    Specifications

    HS Code

    401124

    Chemical Name Bicine
    Iupac Name N,N-Bis(2-hydroxyethyl)glycine
    Cas Number 150-25-4
    Molecular Formula C6H13NO4
    Molar Mass 163.17 g/mol
    Physical Appearance White crystalline powder
    Pka 8.35 at 25°C
    Solubility In Water Very soluble
    Melting Point 191-194°C (decomposes)
    Buffer Range 7.6 to 9.0
    Storage Conditions Store at room temperature, in a dry place
    Synonyms Diethanolglycine
    Usage Biological buffer
    Stability Stable under recommended conditions
    Ec Number 205-746-1

    As an accredited Bicine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Bicine (Sigma-Aldrich, chemical grade) is supplied in a white plastic bottle, tightly sealed, containing 500 grams of fine white powder.
    Shipping Bicine (Sigma Aldrich/Merck/TCI Chemical Grade) is shipped in tightly sealed containers to prevent moisture absorption and contamination. The product is typically packed in robust, leak-proof bottles, accompanied by a safety data sheet. During transit, standard chemical shipping regulations are followed, including proper labeling and secure handling to ensure safe delivery.
    Storage Bicine (Sigma Aldrich/Merck/TCI Chemical Grade) should be stored in a tightly sealed container, in a cool, dry, well-ventilated area, and away from incompatible substances such as strong oxidizing agents. Protect from moisture and direct sunlight. For optimal stability, storage at room temperature (15–25°C) is recommended. Always follow the manufacturer’s storage guidelines and local regulations for chemical storage.
    Free Quote

    Competitive Bicine prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Bicine: A Practical Buffer for Biochemical Applications

    A Closer Look at Bicine’s Role in the Laboratory

    From years of producing chemical buffers and working alongside research teams in both academic labs and industrial manufacturing, I’ve seen how the need for a reliable buffering agent often defines the outcome of crucial experiments. Bicine (N,N-bis(2-hydroxyethyl)glycine) stands out in this context not for novelty, but for its predictable, consistent behavior across a wide range of life science workflows. Developed as part of the original Good’s Buffers family, Bicine’s structure and properties offer practical solutions to the type of day-to-day problems researchers face with pH control in low ionic strength environments.

    Every technician or scientist who has tried to stabilize the pH of a protein or enzyme solution knows there’s no luxury in picking an ill-suited buffer. Some agents bring ion interference. Others complicate detection methods or generate background signals. The manufacturers who handle these products shoulder a specific responsibility: purify to a grade that actually serves the work at hand, provide accurate labeling, and consistently match customer expectations batch after batch. Bicine is produced in a way that considers these real-world demands, using standardized, validated processes. We discard unnecessary impurities at every filtration stage and run small-batch analytics to flag any lot that drifts outside published pKa and purity values.

    Bicine in our catalog generally falls within the range of 99% or higher purity by HPLC, which is a necessity for most biochemistry work. Its molecular formula, C6H13NO4, incorporates two hydroxyethyl groups bonded to the glycine backbone, creating a zwitterionic molecule with an effective buffering range from pH 7.6 to 9.0. In routine applications, biologists add Bicine to enzyme assays such as creatine kinase or alkaline phosphatase where pH drift can alter kinetic readings. The buffer also stabilizes sample conditions during protein isolation, electrophoresis, or diagnostic kit formulation. We measure titration curves directly with ultraviolet absorbance and offer a certificate affirming each batch remains manganese-, zinc-, and iron-free above trace levels, following repeated requests from protein chemists who experienced unwanted metal interactions with other buffer products.

    Contrast with Traditional Buffers: Practical Differences Matter

    After over a decade of mixing and shipping both Tris and phosphate buffers alongside Bicine, product differences can’t be reduced to a choice on a website. Tris dominates the field in routine biological research for its low cost and familiar pH window near neutrality. Yet, in studies closer to alkaline conditions, Tris starts to lose its grip. Bicine preserves performance in these environments without introducing excessive ionic strength, making it better suited for enzyme systems sensitive to changes in charge density. Unlike phosphate, which can interact with metal ions or precipitate with calcium and magnesium, Bicine offers a more inert background, particularly valuable for metalloprotein research or buffering cell-free extracts that depend on trace mineral content.

    Bicine lacks the masking behavior phosphate exhibits with some dyes and analytical reagents. It shines in fluorescence-based assays, not quenching signal or producing spectral overlap. Researchers depend on this property for capillary electrophoresis and advanced immunoassays, where any contamination or optical interference directly alters published results. Simple hand tests in the QA lab have shown me that, compared to Tes or HEPES, Bicine solutions mix more easily with distilled water, reducing prep time and minimizing the chance of local precipitation in high concentration stock solutions.

    Manufacturing Bicine: Scale, Purity, and Sustainability

    Our process begins with glycine and ethylene oxide, chemicals delivered and stored under inert conditions because contamination at this stage dictates the success of every downstream step. Acid-catalyzed reactions produce the initial bis(2-hydroxyethyl)glycine skeleton, with temperature and catalyst control critical to avoid side products that complicate downstream purification. Following hydrolysis, repeated filtration and distillation cycles remove color bodies and any excess reactants. Each batch passes through charcoal treatment to strip organic residues, ensuring the final product dissolves colorlessly—an important quality for spectrophotometric work.

    As a manufacturer, longevity depends on both the consistency of production and how we handle environmental obligations. Bicine production does not require heavy metals or environmentally alarming solvents at any stage, which simplifies site waste management and aligns with current green chemistry targets set by regulatory committees. We reclaim process water, neutralize any excess base on-site, and introduce closed-loop systems that recover unreacted chemicals. This approach has kept our operational footprint below industry benchmarks for chemical waste, a point of pride among our plant managers who track effluent streams as seriously as the yields themselves.

    What Makes Bicine a Go-To for Biotechnologists?

    Every buffer offers a pKa value and a buffering window, but Bicine maintains a flat buffering capacity even at relatively dilute concentrations. Enzyme kinetics demand minimal deviation from target pH, and small shifts in buffer molarity shouldn’t collapse the system. Working as both manufacturer and consultant to some of our industrial biotechnology customers, I’ve heard from production managers running continuous fermentation systems who chose Bicine because it handles fluctuations in substrate feed or temperature without massive swings in pH.

    Some proteins require trace elements for proper folding or function. Phosphate or citrate buffers sometimes complicate matters by chelating these needed elements or forming insoluble salts. Bicine instead offers minimal interaction with most transition metals, a property confirmed by both published literature and our internal chelation studies. For companies producing recombinant proteins for the biotherapeutic market, every trace impurity in the buffer risks downstream regulatory complications. Our repeated particle analysis and metal testing, methods refined in collaboration with accredited analytical labs, show that properly made Bicine delivers the inert background demanded at this level.

    Batch Reliability and Analytical Support

    Customers ask for repeatability, and nothing frustrates a production supervisor more than discovering a buffer behaves differently from one lot to another. We monitor pH drift in long-term storage by sampling archived batches monthly over a six-month window. Our documentation tracks certificate results for color, solubility, and pH, and we routinely invite third-party auditors to review methods and lab records. This culture of open verification didn’t begin as a marketing point — it grew from seeing too many suppliers dismiss complaints as ‘user error’ rather than scrutinize their own system.

    Over the years, we’ve helped research groups transition from general-purpose buffering agents to Bicine thanks to its performance and the tight controls on manufacturing. For example, during collaborative work on diagnostic kit development, our team worked onsite with medical device engineers to confirm buffer stability over shelf-life studies. Bicine retained clarity and pH outside of extreme temperature challenge tests. We routinely supply technical bulletins that address practical concerns unique to every large order: solubility at supersaturated loads, compatibility with various preservatives, and storage recommendations to prevent caking or hygroscopic gain.

    Limitations: Where Bicine Won’t Fit

    It’s tempting to view one buffer as a catch-all solution, but that never matches reality. Bicine, for all its strengths, brings a specific buffering window. Microbiologists looking for control closer to neutrality often turn to MOPS or MES. Some molecular biologists ask about Bicine’s impact on polymerase chain reaction (PCR) efficiency. While we have seen generally neutral results in in-house tests, other buffers with more acidic or neutral pH ranges sometimes outperform it for nucleic acid amplification. The molecule’s two hydroxyethyl arms also mean Bicine can slightly increase background in certain high-sensitivity carbohydrate assays, so users handling trace sugar detection might opt for alternatives with less reactive side chains.

    Handling requirements are straightforward, but the powder absorbs water from air, so we recommend tightly sealed storage away from humid environments—or supplying solution grade drums for industrial partners who demand extra stability. This isn’t a flaw unique to Bicine; rather, it’s a reality for nearly every amino acid-based buffer we supply. Working in regions where air humidity climbs above 80%, the risk of clumping climbs as well. Our warehouse staff periodically audits packaging, switching to vacuum-packed or double-bagged containers when we ship to these climates.

    User Mistakes and Common Problems: Avoiding Pitfalls

    Lab mistakes come not from malice but from the compressed pace of research environments. Some of the most common problems with Bicine arise from rapid, imprecise pH adjustments — adding strong acid or base without proper mixing, over-shooting the desired range, or failing to calibrate meters can introduce drift undetectable in quick spot checks but disastrous during larger experiments. For these reasons, I encourage all customers to pre-dissolve Bicine in a portion of water, calibrate their pH instrument with freshly prepared standard buffers, and only adjust pH with gentle, stepwise addition of acid or base. In industrial contexts, pumps and inline sensors reduce this error, but small academic groups often benefit from extra training or written SOPs summarizing the safe handling and precise titration of buffer stocks.

    One overlooked issue concerns chemical compatibility. Bicine resists oxidation, but strong oxidizing agents or exposure to UV light over prolonged periods can eventually degrade the compound, introducing unwanted byproducts. Smaller labs occasionally store buffer stocks over months without regular turnover, which sometimes leads to discolored solution and ambiguous experimental results. Our customer service teams routinely address these queries, recommending best practices for storage temperature and container materials. We send stability data and visual inspection checklists with every major shipment—less out of regulatory need than from real experience fielding troubleshooting calls from hurried postdocs or production technicians.

    Delivering Consistency: Commitment to End Users

    Quality assurance in manufacturing looks different than just ticking boxes on a compliance sheet. Every batch comes with its own origin story: raw material scouted, reactor cleaned and cooled to meet batch size, technicians monitoring for problematic temperature spikes or sluggish filtration. Some buffers get by with minimal checks, but based on our audit results and customer feedback, Bicine demands extra diligence. Shelf-life stability hinges on tightly controlled filtration and rapid transition from drying to packaging. A missed step or a miscalculation in drying temperature has obvious consequences—powder that looks visually fine but traps hidden moisture, producing caking weeks later on the customer’s shelf.

    After sales support forms a critical part of any relationship. Most commercial buyers are not just looking for the best price or fastest shipping; they expect real technical knowledge at the other end of the phone or email. We maintain detailed records on every lot, and our technical support personnel have spent time in both the lab and the plant. This dual perspective matters when troubleshooting, whether it involves answering a detailed solubility question or helping to design a long-term stability study around a customer’s unique storage and use patterns.

    Adapting to New Demands in Buffer Technology

    The demands from life science innovation haven't stood still. Since the shift toward miniaturized diagnostic kits, biosensors, and portable lab-on-chip platforms, customers ask for buffers that not only stabilize pH but do so within small volumes and changing thermal loads. Bicine’s moderate ionic strength and low UV absorbance in the 260-280 nm range make it compatible with DNA/protein quantitation and other sensitive detection methods. Every new instrument entering the market seems to tighten requirements on background fluorescence or metal contamination. For this reason, we update manufacturing and quality methods annually based on user feedback and regulatory guidelines.

    Accessibility matters, too. Not every group operates with the luxury of large reagent budgets or advanced water purification systems. We’ve adapted packaging formats—from gram-scale bottles for teaching labs to bulk kilogram pails sealed in nitrogen for industrial lots—with an eye toward minimizing cost per experiment and simplifying workflow. Custom blending to specific pH or molarity is available, with batch certificates and detailed transparency about raw material origins and lot histories.

    Bicine in the Context of Future Scientific Needs

    Trends continue to shift toward high-throughput, automated experimentation—demands that pressure buffer manufacturers to adapt both packaging lines and quality testing. Years back, most requests revolved around high-purity powder for manual buffer prep. Today, many buyers ask for ready-diluted stocks or concentrated solutions that match precise pH values out of the box—a request driven by time savings and stricter reproducibility standards in regulated industries. We’ve invested in automated dispensing equipment and on-line UV/pH monitors, delivering Bicine ready to use for high-throughput screening, robotic workstations, or manufacturing scale assemblies with minimal manual handling.

    Longstanding customers continue to seek value from established products while asking about incremental improvements—greater solubility, lower residue, or faster dissolution rates. This dialogue helps us maintain process orientation without departing from the proven chemistry that made Bicine useful in the first place. Our plant operates with the flexibility to accommodate batch requalification and custom blend orders, recognizing the vast spectrum of end uses in medical research, industrial enzyme production, and educational settings.

    Summary of Practical Differences: Why Manufacturers and Researchers Rely on Bicine

    In competitive chemical manufacturing, reliability counts for more than advertising. Bicine delivers a buffering solution with clean dissolution, minimal UV absorption across the detection window, and limited interference in most enzymatic and protein-based applications. Where other buffers might introduce metal chelation or cloud solutions with insoluble salts, Bicine stands neutral. For every lot, we stick to narrow production tolerances, prioritizing quality documentation and ongoing analytical tests.

    End users rarely see the specifics behind raw material sourcing, reactor conditions, or process control—but they notice the aftermath if something goes wrong. By managing every aspect of the production process, from purification through long-term batch stability, we support scientific work that demands precision and consistency without adding unnecessary risk or complication. Bicine’s value emerges in each experiment that returns clean data, each kit that sits on a clinic shelf for months without change, and every researcher who finds their results unaffected by the hidden variables a suboptimal buffer too often introduces.

    With advances in molecular diagnostics, bio-manufacturing, and analytical chemistry moving faster each year, the need for buffering agents you can trust grows more urgent. Bicine remains part of the toolkit because it is more than just another reagent—it’s an answer to the everyday challenges that define work in science, manufacturing, and applied research. As both a buffer and a demonstration of our approach to responsible chemical production, it reflects a commitment to quality, transparency, and practical support for users who demand results, not excuses.