration syringes for catheter flushes, intermediate doses for continuous infusion in intensive care, full-dose vials for systemic anticoagulation, all the way to blood collection tube manufacturers who need surface coatings rather than bulk injectable. Each use case pushes us in different directions. The catheter flush market, for instance, wants minimal calcium binding and ultra-low protein loads—a computational headache, but one we solve through added rounds of ultrafiltration and careful ionic adjustment.
Blood contact applications always bring the greatest scrutiny, from regulators and downstream users alike. We build in extra process controls to ensure no cross-contamination occurs between heparin and other glycosaminoglycans handled in the plant. High-sensitivity endotoxin assays and rabbit pyrogen tests look for trace immunological risks. We keep a dedicated filling line isolated from broader production, with airlocks, positive pressure rooms, and validated vaporized hydrogen peroxide cycles in place. That’s the physical, on-the-ground reality of running a heparin plant in a regulatory age.
Some visitors touring our site see drums labeled for enoxaparin or dalteparin and ask about the differences to regular heparin. The division goes beyond simple molecular slicing. Unfractionated heparin, our standard product, includes a full size distribution of polysaccharide chains; these interact with clotting factors IIa and Xa, giving its broad action profile but also requiring frequent lab monitoring for dosing. Our LMWHs go through further chemical or enzymatic cleavage steps—shortening chain length, narrowing the anti-Xa to anti-IIa ratio, and reducing unpredictable binding to plasma proteins.
Health system needs drive which product type takes priority. Surgeons and acute care centers use historically full-strength heparin, seeking its reversibility with protamine and long clinical track record. Outpatient settings prefer LMWHs for subcutaneous injections and single daily dosing, cutting down on hospital time and monitoring costs. We keep separate production and validation runs for each, because their impurity profiles, activity targets, and regulatory documentation differ. Our experience confirms that no single product works for every case: full-length heparin is irreplaceable during open-heart surgery or in liver failure patients where fast reversal means everything. LMWHs, under our protocols, fit outpatient DVT prevention or oncology care, where predictable pharmacokinetics matter more.
Ask anyone in heparin manufacturing and they’ll mention the impact of global supply—pig herds, disease outbreaks, international trade policy can tighten or loosen the pipeline. Last decade, shortages hit several countries when swine fever or other disease risks wiped out raw sources. Manufacturers who rely solely on a single region or supplier risk empty shelves at critical moments. Our plant runs a diversified intake strategy, with sourced mucosa arriving from inspected facilities with both local and international traceability. Every incoming lot passes pathogen screening and antibiotic residue checks before acceptance, preventing wider contamination threats.
Scandals over adulteration remind us: trust only builds where processes open to permanent scrutiny. The 2008 chondroitin sulfate adulteration incidents traced back to loose purchasing controls. Now, we keep in-house spectrometry on every incoming and outgoing batch, blocking anything that triggers non-standard fingerprints. Investment in staff training runs year-round, giving every analyst both responsibility and formal authority to shut down questionable batches. These safeguards didn’t come from regulatory mandates—they come from lessons the industry learned the hard way, and that we’ve lived through in real time.
Heparin manufacturing never freezes in place. Pharmacopoeia revisions, new national guidelines, and growing environmental scrutiny force constant process re-design. We invest heavily in process analytics, so every alteration gets tested at pilot scale before plant-wide rollout. This includes not just classic chemical analyses, but also new tools like LC-MS (liquid chromatography-mass spectrometry) for oligosaccharide contaminants, or advanced microbiological monitoring of waste streams. Energy use, solvent recovery, and water recycling remain core priorities—the industry can’t grow if regulators or communities see unmanaged impact from factory outflows.
From personal experience, we know reactive changes cost more in downtime and lost supply than planned plant evolution. During past regulatory waves, especially after adverse events abroad, our plant teams re-documented every existing procedure, partnered with external auditors, and ran repeated “mock recalls.” This work isn’t just red tape; it means that in a true crisis, we respond with real-time batch data and full event logs, not wishful thinking or missing paper trails. Our partners—the hospital buyers, compounding pharmacies, and device partners—get proof of practice, not promises.
While standard heparin remains a backbone for surgical and acute care, we see rising demand for tailored solutions. Growing numbers of patients react poorly to animal proteins, prompting active R&D into synthetic and recombinant heparin analogues. Our in-house team works with academic groups on engineered heparinoids, but we caution users: synthetic versions, while promising, face complex path-to-market hurdles. Potency, safety, cost, and supply must all match up before any switch to non-animal sources reaches the general hospital shelf.
Our position, shaped by actual operational challenges, holds that incremental improvement—better purification, higher traceability, cleaner output—does more for safety in the short term than dramatic headline innovations. Clinicians across multiple countries reaffirm this each year: the biggest difference lies in the reliability and honesty of their partners at the point of manufacture. Our greatest pride doesn’t center on launching novel compounds; it rests on the quiet, error-free release of thousands of sterile, standardized heparin units each month.
Despite the price pressure and shifting procurement patterns, staying close to our supply and clinical partners pays off. Rapid feedback from clinical users—vascular surgeons, nephrologists, pharmacists—feeds directly into how we prioritize process improvements or product adjustments. Our teams take real questions—can we cut residual allergen loads, can we deliver more concentrated vials, can we extend shelf life—instead of chasing technical specs for specs’ sake. Regional standards, from the United States Pharmacopeia to the European Pharmacopoeia, may differ in detail but push everyone in the same direction: safer, traceable, more consistent product.
Manufacturing heparin challenges us daily, not only as a technical and regulatory exercise, but as a partnership with both patients and professionals. Each kilogram reflects choices made in the field, in the plant, and at the decision desk. Many talk about doing the right thing; we live it every day, with every batch, and every delivered vial.