HS Code |
597492 |
| Product Name | Chrysin |
| Cas Number | 480-40-0 |
| Molecular Formula | C15H10O4 |
| Molecular Weight | 254.24 g/mol |
| Appearance | Yellow powder |
| Melting Point | 285-287°C |
| Purity | ≥97% |
| Solubility | Insoluble in water, soluble in DMSO and ethanol |
| Storage Temperature | 2-8°C |
| Synonyms | 5,7-Dihydroxyflavone |
| Catalog Numbers | Sigma-Aldrich: C80105; Merck: 480-40-0; TCI: C3021 |
| Ec Number | 207-549-7 |
| Pka | 7.44 (at 25°C) |
As an accredited Chrysine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Chrysine from Sigma Aldrich comes in a 5g amber glass bottle, sealed with a screw cap and labeled with product details and warnings. |
| Shipping | Chrysine from Sigma Aldrich/Merck/TCI Chemical is typically shipped in secure, tightly closed containers under ambient conditions. Packaging ensures protection from moisture and contamination. Shipments comply with relevant chemical transport regulations, including appropriate labeling and documentation. Handle with care during transit and storage according to the Material Safety Data Sheet (MSDS) instructions. |
| Storage | Chrysine (available from Sigma Aldrich, Merck, and TCI Chemical) should be stored in a tightly closed container in a cool, dry, and well-ventilated area away from direct sunlight and incompatible substances such as strong oxidizers. Store at room temperature, away from moisture and heat sources. Proper labeling and adherence to local regulations for chemical storage are essential for safety and product stability. |
Competitive Chrysine prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
In the field of advanced synthesis, few flavonoids draw more interest than chrysine. We take an active role in the quality progression of every gram we produce. With decades spent resolving issues that arise during scale-up, our plant embraces rigorous controls with each lot. Our chrysine catalogue model, C109, grows out of the actual needs in biochemical research and supplement manufacturing, not a catalog made for labeling convenience. What matters here is what is truly inside the drum.
Chrysine—also called 5,7-dihydroxyflavone—stems from a precise synthesis. Each batch must present a snow-white to pale yellow crystalline powder, free of any visible contamination. We maintain minimum purity of 98% by HPLC, but in reality we push higher, since each run tells its own story amid temperature shifts and solvent quirks. Residual solvents are tightly monitored, with our in-house GC ensuring no detectable methanol or toluene traces. Moisture sits well below 2%, measured by Karl Fischer, since clumping causes more headaches in downstream blending than almost anything else. Particle size sits between 30–80 mesh, providing steady behavior in both blending and tableting. We avoid broad claims about “universal compatibility” because the best blend comes from matching the right mesh with real end-use trials in a specific granulation process.
Chrysine pops up often in sports nutrition, but our core focus leans toward technical applications—mainly research, assay development, and metabolic pathway analysis. Direct inclusion in supplement formulas has drawn debate from the scientific community; our internal R&D keeps a close watch on both the promise and pitfalls. For research teams, the challenge is consistency—all that matters is a repeatable spectral fingerprint and trouble-free dissolution. In metabolic enzyme and transporter studies, inconsistent material skews results and burns time. Our broader-eyed view means we keep internal reference standards for every shipment and run periodic degredation checks to spot any slow shifts in material properties.
Many in the market tout high-purity chrysine, but few consider the silent impact of related flavonoid impurities. When a 0.5% impurity comes from unknown or uncontrolled sources, that’s when trouble starts. In HPLC trace work, the wrong isomer or an unreacted starting material derails both analyses and bench formulations. Our plant follows a crude isolation step, with a second recrystallization—costly in yield but necessary in the long run. GC-MS monitoring picks up trace oxygenates and polyphenols left from the extraction solvent. No single machine can pick up everything, so we compare results across different analytical clubs. Our production team knows that specs on a certificate are only as useful as the trust our clients place in our real control. We don’t push for “absolute” purity, but for transparency and technical support. With every order, we keep chromatograms available for review and provide samples on request to reduce surprises down the line.
After years of making and testing chrysine, a few differences stand out. One comes from the way we dry our material. The last solvent off is not just about getting to low moisture—it avoids cross contamination and keeps the powder free-flowing. We go for low pressure drying at moderate heat, since temperature shocks have been known to trigger polymorphic changes in the flavonoid baseline. Some producers grab for speed to boost their yield, but crystal structure matters as much as any HPLC curve. Storage trays are cleaned after every use, and old batches never interact with new ones. This is more than a paperwork claim—we take physical swabs post cleaning, not just rely on detergent flushes, because trace buildup can act as invisible seeds for next generation contaminants. The bottom line is less about marketing and more about directly stopping surprises that tend to pop up months later in a client’s new blend.
Chrysine’s chemical backbone differs from flavonols such as quercetin. While quercetin packs in five hydroxy groups, chrysine keeps only two—both positioned in a way that shifts its stability and solubility. In practical plant processing, that means the crystallization behavior diverges. Quercetin often drops out in rough, irregular platelets, while chrysine prefers sharp, needle-like crystals, making sieving more predictable and limiting dust. Dissolution varies as well; chrysine shows limited solubility in water, but in mixed solvents, the rate of dissolution steps up notably. This fine control helps material scientists target solubility constraints when working in solid dispersions or inclusion complexes. With catechins, conversion routes get tricky—unlike soft, easily oxidized catechins, chrysine’s robustness helps keep its color and odor stable during tableting or encapsulation.
We have experience with how warehouse humidity levels shift through the seasons and find ways to deal with caking, even when drums seal tight. Periodic humidity spikes in the rainy season change handling strategy: we rotate drums, avoid stacking too tight, and sample for moisture uptake more often. Most so-called warehouse “solutions” don’t survive a real-world environment, so we built out humidity logging with alerts tied straight to both our operations team and our QC desk. Tableting trials taught us that minor tweaks—like switching antistatic liners—can improve downstream process yields by 1–3%. Clients often share feedback with us on unexpected granule compressibility issues, which we resolve together by walking through every node in the production chain. We see ourselves less as a supplier and more as a collaborator in making sure every downstream step lines up.
Data integrity grows from doing the work right, not just piling up certificates. Every batch of C109 tracks full traceability—date, shift, all reagents and operators. We don’t erase outliers from the record; QA teams see everything, and external audits happen more than once a year to challenge our controls. Batch stability checks run for at least six months, with samples stored at different temperatures, not only ambient. Real-world exposure to light, oxygen, and varying temps shows how chrysine survives outside the best-case scenario. We record not just the “big” numbers—purity, loss on drying—but all side readings, tracking any minor spike for future investigation. This is not because we love paperwork but because our customers take a real risk when blending compounds into expensive R&D projects or supplement lines.
Mixing chrysine into excipients takes skill beyond just dumping powder in a mixer. Our plant staff has spent years watching what happens when powder blends fight lubrication or when static causes material losses. We never promise instant blending “solutions”; we dig into what works batch by batch, focusing on how the flavonoid interacts with different carriers. During pilot runs, we test direct compression and wet granulation—seeing firsthand any impact of moisture or blend time. For clients mixing in plant extracts or botanicals with delicate aromas, the mild odour profile of our controlled-dried chrysine reduces sensory off-notes and formulation headaches.
In years past, minor shifts in starting material quality sent shockwaves down the production line. With chrysine, the impact of residual metals and trace byproducts shows up in color and flow. We now actively screen for iron, copper, and lead at low ppm thresholds, since even sub-visible contamination sometimes turns up as a problem during final QC or customer audits. Hard lessons taught us to avoid sliding along “global limits” but instead, to focus on what our downstream partners experience. Instead of trying to match paper specs to theoretical limits, we lean on real user feedback. Changes to batch drying parameters or slight shifts in mesh size get flagged internally, so formulation teams can adjust and avoid nasty surprises.
Chrysine emerges in both reference standard and process intermediate forms. Our technical clients—especially those developing detection assays and reference libraries—need not only purity but also stability under repeat dilution and long-term storage. Flavonoids like chrysine degrade under light and high humidity, which is why we package in light-proof, double-bagged drums. Cold-storage shipment is always available to reduce breakdown during customs holds or long freight cycles. Our years making reference-grade chrysine taught us to calibrate against primary reference standards every six months. Every analytical report gets peer review upstream of releasing material; spectral and chromatographic data come not from automation alone but from staff who know what an off-peak looks like at a glance.
Our site can push out chrysine in modest kilo runs up to multi-ton contracts. As batch size grows, reproducibility matter more—small craft batches easily cover up for human error, but real manufacturing at scale exposes weak links. We run entire process trials before committing to a new kilo-scale launch, since even slight tweaks in vessel geometry or agitator speed shift impurity profiles. Any new project starts with detailed risk assessment and open client discussion. Logistics never gets left as an afterthought; temperature tracking starts at the loading dock, not the border crossing. Years of pushing through customs and shipping delays taught us that keeping a few emergency lots ready can save a critical project timeline.
Chrysine production, like any chemical synthesis, generates solvent and waste. We take pride in a closed-loop solvent system that recycles nearly 85% of extraction solvents, steadily lowering both costs and environmental impact. Process engineers worked through every step to minimize hazardous waste; distillation column upgrades reduced our hazardous output by almost 40% in the past five years. Community trust hinges on honest environmental reporting—site emissions and effluent results go straight to the public database, as local inspectors perform unannounced checks. Wastewater is pretreated on-site before joining the municipal flow, with discharge metrics shared in real time with our downstream neighbors.
Standing still means falling behind in this business. Each year brings new customer challenges, regulatory changes, and advances in analytical technology. We invest in both staff training and equipment upgrades—a new UPLC station entered our QC lab last year, cutting analytical turnaround times and shrinking solvent use. Staff rotate on secondment with leading formulation labs, returning with hands-on tweaks that shave days off scale-up timelines. We prioritize cross-team feedback cycles, bringing quality, plant, and R&D together at the planning stage rather than siloing staff. One recent process shift, suggested by a plant technician, increased recovery rates by 8% over the past three quarters. Small wins build over time—there’s no magic bullet, just consistent action.
New rules come almost every month. We track evolving expectations on heavy metals, pesticide residues, and allergen declarations. Recently, regulatory bodies in both North America and Europe increased scrutiny of process solvents in dietary ingredient production. Our teams produce in-depth reports—solvent use, final residues after drying, unexpected byproducts—and share information in standardized formats for both industry and regulator review. Rather than react at the last minute, we keep early-stage regulators in the conversation, gaining insight into coming inspection targets. Our QR code labeling links every drum to its analytical archive—no fancy app needed, just instant, transparent access for any inspector or formulation partner on site.
Technological frontiers move quickly in the flavonoid space. Some of our partners pursue encapsulation in cyclodextrins, others look for smart delivery via nanoparticles or biodegradable films. We keep a small R&D pilot line ready to try client ideas on short notice, testing how chrysine holds up under heat, pressure, or aggressive encapsulation. Every season, feedback from formulation teams feeds back into our mainline process, often demanding tighter moisture targets or finer mesh cuts. The best improvement suggestions often come from a user halfway around the world. As tech pushes forward, our aim remains: provide material that meets both the exacting standards of leading researchers and the needs of forward-looking supplement developers.
Chrysine fills a narrow but fast-evolving set of niches for chemists, nutritionists, and technologists. Our job is not just to provide a drum of powder, but to anticipate and fix the small sticking points—whether that’s streamlined blending, reliable data, or project-delivery timelines. From our point of view inside the plant, decisions about washing procedures, drying parameters, or even simple record-keeping can define whether a batch succeeds or falters. End users don’t see the process, just the consistency of result—and after years of hearing both praise and complaint, we know that’s what really counts.
Our chrysine model C109 stands on a foundation of continuous learning and real accountability. We invest behind the scenes, not just in machinery or certificates but in the cumulative know-how that comes from thousands of kilos shipped and tested worldwide. As new challenges and technologies reshape the requirements for flavonoids, we move with them, committed to tracing every gram back to its origin and every blend forward to its ultimate performance. We welcome direct questions and feedback, as each inquiry pushes us to deliver better in both product and partnership.