West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Bucladesine Sodium Salt

    • Product Name Bucladesine Sodium Salt
    • Alias DBS
    • Einecs 252-266-1
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    994642

    Name Bucladesine Sodium Salt
    Synonyms Dibutyryl-cAMP sodium salt
    Cas Number 36247-13-7
    Molecular Formula C16H25N5Na2O8P
    Molecular Weight 517.35 g/mol
    Appearance White to off-white powder
    Solubility Soluble in water
    Storage Temperature -20°C
    Purity ≥98%
    Use PKA activator; cell-permeable cAMP analog
    Inchi Key AGSLNRTMKKJJBU-UHFFFAOYSA-M
    Pubchem Cid 441399
    Melting Point No data available
    Stability Stable under recommended storage conditions
    Canonical Smiles CCCC1=NC2=C(N1)N=C(NC2=O)N[C@@H]3[C@@H](O3)COP(=O)(O)O.[Na+].[Na+]

    As an accredited Bucladesine Sodium Salt factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Bucladesine Sodium Salt, 1g, is supplied by Sigma Aldrich in a sealed amber glass vial with a detailed product label.
    Shipping Bucladesine Sodium Salt, supplied by Sigma Aldrich, Merck, or TCI, is shipped in sealed, moisture-resistant containers with cold packs or ambient temperature as recommended. All packaging complies with regulations for chemical transport to ensure product stability and safety during transit. Handling instructions and Safety Data Sheets are enclosed with each shipment.
    Storage Bucladesine Sodium Salt should be stored at 2–8°C, tightly sealed in a dry, dark location to protect it from moisture and light exposure. Avoid repeated freeze-thaw cycles. Ensure the container is properly labeled and stored away from incompatible substances. Follow manufacturer guidelines and laboratory safety protocols when handling and storing this chemical.
    Free Quote

    Competitive Bucladesine Sodium Salt prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Bucladesine Sodium Salt: Practical Insights from Our Manufacturing Floor

    Working with Bucladesine Sodium Salt every day gives us a grounded perspective on its place among cyclic AMP analogs. As a manufacturer, we have seen the laboratory requests and the research priorities shift; more scientists now want reliable options for clinically relevant second messenger mimics, and Bucladesine Sodium Salt answers that call directly. This compound, sometimes referred to by its model code NSC 66762 or as dbcAMP sodium salt, stands apart due to both its purity and performance under demanding research protocols.

    Product Introduction and Manufacturing Observations

    Our process starts with careful raw material selection. In our experience, we cannot afford shortcuts. Trace metal impurities or off-grade solvents in the supply chain disrupt cyclic AMP analog synthesis, leading to inconsistent biological outcomes. We avoid these pitfalls by maintaining rigorous upstream controls and non-negotiable quality thresholds. These choices impact every shipment and every batch, and they give confidence to the research teams who depend on the material's biological integrity.

    Bucladesine Sodium Salt comes as a highly water-soluble white or near-white powder. Chemically, it is the sodium dihydrate form of dibutyryl cyclic adenosine monophosphate. Each batch is checked for loss-on-drying, identity by HPLC and NMR, and residual solvents. Typical purity sits above 98%, not simply as a guarantee, but because applications in cell culture yield unreliable results below these levels. The melt range often confirms specification, but some clients working in high-throughput screening have asked for additional crystalline analysis—something we provide on request after reviewing their particular research application.

    Consistency in Research Applications

    The applications for Bucladesine Sodium Salt keep expanding. Researchers pick it when they want to boost intracellular cAMP without the breakdown issues that trouble conventional cAMP derivatives. In practical terms, this means less degradation by phosphodiesterases. The methyl and butyryl groups block off the main hydrolysis sites, so researchers get longer intracellular activity. Our partners in cellular signaling studies, especially those examining kinase cascades, value these properties. Whenever they compare cAMP with Bucladesine Sodium Salt in culture systems, they comment on the sharper, more sustained biological readouts.

    Not all research environments are the same. We constantly adapt our QC documentation because academic labs, biotechs, or multinationals want different technical answers. Some require detailed endotoxin levels for stem cell work; others want batch-to-batch consistency data for high-throughput pharmacological assays. From a manufacturing angle, the real challenge is locking down every variable that could throw off signaling pathway measurements. Our record-keeping must complement the demands of those precise, often single-use, experiments. Earning those repeat orders from discerning labs tells us our approach works.

    Working with Researchers: Insight into Specifications

    Lab teams often call us for guidance on dissolving, storing, and handling the sodium salt. While this compound dissolves fast in water or buffer to make neutral pH stock solutions, we routinely caution researchers about repeated freeze-thaw cycles. In repeated trials, we observed signal attenuation linked to improper aliquoting; these details, simple from our standpoint, save operators a lot of troubleshooting. We recommend dividing stock into single-use vials and storing at minus 20 Celsius. This advice comes from seeing countless projects race ahead on the strength of a stable solution and seeing others stall from overlooking these details.

    Because we supply the sodium salt form and not the free acid, labs avoid issues with variable pH adjustments. In screening campaigns and cell-based systems, that matters a great deal. Study teams skip the pre-use pH titration steps and move straight to downstream experiments, reducing time lost and minimizing batch error. Over the years, our technical support team has shared these insights in dozens of protocol consultations. Practice shows that the sodium salt delivers more predictable results, especially for cAMP-dependent kinase studies.

    Differences from Other cAMP Analogs

    Bucladesine Sodium Salt competes alongside analogs such as 8-Br-cAMP, 8-CPT-cAMP, and standard cAMP sodium salt. From our perspective, customers come to us specifically to solve the breakdown issue. Standard cAMP, for all its history, loses potency fast in enzyme-rich environments. Some analogs, like 8-Br-cAMP, improve resistance modestly but sometimes create off-target effects, especially in kinase selectivity or cell line cytotoxicity. Bucladesine Sodium Salt outperforms them in stability and cell permeability. The dibutyryl groups help cross cell membranes and resist hydrolysis; that's not just a theoretical plus but something we've noticed researchers verify by comparing EC50 values in cell growth assays.

    Every analog brings its own set of tradeoffs. We never position Bucladesine Sodium Salt as a one-size-fits-all answer. For liver and heart cell models, for instance, some experimenters find that dbcAMP’s metabolic fate affects downstream products, compared to 8-bromo analogs, where the halogen group creates different metabolic pathways. Side-by-side, hands-on uses demonstrate to us that Bucladesine Sodium Salt suits long-term signal induction or chronic stimulation studies better. Quick, highly transient responses sometimes favor conventional cAMP.

    The manuscript literature describes how Bucladesine Sodium Salt modifies gene expression, gap junction communication, or differentiation. We have distributed material to labs running everything from glial cell outgrowth to adipose tissue breakdown. The product doesn’t act as a simple switch, so we encourage users to share dose/response feedback. A researcher at a cardiovascular lab recently reported more robust PKA activation than with cAMP alone, echoing what many have found: the sodium salt maintains both entry into cells and biological stability, while other analogs drop off under comparable conditions.

    Batch Consistency and Process Transparency

    We believe scientists deserve full transparency about the source and processing of their reagents. Every order leaves our plant with batch-specific data, not just a generic certificate. That includes full chromatograms, melting point, residual water, and trace sodium content. Clients working in regulated pharmaceutical settings sometimes ask for additional ICH guideline conformity; we partner with them to customize analytical runs, so they feel confident entering in vivo projects or IND-enabling studies. This level of openness has meant we catch minor fluctuations before researchers do, and we learn from their observations as well.

    Sometimes customers ask why they can’t just use the cheapest cAMP derivative from any supplier. Any manufacturer knows that lower price sometimes comes from relaxed process controls. We’ve sampled competitor products and noticed batch-to-batch variations in appearance, solubility, or even odor. For a signaling molecule as central as Bucladesine Sodium Salt, those small inconsistencies create serious downstream risks: failed screens, ambiguous data, and costly resets in project timelines. Experience has taught us that the researchers notice—maybe not at first, but always by the time they do scale-up runs or submit pivotal papers. That’s why we keep our standards high, and our customers keep coming back.

    Meeting Specific Scientific Demands: What Sets Our Approach Apart

    The laboratories we supply stay diverse, with requests arriving from cancer biology, neurobiology, metabolism, and regenerative medicine teams. All of these demand sterile packaging and precise documentation. Some clinical labs require non-animal derived processing, and we accommodate those needs by securing our procurement pipeline and running animal-origin-free syntheses. Regulatory requests from clients help us refine our protocols—endotoxin, pyrogen, and heavy metal testing standards keep evolving, and we adapt in real time, sending detailed reports for review on an ongoing basis.

    In pilot experiments, researchers sometimes need gram-quantities for pilot animal studies. We supply custom pack sizes to avoid multiple opening-and-closing events, which can compromise product integrity. Our manufacturing insights have shaped how we advise end-users to reconstitute and aliquot their materials, as cross-contamination and moisture pick-up remain frequent pain points in high-traffic lab environments. It’s not a theoretical risk for us—it’s something we see in failed runs or contaminated plates that labs have shown us, product vials in hand. By talking directly with teams on the bench, we learn ways to engineer trouble out of the process, right down to secondary container design.

    Addressing Common Challenges in Handling Bucladesine Sodium Salt

    We spend much time troubleshooting real-world usage challenges. Solutions turn cloudy or yellow over time, typically due to unfiltered tap water, overexposure to light, or prolonged bench storage. To get the most out of every shipment, our recommendation always involves reconstitution with sterile, degassed water and storing solutions in the dark. Many researchers only think about light sensitivity with dyes, but Bucladesine Sodium Salt also breaks down faster under UV. In our experience, using amber vials and keeping tubes insulated from bench lighting ensures maximal activity. Long hours spent running controls—either in our own test labs or in discussions with customers—reinforce the connection between handling care and experiment success.

    Issues with pipetting accuracy sometimes arise in high-throughput settings. The fluffy powder can attract static and stick to the edges of weighing boats or spatulas, leading to dosing errors. We have reduced static risk by adjusting particle size in later batches, making for denser, less airborne powder. Labs pursuing automated liquid handling for screening or bioassay work have reported improved accuracy and less material loss, which helps control project budgets and schedules. Handling challenges don’t draw much attention in papers, but from the manufacturing perspective, they dictate daily lab productivity.

    Our Experiences with Customization and Continuous Feedback

    Some research consortia approach us for collaboration around variant forms of cyclic nucleotides. Over time, we have seen demand rise for selectively labeled or even isotopically enriched Bucladesine Sodium Salt. We supervise these syntheses with dedicated lines, and we adjust purification to suit NMR or mass spectrometry standards specific to these projects. Working hand-in-hand with university labs, we learn from their feedback and often tweak our own process controls. Every customized order teaches us something new, either about the properties of the material or the best practices for validation and reporting.

    Challenges often arise post-sale—delayed shipping in peak periods, customs hold-ups for certain regulatory codes, or rare but real cases of package damage. In these situations, the value of direct manufacturer-to-lab communication shows clearly. Our logistics teams scramble for replacements, and our technical support staff track the route and arrival, often following up with labs before they call us. Many large users share that this partnership speeds problem-solving, avoiding costly experiment downtime and keeping their research timelines intact.

    Why Bucladesine Sodium Salt Matters in Today’s Research Landscape

    Over years of producing cyclic nucleotide analogs, it’s plain that Bucladesine Sodium Salt continues to secure its place in signal transduction science. Its distinct structure—featuring butyrylated groups at both the N6 and O2’ positions—makes it more stable, more membrane-permeant than its parent cAMP or most rivals. This isn’t just bench chemistry; our customers’ studies confirm greater consistency in kinase assays, gene expression, and metabolic modulation, especially in cells sensitive to cyclic AMP turnover. Pharmacologists, neurobiologists, and regenerative scientists increasingly request Bucladesine Sodium Salt when they want prolonged, controlled activation of cAMP-dependent pathways.

    We have seen the rise of screening campaigns for new therapeutics boost demand. Twenty years ago, only select signal transduction labs would request analogs like this. Now, multi-well assays, organoid models, and advanced imaging platforms all line up for reliable, stable activation of second messenger cascades. From bulk shipments for high-volume screens to boutique quantities for single-use animal studies, our job never stands still. Our experience underlines an industry-wide move toward reagent traceability, custom-grade formulations, and more involved technical support. Every new application, every novel research insight, pushes us to keep refining our synthesis and distribution systems.

    Ethical Sourcing and a Transparent Manufacturing Footprint

    Responsible sourcing isn’t just a trend; it’s daily reality for us. We audit our entire supply chain—not just for chemical purity, but for human and environmental standards. Our sodium, solvents, and butyric acid all come from certified partners who adhere to fair labor and safety protocols. Documentation provided to customers reflects supply origin and traceability, giving peace of mind to institutions with strict procurement guidelines. We recycle solvent streams and minimize waste by reprocessing off-spec lots into lower-grade channels, never cutting corners on research-grade shipments. This approach meets rising expectations from universities and global biopharmas alike.

    By investing in greener synthesis methods and reducing energy consumption in purification steps, we have managed to reduce our carbon footprint per kilogram of product. External audits and process benchmarking keep us honest—sharing those details with our customers improves confidence and sets the tone for industry-wide change. These improvements aren’t finished work; each year, we review operations and look for enhancements. Our customers increasingly ask for environmental impact statements, and we meet those requests with data, not slogans.

    Partnerships with Academic and Industry Collaborators

    Knowledge doesn’t stop at the plant gate. We learn constantly from researchers using Bucladesine Sodium Salt in systems as diverse as zebrafish embryos and human adipocytes. Over the years, their results have guided us in tweaking crystallization steps, packaging choices, and even documentation standards. Some academic partners run side-by-side comparisons with competitors, and they share candid feedback on aspects like solution clarity, storage stability, or freeze-drying artifacts. Those conversations lead us to make incremental improvements that keep experiments moving forward with fewer interruptions or reruns.

    Industry partners, especially those in drug discovery and diagnostics, set the bar high for documentation and repeatability. We work closely on pilot projects, risk assessments, and supply continuity planning. Where unique regulatory filings or intellectual property considerations arise, we align our quality systems with global standards, building lasting relationships grounded in reliability and transparency. Partnerships like these hold us accountable and keep our practices tuned to the evolving frontiers of biological research and development.

    Future Outlook: Synthesis, Service, and Ongoing Learning

    Our work with Bucladesine Sodium Salt shows us that science rarely pauses. Projects grow from bench experiments to preclinical trials, and every step forward brings new challenges and fresh learning. We invest in staff education, reagent validation, and manufacturing innovation. Technical teams are always ready for protocol questions, unexpected results, or custom solution needs. Staying accessible, scientific, and flexible allows us to keep pace with fast-moving research requirements.

    Bucladesine Sodium Salt now sits at the core of so many laboratory efforts, not because it is the only solution, but because it enables controlled, reliable manipulation of a pivotal signaling pathway. Every decision we make—to upgrade a filtration cartridge, to double-check a purity curve, to overhaul a shipping partner—grows from years of noticing how even small defects ripple out across scientific results. These practical lessons help us maintain a product that is trusted in peer-reviewed journals, high-stakes pharma projects, and education settings alike.

    Wrapping up: Sharing What We’ve Learned with Every Batch

    Decades of producing and shipping Bucladesine Sodium Salt have taught us the value of close researcher-manufacturer collaboration. Every technical hiccup or product improvement reflects conversations with scientists in the trenches, running real experiments with real consequences. We welcome new requests and always seek to apply what we learn from both the expected and the surprising use cases. By sharing experience, staying accountable, and focusing on both product and partnership, we strive to elevate both the science and the practice of cyclic nucleotide research for years to come.