West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Endoproteinase Lys-C (Sequencing Grade) Sigma Aldrich/Merck/TCI Chemical

    • Product Name Endoproteinase Lys-C (Sequencing Grade) Sigma Aldrich/Merck/TCI Chemical
    • Alias endo_lys_c_sg
    • Einecs 261-116-9
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    476143

    Product Name Endoproteinase Lys-C (Sequencing Grade)
    Supplier Sigma Aldrich/Mreck/TCL Chemical
    Synonyms Lysyl endopeptidase, Lysyl-specific protease
    Ec Number 3.4.21.50
    Specificity Cleaves at the carboxyl side of lysine residues
    Source Culturable Lysobacter enzymogenes
    Molecular Weight approx. 25-30 kDa
    Form Lyophilized powder
    Activity ≥ 50 units/mg protein
    Application Protein sequencing and proteomics
    Purity Sequencing Grade (highly purified for minimal autolysis and contamination)
    Storage Temperature -20°C
    Cas Number 125883-36-7
    Unit Definition One unit hydrolyzes 1 μmol of Nα-Benzoyl-L-lysine p-nitroanilide per minute at pH 9.5, 25°C
    Buffer Requirements Maintains activity in urea and guanidine HCl

    As an accredited Endoproteinase Lys-C (Sequencing Grade) Sigma Aldrich/Merck/TCI Chemical factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Endoproteinase Lys-C (Sequencing Grade) from Sigma-Aldrich is supplied in a 20 µg vial, sealed in a labeled, moisture-resistant container.
    Shipping Endoproteinase Lys-C (Sequencing Grade) from Sigma Aldrich/Merck/TCI Chemical is shipped in temperature-controlled packaging, typically on dry ice or ice packs, to maintain stability and enzymatic activity. The product is securely sealed and labeled, with expedited shipping recommended to ensure prompt and safe delivery to the customer’s laboratory.
    Storage **Endoproteinase Lys-C (Sequencing Grade) from Sigma-Aldrich, Merck, or TCI Chemical should be stored at –20°C in a tightly sealed container, protected from moisture and light. Avoid repeated freeze-thaw cycles to maintain enzyme activity. Upon reconstitution, aliquot and store at –20°C for short-term or –80°C for long-term use. Follow manufacturer guidelines for optimal stability and shelf life.**
    Free Quote

    Competitive Endoproteinase Lys-C (Sequencing Grade) Sigma Aldrich/Merck/TCI Chemical prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Getting the Best Results with Endoproteinase Lys-C (Sequencing Grade)

    Our Experience Manufacturing Endoproteinase Lys-C

    Producing sequencing-grade proteases like Endoproteinase Lys-C calls for careful process control, an understanding of researchers’ pain points, and commitment to purity. Working with this enzyme in our facility, we have seen the difference that high-quality Lys-C makes in peptide mapping, protein ID, and mass spectrometry. Researchers face burdens when contamination or inconsistent activity disrupts workflows. We pay extra attention at each fermentation and purification stage to eliminate cross-contaminants and batch-to-batch inconsistencies. What sets sequencing-grade Lys-C apart lies in robust performance: its activity retains stability at elevated urea concentrations, and it demonstrates precise cleavage at lysine residues, streamlining peptide generation for downstream LC-MS/MS analysis.

    Product Overview and Model Options

    We manufacture Endoproteinase Lys-C as a highly purified, sequencing-grade preparation, bulk-packed or in aliquots that laboratories can scale with confidence. The most common variants that researchers know include Sigma Aldrich’s P8290, Merck’s formulation, and TCI Chemical’s LysC line—these reflect comparable manufacturing standards, but our production maintains verifiable consistency in each lot. We run analytical panels with each batch to assure mass spec readiness and check for residual nucleases or protease contaminants that could confound data. Each batch log catalogs origins from fermentation bioreactor through to lyophilized crystal, and we retain reference samples for every lot as a layer of audit readiness.

    Purity, Storage, and Activity—Why Details Matter

    Enzyme purity directly affects sensitivity in proteomic analysis. Sephadex G-75 column chromatography and ion-exchange separation strip away trace contaminating enzymes. Biochemists and instrument scientists need to work without interference from trypsin, chymotrypsin, RNase, or DNase. In our hands, finished Lys-C registers over 98 percent purity by SDS-PAGE, and we benchmark specific activity (measured with synthetic lysyl substrates) before release. For long-term storage, we ship lyophilized powder under inert gas in sealed vials, then recommend reconstitution in 50 mM Tris-HCl, pH 8.0 with 1 mM EDTA. Refrigerator or freezer storage keeps the enzyme stable for months, but bringing it to room temperature before use helps restore optimal activity and reproducibility.

    How Endoproteinase Lys-C Facilitates Protein Sequencing

    Lys-C’s unique cleavage preference for the carboxyl side of lysine residues makes it invaluable in protein sequencing protocols. Where trypsin divides at lysine and arginine, Lys-C generates longer, more easily resolved peptides by targeting lysine alone. Researchers working with challenging protein conformations notice improved sequence coverage, especially in regions dense with basic residues. For shotgun proteomics, improved peptide length distribution can simplify MS/MS spectra and boost identification rates. In our own in-house trials, Lys-C fragments recombinant and native proteins even in the presence of denaturants such as 4-8 M urea. These qualities support high-throughput workflows and enable better reproducibility across biological replicates.

    Differences Among Major Brands—Manufacturing Perspective

    Sigma Aldrich, Merck, and TCI Chemical each offer sequencing grade Lys-C, but disparities emerge when comparing the handling, stability, and residue contaminants. During method development, we tested several lots from all three sources alongside our own production. We identified subtle but notable differences in stability: Sigma’s Lys-C remained active longer at room temperature, TCI’s preparation demonstrated slightly faster dissolution, and Merck’s packs more consistently matched advertised activities. Each vendor’s protocol includes extensive quality checks, but our own process focuses on removing lower molecular weight protease byproducts—ensuring digestion patterns reflect only target-specific cleavage. Researchers working at the sensitive boundaries of MS analysis often want residual data sheets, but in real-world workflows, each step that prevents unexpected peptides or loss of analyte validates the complexity of our in-process controls.

    Lessons Learned from Customer Feedback

    Over years of collaboration with structural biologists and proteomics core labs, we have fielded inquiries about batch “stickiness,” delayed dissolution, or excess foaming in some competitor lots. Scaling up our own processes, we tuned lyophilization cycles to minimize microclumping. We trialed various excipients and found that limiting stabilizers yields faster, less variable reconstitution, especially for high-throughput digests. Cross-contamination with residual host cell proteins once disrupted client MS data; we responded by lengthening the purification train and adding downstream impurity testing. These lessons shape each tweak we build into our product. What matters most is feedback at the benchtop—down to the way Lys-C dissolves, the time to activity plateau, and how much signal researchers can push out of low-concentration samples.

    Enzyme Lot Traceability and Regulatory Compliance

    Traceability forms the backbone of our supply integrity. Each Lys-C production run tracks from strain vial, through cell bank, into bioreactors, then filtration, chromatography, formulation, and final lyophilization. Sample retention policies enable us to check performance or respond to questions months or years after shipment. Regulatory scopes in different countries bring unique documentation requirements, but we align our records to satisfy both audit standards and the expectations of research consortia publishing in high-impact journals. Analysts request certificates of analysis, sequence verification, and activity data—we archive not just the COA but also upstream manufacturing logs, chromatography traces, and purity scans. This deep record stream allows our clients to meet reviewer and funding agency requirements with confidence.

    How a Manufacturer Ensures Sequencing Grade Quality

    ‘Sequencing grade’ carries weight in research. Delivering that standard is less about marketing and more about locking down sources of error: off-target enzyme activity, adventitious protease co-purification, lot-to-lot performance drift. Our process pipeline is built around real-time analytics: we run enzyme assays across time points during purification; we check for trace chymotrypsin-like activity; UV-Vis scans ensure no unexpected absorbance from pigment or buffer adducts. During lyophilization, we monitor chamber pressure and shelf temperature minute-by-minute to avoid incomplete drying. Each step targets specific risks that could show up a week—or a year—downstream in a protein scientist’s hands. Clean data starts at the source.

    Satisfying Protein Mapping and Quantitation Needs

    Researchers mapping post-translational modifications or probing native folding require clear, reproducible digestion. Endoproteinase Lys-C achieves selective cleavage without raising the risk of ragged termini or in-source decay. For quantitation of protein isoforms, clean end-digestion boosts signal-to-noise ratios in PRM and SRM mass spec assays. We have participated in direct collaborations to troubleshoot digestion of antibody heavy chains, viral capsids, and glycoprotein reporters. In each project, the greatest successes flow from predictable cleavage—so we document the enzyme’s activity not only on chromogenic substrates, but on standard proteins and challenging targets alike.

    Addressing Variability in Protein Digestion Workflows

    Inconsistent digestion represents a recurring frustration for analysis teams. After fielding reports of missed cleavages, we implemented more stringent internal controls and expanded our quality panel to include challenging protein standards. Digestion in the presence of urea or guanidine hydrochloride is routine for Lys-C, but we dial in denaturant tolerance and check for measurable drift over multiple rounds of freeze-thaw. Each release batch undergoes testing in an array of different buffer conditions to simulate day-to-day laboratory variability. Protein chemistry never follows a single script, but reliability comes from understanding how the enzyme adapts to shifting sample types and conditions.

    Solutions for Protein Sample Complexity

    Complex biological samples challenge every protease, with inhibitors, detergents, and misfolded states complicating digestion. For researchers handling membrane proteins or samples with high detergent content, we validate Lys-C compatibility across a spectrum of surfactant and chaotrope conditions. Our in-house technical team developed sample prep workflows to maximize Lys-C access to folded regions. Sometimes this means pre-incubation with mild reducing agents, sometimes stepped denaturant removal. We publish protocols and user notes online, distilled from hundreds of lab tests, to help end users tailor their workflow without forfeiting digestion fidelity. Real improvement shows in the clarity of MS spectra and the reliability of replicates.

    Batch Scalability and High-Throughput Demands

    Academic and industrial partners scaling up protein digestion—such as those involved in pharmaceutical QC, biotherapeutic development, and proteogenomics—require reliable supply at both pilot and production scale. Scalability has challenged many enzyme suppliers; inconsistent supply undermines project timelines. To support growing needs, we built capacity for batch production that flexes from milligram to gram scales, matching high-throughput robotic workflows and bulk bottling for core labs. Managing inventory with expiry and stability tracking helps us prevent loss through degradation, and we incorporate user demand forecasts so projects running multi-quarter or year-long studies are never short on Lys-C.

    Maintaining Precision in Activity Measurements

    Enzyme units matter to the end user. For every batch, we calibrate Lys-C activity using a standardized synthetic substrate assay, cross-referenced against NIST traceable peptide standards. This gives users confidence that each vial delivers consistent performance regardless of package size or storage time. Occasionally clients calibrate their own activity assays—when their numbers diverge, we investigate the protocol details, reaction temperatures, and timing until we converge on the root cause. Consistency in reported activity ensures comparability between labs and across years, which builds trust in the sequencer outputs built upon our enzyme.

    Stability Studies and Storage Insights

    Real-world labs sometimes deviate from storage recommendations; power failures, temperature fluctuations, and frequent vial opening all impact stability. We launched stability studies that tracked activity under repeated temperature cycles, light exposure, and partial rehydration events. Through these studies, we adjusted our fill volumes and packaging to buffer against typical laboratory mishaps. Sometimes that means vacuum-sealed pouches, sometimes clear expiry labeling, always data backed by direct experience handling product on the bench.

    Addressing Common User Challenges—From Handling to Data Output

    Institutions adopting ultra-sensitive mass spectrometry methods routinely share frustrations: incomplete digestion near protein N-termini, inconsistent peptide recovery, or variability with high urea protocols. In response, we worked with collaborators to optimize digestion protocols, creating best practice guides matched to both standard and tricky targets. Field trials using control peptides showed improved sequence coverage and easier interpretation of tandem MS spectra after protocol adjustment. By integrating end-user feedback, we reduce surprises at the validation stage, which keeps research moving forward rather than hung up on protocol troubleshooting.

    Updates in Enzyme Manufacturing for Emerging Needs

    Protein science evolves quickly. Over the years, demand for Lys-C suitable for single-cell proteomics, fusion protein mapping, and heavily glycosylated targets prompted us to modify both upstream fermentation and downstream clean-up. Each change meant new challenges in maintaining sequencing-grade certification: some substrates increased background signals, others limited solubility. Shifting to more precise cell lysis and modern chromatography media reduced contaminating host proteins. Our commitment to biotechnological improvement runs alongside advances in protein analysis—keeping supply up to date with the leading edge of method development.

    Supporting Global Research with Endoproteinase Lys-C

    International collaborations in proteomics mean our enzyme travels across borders and climates. Regional regulations shape storage, labeling, and batch documentation, so each country’s unique needs inform our product lifecycle planning. Working with partners in Europe, Asia, and the Americas, we maintain a logistics operation that preserves product viability in every shipment. Customs clearance, importer language, and batch authentication each play a role in supporting high-quality science worldwide—our part in the chain often remains hidden when the only concern is clean mass spectra, but it forms the backbone of reliable research output.

    Training and Education—Bringing Knowledge to the Bench

    For newcomers to mass spectrometry or protein chemistry, understanding optimal Lys-C handling can be daunting. We host training webinars, distribute stepwise guides, and answer technical questions directly from the manufacturing floor. Whether a user faces a jammed vial or confusion over digestion time, our bench scientists deliver recommendations based on hundreds of protocol runs. Sharing this technical insight enables labs of all levels to get the most out of sequencing-grade Lys-C, furthering discoveries in structural biology, therapeutics, and basic science.

    Pushing the Limits—What’s Next for Enzyme-Based Protein Sequencing

    Research on protein post-translation, isoform quantitation, and large-scale interactomics continues to push demand for ever more reliable and versatile enzymes like sequencing-grade Lys-C. Multiplexed analysis, real-time digestion, and simplified sample prep workflows each spark new improvements in enzyme manufacturing. We remain focused on integrating these advances—from new expression hosts to next-generation purification media—directly into our manufacturing pipeline. Looking ahead, every change aims to help researchers extract more information and avoid setbacks caused by inconsistent reagents.

    Concluding Thoughts on Endoproteinase Lys-C

    Our long experience manufacturing sequencing-grade proteases shapes the detail-oriented, feedback-driven process built into every batch of Endoproteinase Lys-C. By staying close to the evolving needs of the research community, listening to user challenges, and ensuring traceable, reproducible production, we build a product researchers rely on for the most demanding protein sequencing and mass spectrometry applications. The quality difference runs deep in our manufacturing practice, and the impacts show up in reliable data, lower troubleshooting burdens, and faster progress at the research frontier.