|
HS Code |
996515 |
| Product Name | Dichloromethane (for HPLC) |
| Chemical Formula | CH2Cl2 |
| Cas Number | 75-09-2 |
| Molar Mass | 84.93 g/mol |
| Appearance | Colorless liquid |
| Purity | ≥99.9% (HPLC grade) |
| Density | 1.325 g/cm3 (20°C) |
| Boiling Point | 39.6°C |
| Melting Point | -95°C |
| Refractive Index | n20/D 1.424 |
| Water Solubility | 20 g/L (20°C) |
| Flash Point | None (non-flammable by conventional methods) |
| Vapor Pressure | 47.3 kPa (20°C) |
| Brand Examples | Sigma Aldrich, Merck, TCL Chemical |
As an accredited Dichloromethane (for HPLC) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Dichloromethane (for HPLC) is supplied by Sigma Aldrich in a 2.5L amber glass bottle with a secure screw cap. |
| Shipping | Dichloromethane (for HPLC) from Sigma Aldrich/Merck/TCI Chemical is shipped in secure, leak-proof containers compliant with hazardous material regulations. Packaging includes safety labeling and documentation per international transport guidelines. The shipment is handled by certified carriers, ensuring safe, temperature-controlled delivery with appropriate protective measures for laboratory and industrial use. |
| Storage | Dichloromethane (for HPLC) from Sigma Aldrich/Merck/TCI Chemical should be stored in a tightly closed, properly labeled container in a cool, dry, and well-ventilated area, away from sources of ignition, heat, direct sunlight, and incompatible substances such as strong oxidizers. Storage should comply with local regulations, and the chemical should be kept in a designated flammable chemicals cabinet. |
Competitive Dichloromethane (for HPLC) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every day in our plant, on the floor and in the control rooms, decisions shape the purity and quality of what ends up in your laboratory. Dichloromethane, sometimes called methylene chloride, comes off our lines as a clear, colorless liquid with a faint, sweet smell. Producing it isn’t as simple as running a batch and bottling what comes out of the reactor. To serve chromatographers who rely on HPLC, we take extra steps, pushing for purity levels where trace contaminants stay out of results and workflows don’t trip over invisible hiccups.
We built our process specifically for demanding HPLC applications, where organic impurities, trace water, and dissolved gases can throw off even the most careful method. In routine industrial uses, you might work with dichloromethane where the spec is flexible—paint removers, degreasing, adhesive manufacture—all fine with broad tolerances. Not for HPLC. Here, every batch tells a story about our discipline, our consistency, and our understanding of how tiny changes ripple through a system downstream.
Making dichloromethane for HPLC means more than beating a purity number printed on a label. We monitor every input, track lines for cross-contamination, and test batches using the same HPLC instruments found in the end user’s lab. Starting with high-quality chlorinated feedstocks, we refine through consecutive distillations under reduced pressure, washing with water and filtering out particulate matter. Our approach keeps non-volatile residues far below the strict thresholds set for chromatographic analysis.
We invest in extra gas stripping and molecular sieving to cut dissolved oxygen and water. Anyone used to running solvent-grade dichloromethane might have struggled with baseline drift or ghost peaks, especially when chasing sensitive analytes. Those days fade when the bottle holds what we just made in our facility, bottled under inert gas, in materials matched to preserve integrity. We don’t take cutting corners lightly; one slip shows up as lost time and squandered samples in your hands.
Technical specs for dichloromethane are often reduced to a rounded figure: 99.8% or greater. That figure means something different depending on where it comes from. Our focus stretches beyond the headline percentage. We target water content under 0.005%, trace non-volatile matter less than 0.0005%, and iron and other metals at or below detection limits. Every batch runs through final analytical verification. GC and HPLC scans allow us to look for background contamination—halogenated byproducts, non-volatile residue, or unexpected peaks.
We also screen for absorption at the lower ultraviolet range, since many users depend on baseline quietness under 220 nm to detect polar or small molecules. Over the years, feedback from analytical chemists and technicians has shaped how we set the triggers for intervention. Each bottle comes from vessels flushed and purged with nitrogen, then quickly capped to keep the sample free from moisture during storage and shipment.
On large commodity lines, the goal centers on volume and speed: run reactions, recover product, test for basic compliance, move out to industry. For us, working toward HPLC suitability means slowing down, introducing quality holds, testing more samples per batch, and accepting only what meets a tight set of acceptance criteria. Where a container-grade dichloromethane may contain traces of stabilizers or carryover from past runs, ours is made from clean lines, and every surface in contact with the solvent is washed down before production.
The packaging matters as much as the liquid. Over time, even the cleanest dichloromethane absorbs volatile compounds from air or leaches plasticizers if poured into the wrong polymer. We match the solvent’s reactivity with packaging materials, sticking with high-quality amber glass or chemically resistant polymers that showed no background in UV or GC analysis. Seals and caps are tested for vapor impermeability, not just durability during transport.
Many of our regular customers—pharmaceutical labs, food safety institutes, environmental monitoring bodies—don’t care just about purity, but about the absence of specific trace contaminants. They check for low nitrosamines, excluded stabilizers, and unwanted aromatic byproducts. Our protocols respond to that, keeping our information flow transparent from raw material intake to filling lines. Every certificate isn’t just a formality; it’s a logbook for a process we’ve optimized through trial, error, and dialogue with real users.
Anyone who has worked a line producing chlorinated solvents has met the challenges involved firsthand. Dichloromethane’s volatility means even a small leak becomes a workplace hazard, and if a valve or seal fails, moisture creeps in fast. Water, once dissolved, throws off HPLC baselines and damages columns. So we keep our storage rooms dehumidified, test storage tanks regularly, and purge lines with dry nitrogen before moving on. Regular calibration of analytical equipment keeps our checks reliable.
Sometimes a raw material shipment falls short on its own quality, so we run extra small-volume trials before blending into the main batch. If results don’t line up with what we need, we hold or reject. Each hour spent double-checking causes delays, but it saves headaches for customers who count on invisible consistency for their assays and calibrations. From the outside, it might just seem like another canister or drum of solvent, but for the applications we support, it feels more like part of the instrumentation itself.
The chemical industry faces changing standards. Over the years, authorities in Europe, the Americas, and Asia have tightened controls on solvent residuals, worker exposure, and environmental release. We’ve seen new test requirements pop up for previously unregulated compounds and must keep up to continue delivering a product that meets both local rules and international expectations. For HPLC professionals, compliance means more than a checkbox; trace impurities risk inaccurate or nonreplicable results in health and environmental testing.
Our plant keeps dedicated lines for HPLC-grade solvents, ensuring that neither cross-contamination nor undocumented process changes slip through. Documentation grows thicker as every batch is logged, and trend reports help spot issues early. We stay connected to regulatory bodies and update our protocols as shifts happen. Since regulations can differ by region, we make sure that every market’s product matches the tightest spec demanded anywhere. That means internal standards sometimes go beyond what the law writes, simply because feedback from advanced labs asks for more.
As manufacturers, we hear from analysts who notice the difference immediately. Standardgrade dichloromethane, even when labeled high purity, often leaves behind small residues or lets trace water accumulate. Every one of those variables leads to higher background noise, random peaks, or unstable baselines that eat up valuable time. When troubleshooting, nobody wants to begin by questioning the solvent; it’s the foundation for their results.
This feedback loop influences every process decision we make. Each tweak in distillation or purification became policy because it solved real-world issues: eliminated drift, removed unknown artifacts, or cut prep time for sensitive equipment. Users running pesticide residue analysis, trace pharmaceutical detection, or metabolite studies rely on our products to keep interference to a minimum—what you see in the chromatogram actually comes from the sample, not the bottle.
Reliable solvents mean fewer failed runs, less scrapped sample, and greater trust in the data. Research doesn’t restart due to unexpected contamination. For routine testing—validation runs, stability checks, method development—labs call for a level of reassurance that only comes when a manufacturer sweats the details at every step.
Each drum or vial reaches users because a team led the way through production, testing, and packaging. From engineers setting process models to technicians maintaining columns and filling lines, every hand on deck knows why the margins matter. We cross-train staff on both production and analytical testing, making every member part of the quality assurance process. Breakdowns and missteps hurt, but teams learn from the patterns and adapt.
Customer feedback feeds into this cycle—issues flagged in the field drive process changes and periodic reviews. Some labs request tighter chlorine residue limits, others track trace aromatics from years back and want them controlled below fresh detection limits. Every time, we respond by revisiting protocols, looking at emerging technologies, and collaborating with suppliers to dig into the origins of contaminants.
People switching from industrial or lab-grade dichloromethane to our HPLC grade often remark on its cleaner evaporation profile and absence of stubborn residue on glassware. Standard grades tolerate up to a few hundred ppm of water and minor organic contaminants carried over from broader-use runs. Our HPLC-grade bottles average well under 50 ppm water and keep residues below detection limits in common chromatographic tests. In a side-by-side test, the difference in chromatogram clarity stands out—the background remains flat, even at high sensitivity.
We reject blended recycled product for this grade; only fresh, carefully sourced raw materials go through our distillation stream. Storage always matters, too—minute leaks in lower-grade packaging add up over weeks, which is why our caps and seals match the solvent’s volatility. Even trace leaching changes the story, so our storage policy connects production with warehousing, looking for environmental controls and inventory turnover that keep out-of-spec product off the shelf.
Where standard-grade solvent might occasionally run with stabilizer additives, ours runs clean. Labs looking for fully blank baselines in mass spectrometry or UV detection methods see the difference, even between bottles sourced from different manufacturers. Over time, reputation grows when feedback keeps scoring consisitently high for reliability and consistency across batches, especially over long research campaigns or monitoring contracts.
No manufacturing process is perfect, and solvent manufacture feels these limitations daily. Water absorption, metal leaching, and contamination from environmental sources happen, even with best practices in place. Our response is constant monitoring—moisture analysis at multiple stages, in-line filtration checks, and frequent glassware testing. Some challenges come from the supply chain, especially raw materials and reagents. Our teams keep alternate suppliers on file and run onboarding tests before introducing a new source.
Some customers question aging in stock—how shelf life and storage affect solvent reliability. We rotate batches, maintain rolling inventory, and put use-by limits in place based on real storage studies, not just industry convention. Each storage site must provide clean, inert conditions, or we redirect stock before degradation happens. Regional climate control in warehouses cuts condensation risk, supporting consistent water content readings on outbound product.
The design of packaging plays its part too. Our engineering teams review trends in environmental exposure—how sunlight, atmospheric oxygen, or temperature fluctuations affect both product quality and vapor pressure. We already updated our drum closure systems twice as new data from storage sites and logistics partners highlighted subtle shifts in product stability. Every claim made regarding packaging or shelf life is tied to hands-on analysis, not broad assertions.
Many of our customers operate at the frontiers of analytical chemistry—they develop methods years before new standards reach the mainstream. Regular calls, lab visits, and data exchanges help us learn the pitfalls of emerging workflows. Those experiences translate into updated processing and filling standards, new test protocols, and expanded impurity screens. We never settle, since today’s peak-picking artifact might become tomorrow’s regulated impurity.
Lab analysts pointed to issues with light sensitivity, so we moved to full-amber glass for sensitive grades. Some flagged particular spikes in GC backgrounds after weeks of storage; our team adjusted the line filters and swapped out a gear lubricant that showed trace leaching in follow-up tests. Tiny changes, but they build confidence at the customer’s bench when every run matters.
Our technical support team doesn’t rely on scripts. They pull from years on the factory floor and real troubleshooting visits to customer sites. They know what can go wrong when the solvent prep falls behind—chromatography columns foul, detectors lose calibration, batches run late. By working hands-on with researchers, they help sharpen both our own process and our partners’ methods and documentation.
Buying direct from a manufacturer keeps the chain short, so traceability and documentation flow without interruption. Distributors and resellers often lose detail in the shuffle, blending product lines or providing incomplete batch histories. We keep every batch traceable to the hour of production, the operator, the storage conditions, and the associated QC logs. Our support teams understand both production limits and the practical realities of laboratory use.
It also makes custom needs possible—sometimes a research group wants ultra-low non-volatile residue or has limits for trace metals below industry standard for a year-long campaign. Only by controlling every variable—feedstock, purification, packaging, and distribution—can the product’s purity curve reliably hit those marks, month after month. Long-term relationships start with reliability, and ongoing dialogue keeps us adapting.
Occasionally, a shipment flags an issue on receipt—our logistics partners misroute, or a shipment experiences unplanned delays. We work directly with receiving labs to sample, retest, or replace, owning both delivery and follow-up. This isn’t marketing talk; our reputation and continued business depend on responsiveness. The benefit of working direct shines brightest under pressure.
Few solvents play as central a role in analytical chemistry as dichloromethane. Its properties—low boiling point, strong solvency, low UV background—allow for sample extraction, residue analysis, derivatization, and gradient elution across fields as diverse as pharmaceuticals and environmental science. With each use, risks of cross-contamination or sample loss remain. Our job as a manufacturer is to control those risks before the solvent even leaves our gates.
Feedback from end users drives home the significance of every procedural adjustment. For some, the freedom to evaporate solvent rapidly without leaving residue saves hours in routines. Others care about the safety improvements from low-odor product, or the reliability of batch-to-batch UV transparency needed for precision in pesticide screening. Bottles leaving our line carry forward not just a chemical, but a reputation built by thousands of hours of supervision, oversight, and adaptation to both customer needs and new analytical standards.
The labs using dichloromethane for HPLC need clarity, reliability, and honesty about what’s inside their bottle. No batch is perfect and no process static, but we carry forward the lessons of every run to make the solvent as close to invisible as possible for chromatography. By treating analytical precision as a practical goal, not just a spec sheet score, we keep moving closer to the ideal our users demand.