West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Dihydrorhodamine 123

    • Product Name Dihydrorhodamine 123
    • Alias DHR 123
    • Einecs 602-705-4
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    362186

    Product Name Dihydrorhodamine 123
    Cas Number 109244-58-8
    Molecular Formula C21H17N3O3
    Molecular Weight 359.38 g/mol
    Appearance Off-white to pale yellow solid
    Solubility Soluble in DMSO, ethanol
    Purity Typically ≥98% (HPLC)
    Storage Temperature -20°C, protected from light
    Fluorescence Ex Em Ex: ~500 nm, Em: ~536 nm (upon oxidation to rhodamine 123)
    Application Reactive oxygen species (ROS) detection
    Synonyms DHR 123, Dihydrorhodamine-123

    As an accredited Dihydrorhodamine 123 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Dihydrorhodamine 123 (Sigma-Aldrich/Merck/TCI Chemical) is supplied in an amber glass vial, 5 mg, with tamper-evident seal.
    Shipping Dihydrorhodamine 123 is shipped by Sigma Aldrich, Merck, or TCI Chemical in specialized, light-protective packaging to prevent degradation. The product is often sent at ambient temperature, but shipping conditions may vary depending on regulatory requirements. Documentation and safety data sheets are included to ensure compliance with chemical transport regulations.
    Storage Dihydrorhodamine 123 should be stored protected from light at −20°C in a tightly sealed container. Exposure to light, air, or moisture may degrade the compound. Avoid repeated freeze-thaw cycles. Store in a dry, cool environment, away from incompatible substances and sources of ignition. Follow Sigma-Aldrich, Merck, or TCI Chemical’s specific guidelines for maximum stability and safety.
    Free Quote

    Competitive Dihydrorhodamine 123 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Dihydrorhodamine 123: Our Experience Creating a Reliable Fluorescent Probe

    Introduction

    Every year, researchers in cell biology and biochemistry demand more precision. Their live cell imaging and flow cytometry experiments depend on robust, sensitive detection tools. We understand where these requirements come from—you cannot run a reliable assay without proven performance from your chemical reagents. Over years of producing high-purity fluorescent probes, we settled on a simple way to meet these expectations: control every step of the manufacturing process, know the science behind our materials, and track the results in real-world labs. Dihydrorhodamine 123 stands out in this context. It is much more than a stock-line item; it is a specialty compound that results from a deliberate approach to both chemistry and practical need.

    What Makes Dihydrorhodamine 123 Unique

    Our team synthesizes Dihydrorhodamine 123 to meet the high standards set by analytical, clinical, and research labs worldwide. Chemically, it is a reduced, nonfluorescent derivative of rhodamine 123. Exposure to reactive oxygen species (ROS) transforms it into brightly fluorescent rhodamine 123—a property that makes it valuable for detecting oxidative bursts and free radical production within live cells. Many labs deploy Dihydrorhodamine 123 in flow cytometry, microscopy, or high-throughput screening campaigns because its signal-on transformation means background interference remains minimal.

    Compounds like this do not simply tumble off a production line. We have spent years refining the means to deliver Dihydrorhodamine 123 with consistent purity, stability, and responsiveness. Even minor contaminants or improper storage can translate to unreliable signals. Feedback from customer labs—sometimes a frustrated call, sometimes a collaborative troubleshooting session—drives our commitment to extremely low impurity levels and diligent packaging practices. Before leaving our site, every lot passes a combination of spectroscopic verification and functional assays that verify the liberation of the rhodamine structure only through oxidation, not light or common solvents.

    Specifications and Manufacturing Considerations

    Dihydrorhodamine 123’s molecular form—C21H19N3O2—is sensitive to both light and oxidation. Few compounds demonstrate such a precise transformation under ROS stress, and that sharp switch is what scientific customers require. We package the material under inert gas, in light-blocking vials, and ship every batch with exact documentation of assay verification and lot-specific mass spectrometry data. These details may sound technical, but they trace directly to reliability at the bench: if a reagent claims to show ROS, it must stay inert until the precise moment of assay activation.

    Some producers bulk-manufacture fluorescent dyes with a focus on fragmentation across product lines. We focus on core chemistry and process discipline. Our Dihydrorhodamine 123 typically ships as a crystalline powder, though we also provide custom solution packaging for volume users who require consistency on automated platforms. Lab customers using single-cell sequencing tools or multi-well readers often request those pre-dissolved formats to avoid human error and save time during sample prep.

    To avoid compromised signal, we monitor every material input. We train staff on the delicate aspects of synthesis—handle the sodium borohydride precisely, never allow trace water into certain steps, watch both temperature and pH very closely. As a producer, the difference between a crisp, bright transformation and one riddled with background largely depends on process discipline and raw material purity. We keep batch records with quantified impurity levels, and over time we have tightened these controls after seeing too many off-the-shelf “bargain” suppliers fail under the scrutiny of advanced flow cytometry.

    Applications and Real-World Utility

    Most scientists who request Dihydrorhodamine 123 use it as a probe for oxidative activity within living cells. Reactive oxygen species (ROS) detection is the headline benefit, but the underlying advantage comes from low cytotoxicity and a near-absence of autofluorescence before activation. In our experience, this compound significantly outperforms generic rhodamine derivatives or broad-spectrum peroxide sensors in sensitivity to physiological oxidative bursts. We hear from cell biologists studying immune activation, cancer signaling, or mitochondrial stress pathways that other dyes either introduce artifacts or lose specificity outside ideal lab conditions. Dihydrorhodamine 123’s unique activation mechanism sets it apart in these critical experiments.

    For flow cytometry, the dye loads easily into most cell types, and we optimize particle size to maximize cell permeability while minimizing aggregation. A recurring problem with less-refined dyes involves non-specific binding or precipitation, which destroys single-cell data resolution. Replicating a customer’s data from a high-throughput cytometer, we watched how small improvements to our crystallization step cut down background events by over 30%. That led to wider adoption among core facilities and high-end academic labs, many of whom had grown skeptical of dyes from vendors with no real manufacturing oversight.

    Beyond single-cell work, many clinical diagnostic labs use Dihydrorhodamine 123 to assess neutrophil function or define oxidative burst capacity in blood samples from immunocompromised patients. Here, reproducibility forms the backbone of trust: one compromised measurement could mean the wrong diagnostic decision. We do not take that risk lightly, so every unit we send out is annotated with full batch history and traceable to each reagent lot used during synthesis. Over years of feedback, we know that our efforts translate to fewer failed runs and more reliable decision points for end users.

    Comparison With Other Fluorescent Dyes

    The world of fluorescent probes is crowded with alternatives—classic rhodamine 123, dichlorodihydrofluorescein diacetate (DCFH-DA), dihydroethidium, and many others. Some offer higher maximum quantum yields, some deliver broader emission profiles, and some claim faster response kinetics. Still, users face trade-offs. Rhodamine 123 itself fluoresces without prior oxidation and cannot distinguish between non-specific uptake or oxidative activation. DCFH-DA sometimes over-reports ROS in the presence of other reducing or oxidizing agents, muddying the results.

    Dihydrorhodamine 123 offers practical selectivity by remaining nonfluorescent until oxidation happens inside the cell. This means users can wash cells and minimize background in multi-step protocols. Users running multi-color panels have told us how non-overlapping excitation/emission settings allow easy integration into complex cytometry panels. This property alone wins converts from labs frustrated with “leaky” dyes or those forced to redo experiments due to spectral overlap.

    Some specialty fluorescent probes chase extreme sensitivity but sacrifice shelf life or introduce toxicity to living cells. We resisted that trade-off. Instead, we balanced stability (shelf life stretches far past a year under recommended storage), low cell toxicity (as proven again and again by users reporting high cell viability), and consistently bright signal after ROS activation. The trick lies in nailing the synthetic route and handling logistics correctly, not relying on labelling tricks or overengineered packaging. Even after tens of thousands of vials, that equation has not changed for us: keep the chemistry clean, the documentation thorough, and the end-user’s priorities in mind.

    Challenges and Solutions in Manufacturing

    Chemical manufacturing rarely plays out as a straight line. Producing Dihydrorhodamine 123 has taught us the value of quality assurance and iterative process review. Early attempts at scale-up revealed how overly rapid cooling and poor mixing create batch inconsistencies. The feedback loop from research users catches every miss: batch-to-batch variability carries real consequences in both discovery science and clinical measurement.

    Meeting these challenges demanded a tighter approach to raw material testing and sharper in-process controls—at every stage, from first reduction through the final chromatographic polish. Solvent purity checks, measurement of trace metals, and control of environmental exposure all contribute to a final product that users can trust. We talk with scientists about their most finicky assays because their feedback reveals shifts in product quality before pure analytical data catches the drift.

    Handling and shipping fluorescent dyes for global customers requires more than a cold room. Our approach begins with custom packaging designed to block light and moisture. During summer heat waves, we learned to use thermal tracking and real-time carrier logs to adjust packaging and delivery methods, so research teams in humid climates or tropical regions receive uncompromised material. These are small steps, but they make the difference between a reliable, ready-to-use probe and an unusable batch lost to ambient conditions in transit.

    User Feedback and Process Evolution

    We do not rely solely on internal QC or analytical method validation. The best insights come from hands-on scientists using Dihydrorhodamine 123 in large-scale screens, diagnostic pipelines, or pilot studies. When a team flags unexpected results, we track the material back through each process step and lot. Labs running high-throughput research in immunology and oxidative stress now provide real-world test conditions unavailable inside most manufacturing facilities. Their concerns and results guide our iterative improvements, from tightening solvent controls to refining the final lyophilization and powder-handling protocols.

    One recurring theme: experienced users want both transparency and predictability. They want to know exactly how each batch performs, how much variance to expect, and where the raw materials originated. That transparency strengthens trust; we respond with direct conversations and open documentation, giving users one less variable to chase when troubleshooting complex biological assays.

    As more institutions move toward automated and high-content screening methods, we have adapted packaging and documentation formats. Each new workflow presents another stress-test, and each one pushes our process improvements in directions not obvious from the outside. For example, when several drug discovery projects started using Dihydrorhodamine 123 in multiplexed, multi-day screens, we adjusted the crystal size distribution to reduce clumping in liquid handling robots. Some changes originate in the lab, others from logistics specialists—real product development always flows both ways.

    Staying Ahead in a Rapidly Evolving Field

    Over decades, the landscape of cell imaging has changed. Assay complexity grows, detection platforms become more sophisticated, and user expectations stretch further. Dihydrorhodamine 123 remains a mainstay for ROS detection because it survives the scrutiny of evolving techniques. Each time a lab integrates our compound into a new format—whether single-molecule detection, miniaturized organoid assays, or companion in vivo imaging—they report similar needs: signal reliability, minimal background, straightforward sample prep, and honest, prompt support when questions arise.

    Competition continues to ramp up, as new probes hit the market and technology platforms blend fluorescent dyes with digital, AI-driven workflows. We keep pace by refining internal analytical standards, sharing results with our research partners, and consistently updating storage and transport practices according to global conditions. No static formula or product sheet substitutes for hands-on engagement and learning from users. We invest heavily in analytical assets, but just as much in the human conversations that reveal emerging research needs.

    Environmental and Regulatory Considerations

    Responsible chemical manufacturing does not exist in a vacuum. Producing Dihydrorhodamine 123 involves handling solvents and intermediates that require both skillful containment and disciplined waste stream management. We design our process to limit waste, recycle solvents wherever possible, and document EPA and regional compliance for every release batch. Any deviation or spill prompts a root cause review, and we never shortcut the safety and sustainability procedures verified by years of environmental monitoring.

    Many labs now look beyond performance and price, demanding assurance that the products they use align with institutional sustainability goals. As a manufacturer, we continuously weigh raw material sourcing and energy use against product yield and purity metrics. Every new regulatory guideline—from transport to packaging to ingredient traceability—requires investment of time and resources. Still, these efforts create benefits up and down the supply chain: less waste, safer labs, and products that meet local and global standards without a drop in quality.

    The Future of Dihydrorhodamine 123 as a Research Tool

    For us, Dihydrorhodamine 123 is not a relic of the past or just another product number. It is a tool that helps labs push the frontiers of oxidative signaling research and reliable diagnostics. We see new requests for tailored variants—altered solubility profiles, custom fluorophore conjugates, and specialized vials for field kits. These arise from evolving research needs, and addressing them brings us deeper into the practical side of science innovation.

    The growing use of automated cell analysis platforms, organ-on-chip models, and live-tissue imaging all point toward higher bar for every ingredient in the workflow. Meeting those standards requires close collaboration across the chemical manufacturing process, supply chain oversight, analytical testing, and hands-on support to users. Seeing our Dihydrorhodamine 123 catalyze new discoveries—and help deliver better patient outcomes in clinical labs—provides a real reason to keep refining both product and process, every year.

    Conclusion

    Our experience with Dihydrorhodamine 123 encapsulates the real-world demands of modern chemical manufacturing. It is not just about scaling chemical reactions or shipping more units. Every small decision, from raw material testing to batch QC to packaging, shapes how this compound performs in university labs, hospital diagnostics, and pharma discovery pipelines. Staying accountable to those who use our dye—whether running a routine blood test or mapping ROS signaling in a new disease model—remains our guiding principle. Through focus, feedback, and a respect for the rigorous realities of scientific work, we keep delivering a fluorescent probe that actually does what today’s scientists need, with each lot as reliable as the last.