West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Carbonic Anhydrase

    • Product Name Carbonic Anhydrase
    • Alias CA
    • Einecs 3-006-537
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    551398

    Product Name Carbonic Anhydrase
    Synonyms Carbonic Dehydratase
    Cas Number 9001-03-2
    Ec Number 4.2.1.1
    Enzyme Class Lyase
    Molecular Weight Approx. 30 kDa
    Source Bovine erythrocytes
    Form Lyophilized powder
    Activity ≥2000 units/mg protein
    Storage Temperature -20°C

    As an accredited Carbonic Anhydrase factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Sigma Aldrich Carbonic Anhydrase comes in a 100 mg amber glass vial, sealed with a blue cap and detailed product information label.
    Shipping Shipping for Carbonic Anhydrase from Sigma Aldrich, Merck, or TCI Chemical typically requires temperature-controlled packaging, as the enzyme is sensitive to heat. It is dispatched in insulated containers with coolant packs and shipped via express courier to ensure stability and maintain product integrity during transit. Safety documentation accompanies each shipment.
    Storage Carbonic Anhydrase from Sigma Aldrich, Merck, or TCI Chemical should be stored at -20°C in a tightly sealed container, protected from light and moisture. Avoid repeated freeze-thaw cycles. Store in a dry, well-ventilated area, away from sources of contamination. Always refer to the specific product’s safety data sheet (SDS) for detailed storage and handling instructions.
    Free Quote

    Competitive Carbonic Anhydrase prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Introducing Carbonic Anhydrase: Reliable Performance for High-Demand Applications

    In our years manufacturing biochemical catalysts, we’ve worked closely with teams across pharmaceuticals, diagnostics, food and beverage, and ecological research. These collaborations taught us that the name on the bottle carries weight only if the results in the lab and on the production line meet tough, real-world expectations. Carbonic anhydrase—one of the key enzymes driving critical hydration and dehydration reactions—usually appears in one of two stories: either as a vital research tool or as the backbone in industrial bioprocesses where the stakes run high. Each environment asks something different from the enzyme, and we design with that in mind.

    We’ve been producing Carbonic Anhydrase Model CA-104 for years, building protocols by following industry research, then testing batch after batch for consistency. Most people who use it want more than enzyme—people want guarantees about purity, reproducibility, and technical support when a process or reaction doesn’t go as planned.

    Our Approach to Production

    Every production run starts with strain maintenance and selection. We grow the original microbial strains under closely monitored conditions, choosing carbonic anhydrase isoforms best able to handle environmental and substrate extremes. After harvesting, we purify using column chromatography that’s been optimized for high yield and low denaturation risk. Many manufacturers push for higher throughput at this stage with shortcuts, but we maintain temperature controls and buffer ratios that keep the protein active across a broader pH range.

    Standard lots come with SDS-PAGE profiles and activity validation—our daily QC covers specific activity (Wilbur-Anderson or CO2 hydration units/mg)—since practical performance beats theoretical purity every time. Based on customer feedback, we enhanced filtration to keep particulate matter below 2 µm and monitored endotoxin levels for sensitive diagnostic and in vivo uses.

    Specifications and Batch Consistency

    Average activity for CA-104 lands at 750-1200 Units/mg protein, with actual numbers posted on every release report. We ship powder form unless requested otherwise, as most users reported fewer handling issues and longer shelf life when lyophilized. Protein content runs above 95% as verified by HPLC, so there’s less batch-to-batch drift, especially for labs running comparative trials or scale-ups. We see that reproducibility across bottles is critical; one change, even a subtle one, scrambles entire downstream workflows.

    Shelf life from our plant ships at 24 months ambient, best kept at 2-8°C—although we have customers in low-resource settings who report stable function for over a year without refrigeration. For those who operate in extreme climates or variable humidity, we run stress simulations and provide real reports upon request. Trace elements and stabilizers follow our ‘no mystery ingredient’ policy: only what is publicly listed, without proprietary filler components or risky preservatives.

    Carbonic Anhydrase and Its Main Uses

    Most purchases head to biomedical labs developing carbon dioxide sensors or filtration systems. Others end up in bioreactors, polishing off the last traces of CO2 after fermentation, or prepping samples for blood chemistry testing. Enzyme substrates and inhibitors provide a measurable response, making quality especially crucial for diagnostic application. Any drift changes the outcome, and we rarely see two clinical runs with identical sample loads. Researchers requested CO2 hydration activity to stay consistent well above room temperature, and we scale up our buffer optimization for each new batch to deliver on that.

    Companies working on carbon capture and sequestration came to us looking for large-batch delivery of enzyme suitable for pilot-scale bioreactors. Many use carbonic anhydrase to drive direct air capture, accelerating natural reactions to fix CO2 into bicarbonate. In the food sector, some groups use it for monitoring dissolved CO2 during carbonation; every part per million counts for quality control. Plant physiology studies rely on it for CO2 assimilation tracking—a small detail, but each field brings unique sample pressures that generic enzyme manufacturers often overlook.

    Comparing to Other Carbonic Anhydrase Products

    Over the years we’ve tested competitors, both domestic and international. Several products claim high specific activity or advanced stabilization. Those often rely on peptide modifications or carrier-affinity conjugates. In actual use, these modifications can interfere in some assays or scale-up procedures where cross-reactivity or denaturation matters. We stick with wild-type sequences for CA-104, limiting processing steps to avoid overengineering. Customers who swapped from modified products to our model have shared reports showing fewer signal artifacts and gentler downstream purification steps.

    Some suppliers send carbonic anhydrase with high carrier content or as liquid, promoting convenience for those who want to skip reconstitution. We’ve found powders, with paired technical notes for optimal resuspension, best preserve enzyme activity and avoid shipment-induced degradation. Our batches consistently rank higher on mass spectrometry audits for host protein remnants and unwanted small-molecule contaminants. Larger companies working with GMP processes need certificates attached to every shipment, and we produce detailed, audit-traceable documentation without “gaps” in traceability that are common for resellers or traders.

    Technical Support and Collaboration

    Meeting customer needs goes beyond simply shipping product—we walk through assay development, troubleshoot batch reconstitution, and even adapt enzyme lots for niche protocols. Last year, a diagnostic group flagged a sensitivity drop at low CO2 concentrations; our team traced it to a buffer additive, then customized a side-production run stripped of that component. In industrial setups, we worked with engineers to optimize continuous CO2 scrubbing by adjusting ionic strength during rehydration. This feedback loop, rare among mass producers, shapes every future production plan and eliminates recurring problems down the line.

    We keep all records accessible, with enzyme sequence, batch origin, QC tests, and safety details documented. Whether a group needs additional CO2 hydration units per milligram or tighter contaminant control, communication remains direct between users and biochemical engineers on our floor. This transparency responded directly to clients’ early complaints about vague or unhelpful documentation.

    Detailing Benefits for Industry and Laboratory

    Clients in medical testing labs want more than a simple catalog entry—they require high control of background signals to ensure patient results remain unchanged. Early feedback told us that even single-point variances in enzyme background would alter outcomes in metabolic assays. Drug discovery teams, on the other hand, frequently use carbonic anhydrase inhibitors as screening compounds. Fluctuating enzyme activity made their results less reproducible, which led us to tighten our production windows and QC points. On large-scale industrial projects, the priority turns to stability and clear documentation for scale-up and regulatory filings.

    In ecological monitoring, scientists need enzyme stability despite shifting field conditions—a setting manufactured proteins often fail. Field kits using our CA-104 sustained activity after repeated freeze-thaw cycles, so data quality didn’t drop partway through a long project. No batch is ever “bronzed” as finished until we’ve run multiple durability and cross-reactivity tests. Testing is costly and time-consuming, but when you receive results, you aren’t left wondering whether the enzyme or the method failed.

    Challenges in Manufacturing Consistent Carbonic Anhydrase

    Making consistent enzyme involves risk at every step. Live cultures drift genetically over time—an ignored point for traders, but major manufacturers handle this with careful seed lot documentation and periodic strain sequencing. During purification, minor changes in buffer composition or temperature shift can scramble activity, so our team keeps strict logs and tunes process controls based on both outcome and day-to-day measurement. Seasonal water quality or even lot-to-lot plasticware variance can play a role. Only by tracking every variable and sharing these results with users can problems be solved before they hit process scale.

    Sometimes, the unexpected happens: raw ingredient shortages, equipment downtime, or transport issues slow timelines. We keep a buffer in supply to avoid running clients short, but in case of disruption, open communication and advance notification give users time to adjust schedules or protocols. We’ve learned the importance of over-communicating during these situations—being up front builds trust for long-term partnerships, more than any sales discount or glossy marketing promise.

    Improvements in Quality and Performance

    Continuous improvement forms the backbone of our production. After collecting complaints about particulate load in early batches, we invested in higher-grade filtration and better centrifugation to drop contamination rates by over 90%. Lab reports from customers prompted us to recalibrate our protein determination technique, shifting from UV to BCA quantification for higher accuracy. Product stability became a key focus after seeing some end users working in remote locations. At their request, we tested and improved lyophilization parameters, then supplied targeted advice for field reconstitution based on hands-on testing rather than theoretical models.

    We work closely with researchers who want to modify or adapt enzyme performance. A group exploring biofilm regulation needed a CA with different pH stability—they outlined their requirements, and our team experimented with buffer formulations and storage regimes until the results matched their protocols. No generic solution matches the resource-intensive approach of bench-to-production collaboration, but the outcome consistently supports the specific needs of high-stakes research and advanced industrial uses.

    Ensuring Regulatory Compliance and Safety

    Food and pharmaceutical sectors require full traceability, allergen risk mitigation, and detailed impurity profiles. Our record-keeping procedures span from raw material sourcing to lot release, including full documentation of solvents, disinfectants, and process interventions. Monitoring for microbial and endotoxin contamination, as well as heavy metal content, follows methods compatible with US and EU pharmacopeia. Risk of mislabeling, a problem for companies repackaging bulk enzyme, drops dramatically when production is handled as a closed system by our trained staff.

    Our technical staff are enrolled in continued education, keeping up to date with changes in global regulatory expectations. If research uncovers new risks or restrictions, we re-examine existing processes or reformulate to keep customer work uninterrupted. Support for filing regulatory documents and third-party audits comes standard; the reality in this space is that only manufacturers with complete visibility from fermentation to shipment can stand behind their compliance statements.

    Addressing Bottlenecks in Downstream Use

    One of the biggest sources of frustration stems from failed assays caused by impurities or low enzyme activity. We check with users after every order to gather data on finished product use cases. Reports of inconsistent performance, clogging during reconstitution, or detection of contaminants feed directly into the upgrade cycle for our lines. Enzyme “activity drift” frustrates clinical teams who require tight response windows. In response, our entire process runs under strictly controlled and inspected conditions, documented from the moment a new lot starts to the final stability check.

    We also field requests for custom concentrations or buffers designed for niche applications. A fermentation facility needed a robust, salt-tolerant enzyme; we reformulated buffer content, added stability tests, and shipped tailored documentation afterward. These workflows take time and transparent communication, but they prevent more costly failures at scale. We keep feedback lines active, reviewing all post-delivery reports internally so that minor annoyances never grow into repeat issues.

    Continuous Partnership and Real-World Problem Solving

    Many of our partnerships began with users testing competitors’ products, only to run into drift in enzyme activity, incomplete technical information, or inconsistent support. Our model supports open dialogue, providing access to production and QC data upon request. New or unusual application? We welcome technical deep dives to adapt process steps. Experience taught us that solving the right problem at the source keeps users productive—and loyal.

    Some industrial teams flagged foam stability issues in carbonation monitoring, which set off a line of inquiry in our QC group, ultimately leading to a process fix benefiting all lots. We value these connections and use every report to strengthen both customer trust and product reliability.

    Future Developments and Industry Trends

    Carbon utilization and environmental sustainability have become driving forces for enzyme engineering. New capture techniques—including membrane reactors and hybrid catalytic cycles—require ultra-stable carbonic anhydrases that tolerate cycling across pH and temperature shifts. In response, we partner with academic and industrial teams to develop next-generation strains and purification techniques offering both reliability and scalability.

    The future looks toward carbonic anhydrase fitted for bioprocessing in unconventional conditions, with minimal cross-reactivity and broad tolerance. We continue to keep one foot in the lab—open to user requests—while investing in technology that increases control and reduces sources of error. Quality improvement isn’t a project with a finish line; it’s the heart of every run, every test, and every relationship built with partners relying on CA-104.

    Why Manufacturer Experience Matters

    Working from the production side, we see issues on the line long before they appear in the lab—a perspective direct users rarely experience. We know which steps bring risk for contamination or denaturation and act to mitigate them. Traders or resellers focus on price and rapid delivery, often at the expense of detailed process control, stable supply, or traceable documentation. Our user base stretches from the simplest laboratory bench to continuous-process carbon capture, with each depending on the unbroken reliability that only direct, accountable production affords.

    Making carbonic anhydrase is as much about building a support network as producing protein. That means listening to critical feedback, adapting process and product to fit diverse, changing needs, and responding to the realities of research and industry alike. Our users depend on complete and correct product every time—with performance aligning precisely to their demanding protocols. Every day in the plant, every conversation with a researcher or engineer: that’s where value is grounded, and that’s how we contribute to every advancement that depends on this enzyme.