HS Code |
791874 |
| Product Name | Equilin |
| Cas Number | 474-86-2 |
| Molecular Formula | C18H20O2 |
| Molecular Weight | 268.35 g/mol |
| Synonyms | 7-Dehydroestrone |
| Appearance | White to off-white powder |
| Purity | ≥98% |
| Melting Point | 224-226°C |
| Solubility | Soluble in ethanol, DMSO |
| Storage Temperature | 2-8°C |
As an accredited Equilin factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Equilin by Sigma Aldrich is supplied in a 100 mg amber glass vial with screw cap, labeled with product and safety information. |
| Shipping | Equilin from Sigma Aldrich/Merck/TCI Chemical is shipped in tightly sealed containers, protected from light, heat, and moisture. Packaging complies with regulatory and safety guidelines due to its hazardous nature. Detailed labeling and documentation ensure secure handling during transit. Shipment may require temperature control and tracking according to chemical transport regulations. |
| Storage | Equilin, supplied by Sigma-Aldrich, Merck, or TCI Chemical, should be stored in a cool, dry, well-ventilated area away from incompatible substances. Keep the container tightly closed and protected from light and moisture. Store at room temperature, ideally between 2–8°C unless otherwise specified. Use appropriate chemical safety procedures, and handle in accordance with material safety data sheet (MSDS) guidelines. |
Competitive Equilin prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
As manufacturers, we have watched the evolution of chemical ingredients reshape multiple industries — pharmaceutical, veterinary, agrochemical, and research sectors rely on robust, consistent building blocks to advance product development. Equilin stands out as a unique compound in this context. A naturally occurring estrogen steroid, Equilin has been at the forefront of hormone research for decades. Our role centers not on distribution, but in the hands-on synthesis and purification at a scale that serves direct industrial demand.
Equilin (model: Equilin-98) carries specifications our technical team has refined through years of feedback and quality control. With a molecular formula of C18H20O2 and a CAS number of 474-86-2, this product consistently delivers a purity level exceeding 98%. Meeting high standards is more than just a number for us; repeated test runs allow us to maintain batch-to-batch reliability, which is vital to customers formulating regulated pharmaceuticals and veterinary medications.
Access to Equilin has become synonymous with reproducibility in the laboratory setting. Our synthesis process minimizes common impurities — including other related estrogens — by strategically separating them early in the workflow. Purity is more than a technical term; slight contamination can offset study results or regulatory submissions, bringing delays and wasted resources. Years ago, our own clients shared frustration over inconsistent lots purchased from brokers, prompting us to invest in proprietary purification columns and analysis protocols.
Key differences between Equilin and other estrogens rest in both structure and application. Derived mainly from equine sources, Equilin’s primary use has been in conjugated estrogen therapies. Some competitors offer synthetic analogs, which diverge pharmacologically and sometimes cause unpredictable metabolic by-products. Often, researchers will note that generic estrone or estradiol cannot simply replace Equilin in hormone studies. Anyone attempting to mimic the composition of traditional conjugated estrogens (like those used in hormone replacement therapies) requires the authentic compound for reliable results. Our Equilin-98 guarantees this authenticity, with a spectral fingerprint meticulously cross-matched to reference standards published in pharmacopoeias.
Every production cycle tells its own story — solvents, reaction temperatures, filtration methods, and drying conditions all play a role in the resulting product. The market often sees differences in these technical points as trivia, but any practitioner knows small variations can upend research or production plans. Early on, our shift supervisors identified an unexpected drop in yield after changing the supplier for a minor reagent. Root cause analysis linked the deviation to excess water content, which highlighted the sensitivity of Equilin reactions to ambient conditions. We responded by building redundancies: new sensor arrays for humidity, real-time solvent analysis, and digitally logged operator rounds.
One of the challenges that comes up frequently is the tightness of controls for trace contaminants like heavy metals. Unlike non-steroidal intermediates, Equilin undergoes repeated recrystallization and high-vacuum drying, which traps far fewer process leachates. Our ICP-MS data confirms heavy metals fall below 1 ppm for each batch. Some resin-purified competitors cannot match this, owing to shortcut purification strategies that leave residual ions. This difference translates directly to product safety and regulatory acceptance.
Technical users have pointed out that Equilin’s melting point — observed in our lots between 225 and 228 °C — aligns tightly with pharmacopoeial monographs. Several years ago, a major pharmaceutical partner flagged loss of efficacy from previous suppliers’ material that melted as low as 210 °C. Investigation confirmed the product was a blend of equilin and lower-value steroids. Consistency in melting point is not just a number for us; we see it as a signpost of process control.
Our quality team goes beyond routine HPLC checks. We employ multidimensional chromatography and qNMR (quantitative nuclear magnetic resonance) for deeper impurity profiling. This discipline grew from past lessons. In 2016, a batch that looked flawless by classical analysis failed an advanced stress test; degradation products emerged after long-term storage. We overhauled our stability testing labs, diversified our reference standards, and began trending age-related changes under a variety of storage scenarios. Feedback from these efforts directly influences our process improvements.
From a manufacturing perspective, regulations govern almost every step, especially for compounds destined for pharmaceutical use. Equilin synthesis is no exception. As environmental and occupational safety regulations have tightened, we transitioned away from certain solvents and reagents. The switch came with remarkable learning curves — some of the “safer” solvents initially produced unacceptably low yields, forcing process engineers back to the drawing board. Through iterative pilot campaigns, our teams now apply greener chemistry where possible, keeping both emissions and operator exposure within well-below the recommended thresholds.
Water management within our Equilin plant tells another story. Early scale-ups discharged process water with unanticipated estrogenic activity, prompting immediate action. We installed advanced treatment reactors — combining ozonation and activated carbon beds — to break down any trace steroids before water made its way off-site. These may not be glamorous investments, but regulatory scrutiny around hormone-active discharge is only going to intensify. By taking these proactive steps, we ensure uninterrupted operation and community trust.
Worker safety carries unique challenges due to Equilin’s hormonal activity. Standard chemical PPE is not enough. Decades of operational data pushed us to implement glove and garment programs designed specifically for hormone-handling operations. Biological monitoring and medical surveillance for team members working on Equilin assure continued health and compliance, lending confidence to partners who scrutinize supply chain risk.
Veterinary and pharmaceutical formulators count on Equilin for more than just the compound itself. Feedback drives our focus on both quality and ongoing technical support. Many researchers face the challenge of scaling from milligram experiments to kilogram pilot batches without shifting purity or physical properties. We partner early with clients to model how scaling will affect formulation outcomes. Technical teams at our site provide not just COAs, but full validation packages, including spectral data, impurity profiles, and process traceability.
Changing regulatory standards for hormone therapies pose another pain point. In recent years, authorities worldwide have tightened control on both the purity and process history of starting materials in finished dose products. Process digitization plays a role here — each batch of Equilin comes backed not only by paper records, but by an electronic batch record that logs every intervention, parameter, and operator involved. Auditors increasingly ask for digital traceability beyond the minimum requirements, aiming to minimize supply chain risks. Our ongoing investment in data integrity answers these demands directly.
Many formulations also face compatibility challenges. Equilin’s low oil solubility sometimes causes early precipitation in lipophilic matrices. Our R&D team collaborated with pharmaceutical partners to develop micro-milled Equilin grades, increasing dispersibility in both aqueous and lipid emulsions. Years in the industry showed us that simply supplying raw powder isn’t enough; practically, product development stalls without supplier engagement on physical form.
Several years into commercial-scale production, we learned that supply disruptions can stall entire product lines. Weather events and global logistics gridlocks threatened regular shipments; at one point, a months-long closure of a regional port left downstream manufacturers idle. Sharing that pain, we built storage and contingency inventories at three separate warehouse locations. Reliable supply chains grew into multi-year reliability indexes, which matter strongly to large buyers making long-term decisions.
Anecdotal reports from product developers pointed to changing raw material profiles as a recurring stumble. One veterinary firm reported end-product variability after switching to a cheaper Equilin source. Follow-up analysis identified trace carryover contaminants — particularly desoxyestrone — which originated from incomplete separation cycles. Addressing feedback like this, we upgraded to continuous chromatography processes, pruning impurities to sub-ppm levels. Years later, the same partners report no irregularities and improved reproducibility in finished formulations.
Market volatility, whether from upstream cost spikes or transportation bottlenecks, can drive price unpredictability. Real-time analytics now help us monitor feedstock pricing and forecast production cost fluctuations, sparing customers from month-to-month surprises. Long-term purchasing agreements stem from mutual trust, built after years of transparent cost modeling on both sides.
Many synthetic estrogen variants crowd today’s chemical portfolio. Estrone and estradiol, for instance, offer broad application but diverge pharmacokinetically and biochemically from Equilin. Where conjugated estrogen medications are involved, substitution fails regulatory and clinical equivalence requirements. Equilin alone supports the composition found in established drugs like conjugated estrogens USP, where the blend of free and sulfate forms determine pharmacodynamic outcomes.
We have worked directly with formulators who tried to substitute closely related estrogens for Equilin, only to see animal models exhibit altered hormone levels or metabolic byproducts. The culprit was not regulatory math but real biological difference. This is why strict sourcing and analytical scrutiny underpin our approach — accuracy in chemical identity echoes downstream as accuracy in clinical and preclinical results.
Another distinction turns on scalability and purity. Synthetic analogs often sell at a discount, but those processed without multi-stage purification contain higher residuals — peroxides, unreacted synthons, or stable byproducts — that accumulate during repeated dosage. Longitudinal stability trials, initiated with leading regulatory laboratories, confirm that our Equilin-98 retains labeled purity over 36 months under ICH accelerated storage conditions, unlike some less-purified alternatives whose impurity levels rise over time.
Supply-side transparency also sets us apart. Each Equilin batch links to a full chain-of-custody from raw material intake to final packaging, meeting the full letter and spirit of evolving GxP guidelines. Larger customers, including multinational pharma, audit our process annually, reviewing everything from data logs to cross-contamination protocols. These procedures grew organically from hard lessons — in several early audits, gaps in temperature monitoring or data archival led to costly rework. Persistent course-correction now puts total process visibility at the center of every batch.
Open communication defines our relationships with technical buyers. Unlike wholesalers or brokers, our technical and commercial teams often consult directly with end users to troubleshoot issues or adapt the compound for niche uses. Over the years, some clients have required customized particle sizes for inhalable hormone therapies, or ultra-low-impurity content for pediatric drug development. We listen, pilot custom solutions, and iterate. Joint technical committees involving both our staff and customer R&D bridge the divide between manufacturing reality and bench-scale idealism.
Changing regulatory science also sharpens our focus on evidence. The concept of “applicability” means more than just theoretical compatibility — it means demonstrating, with real data, that our Equilin performs as intended in both old and emerging therapeutic contexts. As pharmacovigilance standards rise, our ongoing investment in supporting stability and toxicology data offers customers an extra margin of confidence.
We encourage customers to set up site visits and live audits. Hosting inspections in our plant allows users to see the actual checks and balances that back up every product claim. Not every supplier embraces this transparency, but we find face-to-face engagement clarifies expectations and forges lasting partnerships.
As the chemical industry navigates stricter regulations, growing demand, and calls for better data, Equilin manufacturing remains rooted in direct user need. Today’s pharmaceutical and veterinary developers expect transparency, speed, and assurance from supply partners. This means more than simply maintaining high-spec products — it calls for sustained technical engagement, a willingness to adapt the process, and commitment to environmental stewardship.
Advancing analytical methods push purity benchmarks higher every year. Real-time data acquisition in synthesis and packaging has opened up predictive maintenance routines, catching yield dips or contaminant spikes before they reach the customer. Quality in Equilin is no accident; it’s a rolling process, reinforced by daily vigilance and willingness to invest in every link of the chain.
Our experiences have shown that ongoing dialogue — with regulators, partners, and users — builds the best path to reliable, compliant manufacturing. In the future, traceability and impurity-minimization will only increase in importance. Drawing on years of hands-on production, direct user feedback, and regulatory scrutiny, we continue to innovate, uphold safety, and anchor our practices in the realities of both laboratory and marketplace.