HS Code |
971653 |
| Product Name | Diclofenac Related Compound A |
| Synonyms | 2-Anilinophenylacetic acid |
| Cas Number | 2217-94-1 |
| Molecular Formula | C14H13NO2 |
| Molecular Weight | 227.26 g/mol |
| Appearance | White to off-white powder |
| Purity | Typically ≥98% |
| Solubility | Soluble in DMSO, methanol |
| Storage Temperature | 2-8°C (refrigerated) |
| Catalog Numbers | Sigma Aldrich D7217, Merck 2217-94-1, TCL Chemical 2217-94-1 |
| Inchi Key | QIQARGGCWXNQLT-UHFFFAOYSA-N |
As an accredited Diclofenac Related Compound A factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging for Diclofenac Related Compound A (1 gram) from Sigma Aldrich/Merck/TCI Chemical is a sealed, amber glass vial. |
| Shipping | Shipping for Diclofenac Related Compound A (offered by Sigma Aldrich, Merck, or TCI Chemical) follows standard protocols for research chemicals. The compound is securely packaged to prevent leaks and contamination, labeled per regulatory requirements, and shipped with documentation such as safety data sheets. Temperature and handling precautions are observed if specified. |
| Storage | Diclofenac Related Compound A should be stored in a tightly sealed container, protected from light and moisture. Store at room temperature (15–25°C) in a dry, well-ventilated area away from incompatible substances. Follow specific manufacturer guidelines (Sigma Aldrich, Merck, TCI Chemical) and ensure proper labeling. Handle with care, using appropriate personal protective equipment to prevent chemical contamination or degradation. |
Competitive Diclofenac Related Compound A prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every manufacturer with a focus on pharmaceutical intermediates and reference standards recognizes the constant demand for clarity at the molecular level. Diclofenac Related Compound A falls squarely into this category. Over the past decade, many research labs, quality control groups, and formulation chemists have come through our doors seeking a reliable reference for this specific impurity. More often than not, their reason is grounded in regulatory pressure—health authorities point to the need for precise quantification of impurities, particularly in nonsteroidal anti-inflammatory drugs like diclofenac. At our facility, Compound A receives the same meticulous treatment as the active pharmaceutical ingredient itself. Our chemists emphasize purification, reproducibility, and a clear audit trail for every lot produced.
In the market, we have watched how standardization for reference materials sometimes leans on generic offerings. We do not subscribe to batch-blending or repackaging practices seen elsewhere. Every synthesis in our lab starts with internal controls that track origin, solvent quality, and reagent purity. Diclofenac Related Compound A is no exception. The typical model number reflects our internal batch system, ensuring each lot can be traced back through the entire production and analytical workflow. We subject each batch to thorough HPLC, LC-MS, and NMR analysis. Only those matching our established spectra and meeting a minimum purity threshold of 98.0% release for shipment.
Our roots in chemical synthesis stretch back decades. As a manufacturer, we do not see value in shortcuts. Each impurity reference is synthesized individually, handled under anhydrous conditions, and stored to withstand both temperature and humidity changes. The finished product leaves our facility after repeated identity checks. For Compound A of diclofenac, even a small drift in molecular integrity—be it a hydrolyzed group or trace racemization—draws out-of-specification actions. We routinely run both proton and carbon NMR, ensuring no extraneous peaks pollute the spectrum. A UV spectrum collected in methanol provides additional identity certification, and we archive results for every batch.
For those in analytical development or routine QC, the prime concern with a compound like this is its behavior under multiple detection methods. While vendors often confirm identity using one platform, we insist on confirmation across three or more analytical methods, including but not limited to: high-resolution mass spectrometry, dual-wavelength HPLC confirmation, and FT-IR analysis. Insight from years of process development teaches that trace-level contaminants not flagged by one instrument can easily slip into the analytical blind spot. By tightening our QC approach, our customers avoid surprises during compendial testing or worse, regulatory inspections.
The chemical industry often pushes either impractically small or unwieldy bulk batch sizes for working standards. Based on repeated conversations with analytical labs, we settled on packaging sizes that minimize repeated access and exposure—usually 10 mg to 250 mg. These formats support standard, stability, and spiking studies without the risk of repeated environmental exposure. Our experience shows that repeated thaw/freeze or atmosphere exposure drastically shortens the lifespan of impurity standards. Glass amber vials with PTFE-lined caps are the direct result of customer requests, not marketing jargon.
Many customers keenly observe the fine distinctions between related substances in the diclofenac family. Compound A, specifically, occurs as a prominent process-related impurity. While structurally similar to diclofenac itself, it contains a definitive group substitution easily detected with routine LC methods, and it expresses different retention times under reversed-phase conditions. In our hands, Compound A shows greater sensitivity to UV light and moisture than the base diclofenac molecule. Handling instructions and documentation delivered with every order flag these differences so analysts do not run into unexpected degradation or chromatographic shifts.
Over the years, regulatory authorities have intensified their focus on both the detection and quantification of impurities in finished drug products. The experience on the manufacturing floor teaches the same lessons—approximations and poor documentation result in regulatory issues and product recalls. We have responded by aligning our entire Compound A production with qualified person sign-offs at each stage. Each analytical report attached to a batch is more than a checklist. It reads as an audit story, showing inspection dates, method reference, instrument performance verification, and analyst identification. This goes beyond regulatory paperwork; it lets labs demonstrate due diligence during regulatory audits.
For our team, manufacturing Diclofenac Related Compound A offers more than routine compliance. The difference generated by chemistry-driven processes comes to light during method qualification and method transfer studies. Labs often share challenges around baseline noise, coeluting peaks, or drifting retention times. We offer Compound A in both certified and custom purity grades—these are not decorative labels—but reflect the real outcome of synthetic pathway optimization or an extra round of recrystallization. Care in drying, choice of crystal form, and consistent particle size shape the shelf stability and reconstitution performance. Labs running trace-level impurity quantification do not have time for ill-characterized standards or inconsistent purity lots.
Purity for Compound A is not merely a number on a label. We have seen firsthand how even sub-percent contamination can affect HPLC sensitivity or cause a method to fail intermediate precision testing. Our release specs land at 98% minimum by HPLC, and up to 99.5% for specialized lots. We send every batch out with the corresponding certificate, including a full chromatographic trace, batch-specific NMR, and a detailed impurity profile. This direct tie between analytical data and shipment avoids silent failures at the customer end. Solid impurity compounds—especially rarer reference standards—are where analytical reproducibility succeeds or fails in pharmaceutical development.
Much of the generic supply chain offers bulk materials that have passed through several hands and facilities before reaching the laboratory. As a direct manufacturer, we control every step—from raw material intake to lot-specific packaging. Each gram of Compound A has a batch number and full documentation available for audit. Internal traceability systems at our site prevent mishandling, cross-contamination, and relabeling errors. If a lab calls with a question about retention time drift or storage anomalies, our production chemists respond with detailed batch history, production logs, and analysis records. No layer of resellers stands between our science team and the analyst using the compound.
Most analytical method development is not plug-and-play. The labs we support with Compound A often face interference from excipient peaks or overlapping impurities. We make ourselves available for direct support—sharing reference chromatograms, solvent recommendations, and handling tips. For method transfer studies or ICH stability protocols, we supply extended COAs, calibration support documents, and re-testing on demand. Only direct manufacturers with a real synthesis capability can address these needs efficiently. Experience matters far more than a polished brochure. We have learned that supporting users this way closes the loop on analytical variation and batch-to-batch inconsistency.
Few things teach a manufacturer faster than process failures. With Diclofenac Related Compound A, we have refined our process over years—tuning reagent ratios, optimizing solvent choices, and validating cooling profiles. Every time a batch presented crystallization challenge or unexpected side-product, our team adjusted protocols and moved forward. Success today means fewer rejected lots, faster response times for urgent customer requests, and a tighter impurity profile in our own product. The hard-won knowledge from failures filters into both current batches and process documentation. Laboratories benefit from these incremental improvements, even if they never see the inside of a chemical reactor.
Customers often share outcomes after using Compound A—sometimes direct praise for documentation clarity, other times reporting chromatographic idiosyncrasies. We document every field report and often adapt our batch documentation or handling advice accordingly. When a customer flagged a slight shift in UV absorption profile due to a different solvent system, we reproduced the test, verified the outcome, and included additional solvent compatibility notes in every outgoing batch. This granular, constant adaptation comes only from owning the synthesis and monitoring the market’s real issues. Too many reference materials fail in final application because the manufacturer lacks feedback loops; we count on these improvements for our survival and reputation.
Disruption in global supply chains has made uninterrupted reference material sourcing a universal concern. By integrating vertical production with an on-site inventory buffer, we mitigate unpredictable demand spikes and transportation delays. Compound A stocks never reach critically low levels, allowing us to ship on demand for audit responses, short-notice formulation studies, or emergency compendial needs. Third-party trading platforms rarely back up late shipments or send replacement lots quickly—the liability lies with the buyer. Taking ownership of production and inventory, with no outsourcing or brokering, puts accountability firmly on our shoulders. For Compound A, that means our customers avoid costly method interruptions.
As organic synthesis chemists, our work with Compound A includes handling reactive intermediates and hazardous solvents. We have invested in on-site solvent recovery facilities, containment protocols, and worker exposure monitoring. These steps are not motivated by regulatory mandates but by daily experience with the hazards of process chemistry. Residual solvents receive direct analysis before a batch clears QA. Operator training, including correct use of PPE and spill management drills, cuts risk for exposure incidents and reinforces a culture of chemical safety. Transparent, repeatable processes not only give us clean product but keep our team safe in a demanding environment.
Partnering with labs over many years has taught us the difference between a one-off transaction and a long-term supply relationship. Customers of Compound A come back not for the label or the marketing, but because every gram received traces back to a consistent, responsive manufacturer. With each round of recertification or method transfer, we share primary production data, analytical details, and stability study results. If a specification needs to be tightened or a packaging request emerges, we adapt quickly—because we maintain real control over synthesis and packaging. This constant dialogue contrasts sharply with the static, secondary-market approach that delivers only what is on the shelf.
Research continues to push the boundaries in detection, quantification, and reporting of pharmaceutical impurities. As reporting thresholds tighten and analytical sensitivity improves, the relevance of rigorously produced standards like Compound A grows. We invest in new instrumentation, process analytics, and chemist training every year, not for marketing but to stay ahead of the curve. Collaboration with academic and industry partners brings insight into trending analytical challenges, new impurity profiles, and regulatory hot spots. Staying relevant in this field means adopting new techniques, expanding impurity panels, and never losing sight of the fact that our products anchor critical safety and efficacy work around the world.
Manufacturing Diclofenac Related Compound A is not about producing another catalog item. It is about bringing hard-earned expertise, a relentless focus on documentation, and real partnership with scientists and quality teams. Each step—synthesis, purification, analysis, and customer support—comes from a history of addressing chemical and practical issues head-on. Labs working with us find that every batch delivers traceability, consistent results, and clear support—because the team producing Compound A wakes up every day to meet these complex challenges. No substitutes exist for direct manufacturing knowledge; every analyst’s result ultimately depends on it.