HS Code |
304142 |
| Productname | Biotin-PEG3-Azide |
| Casnumber | 1255942-06-9 |
| Molecularformula | C16H29N5O5S |
| Molecularweight | 419.50 g/mol |
| Purity | ≥95% (HPLC) |
| Appearance | White to off-white solid |
| Solubility | DMSO, DMF, water |
| Storagetemperature | -20°C |
| Functionalgroups | Azide, Biotin, PEG3 linker |
| Packsize | 2mg × 5 vials |
| Application | Click chemistry, bioconjugation |
| Synonyms | Azide-PEG3-Biotin |
| Smiles | C1C2C(CNC2)=C(C(=O)N1)NCCOCCOCCOCCN=[N+]=[N-] |
As an accredited Biotin-PEG3-Azide (2mg×5) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging contains five 2mg vials of Biotin-PEG3-Azide, each securely sealed, labeled for chemical grade use by Sigma Aldrich. |
| Shipping | Biotin-PEG3-Azide (2mg × 5), from Sigma Aldrich, Merck, or TCI Chemical Grade, is shipped in sealed, temperature-controlled packaging to ensure product stability. Each vial is clearly labeled, accompanied by a Certificate of Analysis, and compliant with chemical handling and safety regulations for secure delivery. |
| Storage | Biotin-PEG3-Azide (2mg × 5), supplied by Sigma-Aldrich, Merck or TCI (chemical grade), should be stored at –20°C in a tightly sealed, light-protected container. The compound must be kept dry and away from moisture to maintain stability. Allow it to reach room temperature before opening to avoid condensation. Avoid repeated freeze-thaw cycles to preserve chemical integrity. |
Competitive Biotin-PEG3-Azide (2mg×5) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
As a chemical manufacturer, real progress in bioconjugation comes from asking how people use our products at the bench every day. In the world of linking biomolecules for research, making reactions predictable and straightforward matters as much as chasing the highest raw purity. With that in mind, we develop linkers and tags for end-users in academia, diagnostics, and industry who value chemistry that always works the same way.
Biotin-PEG3-Azide is a speciality reagent we've made with both surface labeling and solution-phase conjugation in mind. Many users come to us after struggling with inconsistent lot-to-lot product or with difficulties in dissolving or recovering dry solids from other suppliers. So from our earliest production runs, our entire focus was on consistency from batch to batch, not just in appearance but also in functional group integrity and labeling performance.
Biotin continues to serve as the foundation for avidin-based affinity capture, which underpins many workflows from proteomics pulldowns to in vivo tracking. The ability to incorporate biotin efficiently, without steric clashes or diminishing site accessibility, depends on a well-designed linker. We saw multiple demands from our customers: reactions should give high conversions, products must dissolve easily in common buffer systems, and background signal or nonspecific adsorption needs to be minimal.
The PEG3 spacer in Biotin-PEG3-Azide stands as a direct answer to these needs. Too short a linker can bury the biotin, leading to poor NeutrAvidin recognition or inefficient tetramer formation. Too long a PEG chain, on the other hand, can reduce substitution efficiency or introduce solubility limits in organic solvents. From our own hands-on comparison runs, PEG3 delivers a solid middle ground—good water solubility, low aggregation, and enhanced labeling yields compared to classic straight-chain linkers.
We consistently receive direct feedback from research teams who compare our product with others in crowded markets. The most common theme runs through reliability: no batch-to-batch surprises, stable azide content for click chemistry, and a straightforward weight and handling profile. This reliability comes from process controls we've embedded over years of manufacturing linkers and biotin derivatives ourselves, not from purchasing intermediates for resale.
We decided on the 2mg×5 format based on conversations with end-users about actual lab needs. Powdered, lyophilized presentation keeps it stable for long-term storage, while dividing it into five vials at 2mg each reduces the headache of repeated freeze-thaw cycles and avoids waste. The batch documentation includes actual azide content and NMR traces so researchers can trust what goes out the door. Consistent solid form, not sticky or clumped, makes weighing and aliquoting straightforward as soon as the box arrives.
Biotin-PEG3-Azide carries our own internal batch number system for direct traceability. Across the past three years, we have refined our filtration and drying process, preserving the azido group and avoiding side-product formation. For working scientists who care about purity, the product routinely tests at above 95% by HPLC/UV with low endotoxin and residual solvent content far below thresholds that can interfere with cell-based assays or protein conjugation work.
The push in bioconjugation these days is clear: greater control over labeling, flexibility in reaction partners, and predictable yields. Investigators don't benefit from fragments or heterogeneity in their labeled material, and we've seen how even modest impurities in linker reagents undermine antibody–drug conjugate development or antibody sorting strategies. Our focus has always been on chemical integrity—maintaining the labile azide group for high-fidelity cycloaddition, while keeping the biotin accessible even after multiple reaction steps or purification cycles.
In practical use, the azido moiety in our Biotin-PEG3-Azide gives direct entry into strain-promoted or copper-catalyzed cycloaddition chemistry. We have tuned our work-up so that residual copper(II) or related heavy metals never contaminate the final product, which is a savvy design response to the growing field of copper-free click chemistry in bioorthogonal reactions. The azide signal remains sharp and easily assignable by FTIR and 1H NMR. This means direct confirmation of structural and functional integrity before and after conjugation runs, reducing troubleshooting in downstream applications.
We hear from end-users often about the need to minimize unwanted linker degradation under normal lab lighting or during aliquoting. This led us to develop protective packaging—low-static vials that prevent powder loss, cardboard shielding to limit light exposure, and recommendations for storage based on actual degradation tests. Every aspect came from listening to actual users handling these reagents—and then going back to our own labs to replicate the pain points ourselves.
There is still a knowledge gap about just how different linker lengths and architectures can change experimental results. In split-pool barcoding, proximity labeling, and high-throughput bead-based selection, small variations in linker length or flexibility translate into big differences in binding kinetics or signal-to-noise. With Biotin-PEG3-Azide, the triethylene glycol chain offers a level of flexibility and hydrophilicity that simple alkyl chains or longer PEG variants cannot match. Researchers who switch from PEG2 or PEG4 derivatives tell us the PEG3 balance consistently helps with background reduction and gives more predictable capture efficiency.
Direct use in microplate binding, magnetic bead functionalization, and protein labeling have all validated our focus. The combination of biotin accessibility and azide reactivity means that experimenters do not have to spend time optimizing basic linker chemistry; they can focus on their biological question. Extensive real-world testing underpinned our decision to state clear limitations: avoid extremes of heat and strong reducing conditions, as the azide group shows sensitivity to such environments.
Some rival suppliers emphasize ultra-long PEGs for extreme hydrophilicity or introduce proprietary spacers. Yet, end-users consistently return to PEG3 modifications for a blend of water solubility, manageable molecular weight, and performance across protein, small molecule, and nucleic acid conjugations. We routinely test Biotin-PEG3-Azide head-to-head with PEG2, PEG4, and straight-chained analogues in protein labeling of both lysine and cysteine residues. Each time, we record higher labeling efficiency on sterically hindered sites and reduced aggregation for PEG3 compared to PEG2, and better overall protein stability than PEG4.
Feedback also directs our focus to recovering biotinylated products with minimal loss. Our usage studies in antibody conjugation and surface labeling reflect common lab practices: multiple freeze-thaw cycles, various pH buffers, and repeat sonication to fully re-dissolve lyophilized solids. Biotin-PEG3-Azide consistently shows high reconstitution, whether in PBS, HEPES, or Tris-containing buffers. That's the kind of reliability that grows trust in our products—by solving real laboratory problems with each new batch.
As a manufacturer, we face the reality of variability in some industry offerings. Not all azide-modified biotin derivatives are created equal. We have acquired competitor samples and subjected them to NMR and LC-MS analysis. Several times, minor impurities, inconsistent azide loading, or the presence of less active side products have been discovered, directly impacting reaction reproducibility for scientists downstream. We address these quality gaps through in-line analytics and small-batch synthesis, so every vial matches the expectations set by prior delivered lots.
One of the most important attributes is versatility. Biotin-PEG3-Azide reacts with alkynes via click chemistry, giving scientists cross-links and tags with high selectivity, low cytotoxicity, and good reaction yields even at modest concentrations. Researchers working on cell-surface labeling, protein modification, and nucleic acid tagging find this molecule slots into hundreds of protocols without the need for extensive revalidation.
In our facilities, we test conjugation protocols using both SPAAC (strain-promoted azide-alkyne cycloaddition) and CuAAC (copper-catalyzed azide-alkyne cycloaddition) on model proteins and DNA oligos. These runs monitor not just yield, but also functional retention after biotin tagging and post-reaction biotin accessibility. Early rounds of field testing also extended to mammalian cell surface labeling, and the PEG3 spacer minimized cell stress and nonspecific background compared to shorter PEG or alkyl spacers.
End-users performing high-throughput or multi-format labeling demand both chemical stability and real-world ease of use. Protein labeling with Biotin-PEG3-Azide proceeds with clear, quantifiable shifts in molecular mass, easily followed by MALDI-TOF or ESI-MS, which is something we demonstrate in-house as part of ongoing QC. Precise azide quantification lets users calculate accurate stoichiometries for their own labeling plans.
Chemical biology is always changing. New reaction partners, fluorescent tags, and affinity assays add complexity to everyday workflows. Our drive as a manufacturer is to keep up, by refining reagents that work for the range of new protocols emerging every year. Biotin-PEG3-Azide stands as a bridge between older, robust biotinylation chemistry and new, modular approaches to cross-linking and detection.
We see product adoption expand each time a new click-compatible tool launches in the market. Laboratories who need to amplify, capture, or visualize low-abundance biomolecules often select Biotin-PEG3-Azide for its balance of feature set, managed shipping size, and reliable quality control. This flexibility empowers cross-disciplinary teams: molecular biologists, organic chemists, and bioengineers all deploy our linker in widely different settings, from benchtop screening all the way into preclinical animal studies.
Reliability has always meant more than simple lot certification. Trace contaminants and subtle lots shifts undermine research at a scale not always visible for several months. We focus our process engineering not only on final release, but on routine spot checks during synthesis and purification. Most failure points with azide linkers stem from premature reduction or dimerization, so we use low-oxygen handling and validated stabilizers to keep the azide group intact up to the moment of packaging.
Our production line integrates solvent avoidance steps to keep residuals below even the strictest guidance for advanced bioprocessing. Water-soluble byproducts are stripped away, and final filtration steps are tuned for removing iron, copper, or other trace metals. We examine every new lot for real-world performance, not just for visible contaminants or gross impurities. That vigilance emerged from collaborations with core labs who pointed out how even subtle changes in residue or salt content can derail downstream analysis.
We regularly help users troubleshoot conjugation failures, and it is often inconsistency in other supplier reactivity or solubility that emerges as the main culprit. With Biotin-PEG3-Azide, hands-on user testing drove our final production design. Vials are designed for easy opening and resealing. The powder form keeps dosing clear, without sticky residues that complicate handling. Every bottle includes a certificate with actual batch test data, not just nominal specs, and users can contact us for consultation about their application space based on direct product experience.
Bioorthogonal click labeling is a rapidly growing field, but ease of use still guides purchase decisions. Our Biotin-PEG3-Azide comes out of the vial ready for conjugation, requiring no special pretreatment or aging. Our minimal packaging also lowers the risk of static loss or powder sticking, based on direct observation in our own usage feedback loops. Researchers tell us these small, practical differences often transform a routine experiment from a source of frustration into a seamless process.
One of our principle commitments as manufacturers is staying in tune with what happens past the point of sale. Clients share both success stories and unusual failures, and we use those cases to improve shipping, packaging, or presentation. For researchers tracking low-abundance proteins using tandem mass tag workflows, a small impurity in a biotin linker can throw off results for dozens of downstream runs. Improvements stem not just from in-house testing, but from feedback and data provided by working scientists who rely on these linkers for reproducible results.
Batch uniformity, clear documentation, and technical support based on real chemist experience underpin our process. Every revision reflects user feedback, and every complaint or compliment finds its way back into process improvement discussions. The result is a product that doesn't just meet a specification but truly serves as a useful daily tool.
Biotin-PEG3-Azide does more than serve as a commodity linker; it feeds into countless research stories, from new diagnostic platforms to advanced proteomics. Our production teams know that every vial landing on a bench somewhere may move a research question forward that nobody has answered before. Exacting control over the raw materials, synthesis steps, and documentation ensures not just a single successful labeling, but the kind of reliability that can scale from pilot studies to full development programs.
Our core manufacturing team include organic chemists with decades at the bench, biologists who've run pulldown experiments themselves, and feedback from customer support calls that shape every detail of how this product appears in the hands of a researcher. Unlike intermediaries who trade on volume, we've seen firsthand how broken batches, missing azido signals, or high background ruin days or weeks of work. Our goal will always remain supporting advances in chemical biology one batch, vial, and reaction at a time.