HS Code |
496057 |
| Chemical Name | cis-1,2-Dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl)ethene |
| Molecular Formula | C20H18N2S2 |
| Molecular Weight | 350.50 g/mol |
| Appearance | Yellow solid |
| Melting Point | 179-183°C |
| Solubility | Soluble in organic solvents such as chloroform and dichloromethane |
| Cas Number | 151923-16-9 |
| Smiles | CC1=CSC(=C1C)C(C(C#N)=C(C#N)C2=CSC(=C2C)C)=C |
| Purity | Typically >98% |
| Storage Conditions | Store in a cool, dry place, protected from light |
| Synonyms | cis-DTECN, cis-Dithienylethene dicyano derivative |
| Iupac Name | (1Z)-1,2-dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl)ethene |
As an accredited cis-1,2-Dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl)ethene factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | cis-1,2-Dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl)ethene is supplied by Sigma-Aldrich in a 100 mg amber glass vial, securely sealed. |
| Shipping | cis-1,2-Dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl)ethene is shipped in tightly sealed containers to protect from moisture and light. The packaging complies with chemical transport regulations. Handle with care, store at room temperature, and keep away from incompatible substances. Shipping documents include safety data sheets for regulatory and safety compliance. |
| Storage | Store **cis-1,2-Dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl)ethene** in a cool, dry, and well-ventilated area, in a tightly closed, light-resistant container. Keep away from sources of ignition, strong oxidizers, and incompatible substances. Protect from moisture and direct sunlight. Follow all standard laboratory safety protocols and refer to the manufacturer’s Material Safety Data Sheet (MSDS) for detailed storage requirements. |
Competitive cis-1,2-Dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl)ethene prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
In many years working alongside fellow chemists, we’ve seen the demand for molecular switches climb steadily. One compound that stands out is cis-1,2-Dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl)ethene, or as we call it in the lab, cis-DTE for short. This material doesn’t just straddle the line between organic synthesis and photonic innovation, it pushes new boundaries with every batch we create. Its chemical structure, braced by dual dicyano groups and highly methylated thienyl rings, delivers reactions you can track and qualify. We learned early on the real value emerges not from arbitrary purity claims, but from how the solid handles in practice—yielding consistent reproducible results time after time, regardless of the scale-up step.
A textbook might say cis-DTE serves researchers fine at purity levels above 98 percent, but getting there is more complicated than a certificate. Active research groups want predictability. Whether it’s a full luminescence study or kinetic analysis, the absence of oligomerization and polymer contaminants matters as much as percent composition. Our production lines focus on molecular-level detail—attenuated levels of residual sulfur, tight control over moisture ingress during final crystallization, and batch data cross-verified with both single-crystal X-ray analysis and multi-solvent NMR. Each step got reshaped by years of feedback, both in doctoral group emails and conference hallway conversations.
Our labs use a tailored purification process, refined under the guidance of synthetic and analytical chemists who understand how minute changes can throw off sensitive studies. Reactions are run under high-purity argon, not generic nitrogen, and each run gets monitored with UV-vis, FTIR, and TLC, with spot checks using LC-MS before isolation. No two syntheses behave identically at scale, so batch records include not just HPLC purity but also trace detection of possible positional isomers. Process validation relies heavily on feedback from those who run photophysical tests themselves, rather than just shipping samples out for someone else to quantify.
The first time we synthesized cis-DTE, we spent longer tracking evaporated solvents than adding methyl groups. Anyone who’s made gram-quantities of this molecule knows the challenges: control the order of reagent addition, maintain temperature gradients through glassware, and catch side-reactions before purification gets complicated. Over time, small accidents shaped protocol improvements—accidentally overheating during one trial led us to design better reflux monitoring. Environmental factors like seasonal humidity affected solid-state crystallization, driving us to install improved humidity controls in the line. We learned to log these operational quirks, so no small batch ever gets derailed by forgotten process adjustments.
Sticking to best laboratory practice isn’t about rigid adherence to a publication’s conditions. On large-scale reactions, actual yields and process times unmask hidden bottlenecks. Transparent SOP documentation—annotated with real production histories—lets younger technicians step in for challenging steps. Regular collaboration with academic partners, who first advanced this class of compounds, means we can benchmark our production techniques against both literature standards and actual usage in device fabrication.
cis-DTE stands apart from related diarylethenes thanks to its reversible photochromic properties under visible or near-UV irradiation. Users report sharp, clear switching behavior and notable photo-fatigue resistance—even after hundreds of cycles—making it a go-to in light-controllable switches, rewritable optical storage, and high-contrast optical memories. Unlike simpler dithienylethenes, the 2,4,5-trimethyl modification steers selectivity and switches on a practical timescale. We have customer stories from groups using this material in prototype polymer films, thin-film transistors, and even biological probes, where repeated photo-isomerization doesn’t lead to significant decomposition.
The dicyano substituents aren’t just structural ornaments. They draw the conjugated system into sharper focus, stabilizing both closed and open forms and shifting absorption bands into more application-friendly regions. This means users can tune irradiation to specific wavelengths, minimizing photodamage risk when integrating devices with sensitive substrates or in living systems.
In workshops and technical forums, many people ask how cis-DTE differentiates itself from more generic photochromic thienylethenes or commercially available symmetric diarylethenes. One recurring misconception is that all diarylethenes switch with the same speed and fatigue resistance—experience in production and in customer application proves otherwise. The methyl groups at positions 2, 4, and 5 increase solubility in organic solvents, so samples can be stored and transported without aggregation issues that can plague unsubstituted systems. This also simplifies solution processing in device fabrication.
From an operational point of view, switching quantum yields and photochemical reaction rates respond directly to these substitutions. Researchers have reported substantial differences in bistability and memory holding time when comparing this product to unsubstituted or benzo-annulated analogs. Our own QC team uses UV-irradiation studies to confirm not just photoactivity but also reversibility and longevity—properties not guaranteed with products synthesized under less rigorous conditions.
We also see clear differences in batch stability. X-ray powder diffraction, run periodically on retained samples, confirms the absence of polymorphic phase transitions under normal storage—a feature that holds practical importance for labs building device prototypes that require weeks or months of development. Analytical records document how the dicyano groups suppress unwanted oligomerization or cross-polymerization, making the compound more predictable in both solution-based and immobilized states.
Trust in molecular-level claims needs evidence. We don’t just rely on batch data to show reliability—the real test comes from field feedback. Labs that purchase cis-DTE for advanced optical data storage experiments often return to us for further supply because they’ve validated performance over the course of hundreds or thousands of switching cycles. Our support doesn’t end at the shipping dock. We routinely provide spectroscopic characterization reports, walk-throughs of prior batch performance, and expert consultation when users scale up to device-level integration.
One particular research group, working on tunable filters for telecommunication hardware, shared test data showing absorption maximum reproducibility within 3 nm over multiple synthesis batches. This matches our lab data, where absorption in solution and crystalline phases stays inside tightly defined bands. If a sample under-performs during user screening, we consult with their analytical chemist to identify if the issue relates to process changes, unforeseen contaminant introduction, or operational conditions.
This ongoing critique and refinement process means every improvement in our workflow gets validated both in-house and with trusted external labs. Analytical profiles, from NMR to MALDI-TOF, provide transparency. We encourage users to request detailed chromatograms, not just summary certificates—open dialogue leads to the next round of process optimization.
Synthetic diarylethenes like cis-DTE come with their challenges, from sensitive reaction intermediates to batch-scale reproducibility. Our experience shows that troubleshooting small shifts in product yield or purity begins long before analytical testing—good chemistry depends on diligent process monitoring and swift problem-solving during synthesis itself. We track air and moisture exposure scrupulously and employ closed-system transfer when scaling reactions beyond several grams. Modified distillation columns help us separate volatile side products before they interfere downstream.
Waste minimization rises in importance as global sustainability standards tighten. This compound’s synthesis generates byproducts we recover and recycle wherever possible—our team designed custom separation protocols for solvents and auxiliary agents, letting us reduce both costs and environmental impact. Our senior chemists hold regular line audits to confirm waste reduction targets and keep operations within local emissions limits. New purification media developed in partnership with university researchers allow more effective removal of trace-colored impurities, eliminating product contamination without resorting to extensive silica waste.
Quality control relies not just on instrumentation but on the experience of hands-on bench chemists. They spot color shifts in purification fractions, track microchanges in TLC retention, and spot the tell-tale symptoms of ingredient degradation. Automated equipment can monitor broad parameters; skilled eyes and careful hands catch subtler issues early. All these observations funnel into process-wide adjustments each production cycle.
Work at the chemical bench thrives on communication. We maintain open lines with research labs and industrial pilot users, sharing not just batch test data but technical insights from previous challenges. This product’s evolution came from hundreds of collective hours collecting, analyzing, and responding to field feedback.
Sharing knowledge both internally and externally generates concrete improvements. For instance, several years ago, a user noted recurring difficulties dissolving early batches in their polymer matrix of choice. We adjusted final drying stages, swapping to rotary evaporation and lower-temperature vacuum drying, which reduced microaggregates and kept post-purification solubility constant. This kind of change doesn’t show up in a certificate but makes all the difference in end-use.
Our chemists also consult directly on system integration, advising on irradiation protocols or stability testing methods that fit the user’s setup. Each case brings unique operational needs. Some require special solvent blends for casting; others want documentation of long-term storage tests. Being available and responsive at these operational touchpoints increases overall project efficiency and result consistency.
Continuous improvement also means inviting critiques. When something fails—a photoreversibility test or stress aging experiment—we treat the event as a data source. Detailed user reports loop back into SOP revision, raw material selection, and worker training adjustments. Each incremental improvement gets documented so the next batch, and the next user, benefits from accumulated experience.
Product consistency grows from openness. We do not market flashy “one-size-fits-all” guarantees. Instead, batch validation rests on actual performance—spectra, chromatograms, and device-level test feedback. Our sales process includes access to full test reports, and we encourage repeat buyers to request additional testing or samples from parallel batches. It’s not enough to say a batch rates above 98 percent by HPLC; each purchaser deserves corroborating proof, including photochromic switching assays and endurance test data.
Trust is also built by honoring operational constraints. Device developers cannot afford performance drift across material lots, nor sudden changes in process recommendations. We notify customers ahead of time about upcoming protocol updates, new analytical methods, or raw material sourcing changes, so process engineers can validate updated batches before large-scale utilization. When new analytical standards improve detection of ultra-trace contaminants, we upgrade lab equipment and share the resulting baseline assays.
Meaningful quality assurance echoes throughout the company: QC reports always include detailed run histories, with technician notes and measured variances. Open archiving means any authorized lab can review retained samples, cross-check published spectra, and confirm manufacturing consistency. Earning trust takes transparency and a shared commitment to long-term reliability.
Science pushes boundaries not by reaching for flashy innovation, but by quietly refining proven tools—compound by compound, batch by batch. Our approach with cis-DTE reflects this attitude. We seek out feedback from both established industry players and ambitious researchers working at the cutting edge of optoelectronics, nano-scale engineering, and bio-compatible materials. Our innovations focus less on chasing outright novelty and more on maximizing utility—solubility in emerging media, stability in harsh conditions, and performance under repeated operational stress.
Future applications keep evolving. We see demand shifting towards integration in hybrid organic-inorganic devices, combinatorial libraries for material discovery, and embedded molecular switches for information storage at the molecular scale. Each advance demands careful characterization—not just of final product but of every intermediate along the pathway. Our team stays active in technical networks, contributing assay findings and sharing best practices, so the broader community benefits from collective learning.
As technical barriers rise—higher switching speeds, narrower absorption bands, more demanding operational environments—our job pivots to helping researchers and engineers understand molecular limitations and practical workarounds. We invest directly in analytical upgrades and partner with developers exploring new end-use scenarios. Continuous dialogue between bench and user shortens development timelines and makes our chemistry more accessible, reproducible, and impactful.
Making cis-1,2-Dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl)ethene isn’t an exercise in rote synthesis. Our process relies on deep chemical knowledge, hard-won experience, and an ongoing commitment to improvement and collaboration. Every shipment leaves our lines tested far beyond minimal specifications, rooted in direct user feedback. We don’t sell molecules in isolation; we support ongoing innovation in data storage, sensing, switching, and more. For every gram rigorously purified, tested, and shipped, a team stands ready to troubleshoot, explain, and engage—moving chemistry forward one challenge at a time.