Bathophenanthrolinedisulfonic Acid

    • Product Name Bathophenanthrolinedisulfonic Acid
    • Alias BPDS
    • Einecs 259-711-2
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    503759

    Chemical Name Bathophenanthrolinedisulfonic Acid
    Synonyms 4,7-Diphenyl-1,10-phenanthroline-2,9-disulfonic acid
    Cas Number 482-85-9
    Molecular Formula C24H16N2O6S2
    Molar Mass 508.53 g/mol
    Appearance Yellow-orange powder
    Solubility Soluble in water
    Purity Varies by supplier, commonly ≥95%
    Storage Conditions Store at room temperature, protected from light and moisture
    Application Chelating agent; colorimetric reagent for iron detection
    Supplier Catalog Numbers Sigma-Aldrich: B8503, Merck: 116915, TCI: B1398
    Hazard Statements May cause skin and eye irritation

    As an accredited Bathophenanthrolinedisulfonic Acid factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Bathophenanthrolinedisulfonic Acid from Sigma Aldrich, 5 grams, packaged in a sealed amber glass bottle with detailed product labeling.
    Shipping Bathophenanthrolinedisulfonic Acid from Sigma Aldrich, Merck, or TCI Chemical is typically shipped in secure, chemical-resistant containers to ensure product stability and prevent contamination. Packaging complies with international hazardous materials regulations, providing proper labeling and documentation. Shipping is expedited and temperature-controlled if required, with tracking to ensure safe and timely delivery.
    Storage Bathophenanthrolinedisulfonic Acid should be stored in a tightly sealed container, protected from light and moisture, at room temperature (15–25°C). Store in a cool, dry place and avoid exposure to incompatible substances, such as strong oxidizers. Ensure the storage area is well-ventilated and clearly labeled. Follow the manufacturer’s safety guidelines from Sigma Aldrich, Merck, or TCI Chemical for best practices.
    Free Quote

    Competitive Bathophenanthrolinedisulfonic Acid prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Bathophenanthrolinedisulfonic Acid: Precision in Iron Detection

    Long Experience in High-Purity Fine Chemical Manufacturing

    We have spent decades synthesizing Bathophenanthrolinedisulfonic Acid (BPDSA), also recognized by its CAS number 58720-32-0 and molecular formula C18H12N2O6S2. The compound’s structure, derived from 4,7-diphenyl-1,10-phenanthroline bearing two sulfonic acid groups, puts it in a niche group of phenanthroline derivatives that offer distinct chemical features and application advantages. In our hands, the manufacturing process prioritizes rigorous impurity removal because trace contaminants can have a strong influence on its analytical performance.

    Years of feedback from chemists and medical technicians have reinforced our focus on purity: minor variations in BPDSA’s production impact its iron-sensing capabilities, particularly in colorimetric assays where reliable calibration matters. Our batches maintain strict specifications for sulfonation degree, moisture content, and residual metals. Analytical grade BPDSA from our facilities presents as a yellow to yellow-orange powder, typically supplied in sealed amber glass to guard against photodegradation and atmospheric moisture pickup.

    Understanding Its Role in Analytical Chemistry

    The strength of Bathophenanthrolinedisulfonic Acid lies in its ability to form highly stable complexes with Fe2+ ions. Upon reduction of iron(III) to iron(II) in a sample, BPDSA reacts to produce a deep red complex, facilitating photometric iron quantification with strong molar absorptivity. This color development forms the backbone of many clinical labs’ iron assays and a wide range of biochemical research tools. Analytical chemists trust BPDSA-based assays to deliver accuracy at low iron concentrations, whether analyzing drinking water, biological tissue, or pharmaceutical products.

    The key reason to choose Bathophenanthrolinedisulfonic Acid rather than other iron indicators—such as ferrozine or o-phenanthroline—often comes down to its water solubility. The disulfonic acid groups dramatically enhance solubility, so complexation reactions run efficiently in purely aqueous environments, bypassing the need for miscible organic solvents. This plays a vital part in clinical workflows and reduces chemical hazards associated with organic reagents.

    Preparation of working solutions usually only requires deionized water, and the final colorimetric readings remain highly reproducible because BPDSA’s structure prevents precipitation and secondary interactions with most sample matrices. Customers involved in high-throughput diagnostics report that reagent stability minimizes downtime and repeat sampling, helping deliver consistent results throughout large batches.

    Comparing BPDSA With Similar Ligands

    Chemists have compared Bathophenanthrolinedisulfonic Acid with traditional 1,10-phenanthroline and its mono-sulfonated counterparts. Standard phenanthroline ligands lack the strong water solubility of BPDSA, often leading to slower complexation or less consistent color formation when samples involve buffers or potential precipitating agents. Mono-sulfonated forms provide some solubility improvements, but we have observed that further sulfonation—specifically, introducing two sulfonic groups—offers both stronger complex formation and greater resistance to interfering compounds, such as phosphate or EDTA.

    BPDSA’s performance stands out when the target application involves complex biological samples or environmental matrices. Here, side reactions with proteins, amino acids, or trace organics can strongly bias readings with phenanthroline or ferrozine indicators. Our partners in clinical diagnostics observe that BPDSA reduces such matrix effects, translating into sharper peaks and better linearity in spectrometric measurement. Those setting up protocols for serum, plasma, or food testing often rely on BPDSA for this reason, eliminating repeated troubleshooting that plagues laboratories working with more basic indicators.

    Production Control and Analytical Validation

    Manufacturing BPDSA involves multi-step synthesis from carefully selected starting materials. We manage every stage in-house, including initial condensation of phenanthroline, selective sulfonation, and rigorous purification. Final product quality hinges on removing residual acids, inorganic salts, and by-products—impurities that even in the low ppm range can shift the colorimetric response curve. Our monitoring protocols involve UV-Vis, NMR, and endpoint titration to validate batch-to-batch consistency; we tighten release criteria when feedback suggests even marginal out-of-spec readings in customer labs.

    Our users depend on transparency in quality control, so we publish full certs of analysis for each batch, detailing methods and observed spectral properties. Many in the pharmaceutical or food industries require impurity profiles to comply with regulatory submissions, which guides us to invest in better analytical infrastructure. We also operate pilot lines to trial process enhancements before shifting any new manufacturing approach to full production: this reduces risk and offers laboratory clients a direct feedback loop for performance changes.

    Commercial Impact and Evolving Application Demands

    BPDSA’s main use—quantitative iron analysis—keeps it central to the work of clinical chemists and environmental monitors. Over the past decade, detection limits have tightened as regulators push for higher sensitivity; most labs now monitor iron in water at sub-ppb levels, and even clinical diagnostics scrutinize iron in trace amounts because of its major impact on disease diagnosis. We remain directly engaged with laboratories setting up such assays, tuning BPDSA purity and packaging to meet the new demands for both sensitivity and robustness.

    Automation of clinical and water analysis workflows has also changed attitudes toward indicator chemistry. With robots handling test plates and microfluidics moving sample volumes down to the single-digit microliter scale, stability and reactivity of colorimetric reagents such as BPDSA become mission-critical. We run accelerated aging studies in parallel with traditional shelf-life trials, identifying early which impurities or stabilizer tweaks prolong reagent life under these use-case stresses.

    Case Study: BPDSA in Hospital Laboratory Use

    One mid-sized hospital faced increasing test failures in serum iron assays, particularly involving turbid or colored patient samples. Having used ferrozine for years, the lab team noticed frequent interference from hemolysis and sample matrix proteins, leading to ambiguous results that needed manual reinterpretation. After evaluating multiple alternatives, they migrated their protocols to our BPDSA reagent, drawn in by both published literature and our technical support. Within three weeks, they reported a 40% drop in ambiguous readings, and the test turnaround improved with staff spending less time adjusting for background absorbance. These improvements led the hospital’s central purchasing to standardize on BPDSA for iron testing, freeing up technicians for higher-complexity cases instead of routine troubleshooting. This practical field evidence keeps us focused on real-world robustness, not just theoretical assay performance.

    Researcher Needs and Scalability in Synthesis

    Academic groups developing new iron sensors or probing trace metal binding find BPDSA’s reproducibility critical. We supply small lots to university chemistry departments that experiment with improved iron chelation techniques for medical diagnostics and environmental sampling. Their experimental feedback—such as requests for modified counterions or tailored particle sizes—feeds back to our process engineers, who then assess the impact of these changes on product stability.

    Recently, researchers investigating non-invasive iron status in living organisms have adopted BPDSA complexes for fluorescent and chemiluminescent probe development. Since these uses demand highly predictable photophysical characteristics, our control over batch-to-batch consistency offers the confidence researchers need; a single out-of-spec sample can ruin an entire study, setting back projects for months. Scientists have credited BPDSA’s purity with smoother assay calibration and more reliable statistical outputs.

    Minimizing Environmental Impact and Safe Handling

    Sulfonated aromatic compounds require particular attention during disposal to prevent environmental accumulation. We continually refine our manufacturing and packaging protocols to minimize residual organics in waste streams. Our staff receive regular training on waste handling, and we encourage our customers to use the smallest feasible reagent amounts, reconstitute only what is needed, and follow institutional procedures for hazardous waste disposal. Over the past five years, we reduced per-batch solvent usage by nearly 20% by shifting to continuous reaction monitoring, and we are piloting alternative sulfonation methods that cut down acid consumption.

    Lab technicians and production staff deserve reliability and safety, so we install containment measures to avoid inhalation and accidental contact. In line with safety principles, we supply BPDSA in air-tight, light-protective bottles clearly coded to prevent misapplication. Our tech support team takes user feedback seriously; for example, following a pattern of early clumping issues in high-humidity regions, we trialed and switched to improved packaging with upgraded desiccant sachets, reducing product caking and improving dispense accuracy.

    Global Standards and Shipping Considerations

    Scientific teams worldwide rely on strict documentation and compliance. Because different markets—Europe, North America, Asia—impose varying import and regulatory requirements, we synchronize our batch testing, labeling, and packaging to satisfy the broadest set of global demands. Laboratories value being able to trace material origin and batch trajectory, especially as more research gets published using our BPDSA.

    Shipping high-purity BPDSA across long distances introduces real risk of atmospheric moisture uptake and thermal exposure. To reduce such risks, our logistics chain incorporates multi-layered vacuum sealing and temperature logging during transit. Repeat laboratory clients often set up scheduled deliveries, keeping their supplies predictable and avoiding last-minute ordering that could compromise scientific workflow.

    Supporting Next-Generation Iron Diagnostics

    Emerging health technologies keep challenging analytical reagents to deliver better selectivity and speed. Many diagnostic device startups now request BPDSA formulations compatible with miniaturized, user-operated spectrometers or chip-based assay formats. In response, we work with their teams on solution stability, alternative salt forms, and powdered single-dose sachets to fit device protocols while controlling for shelf-life and sensitivity. As healthcare migrates toward decentralized models, trusted performance in small, flexible analytical platforms matters more than ever.

    Over time, BPDSA has moved from an academic specialty material to a linchpin of analytical workflows in quality control and health science. Competing ligands have strengths but usually trade off solubility, speed, or freedom from interference; our clients tell us they stay with BPDSA because it keeps protocols running and lets them move quickly from sample prep to result validation.

    Insights From Firsthand Experience

    Manufacturing high-purity Bathophenanthrolinedisulfonic Acid requires discipline at every step. Small slips in temperature or pH can introduce side reactions and create invisible impurities. Our teams learned from trial and error: in early years, small changes in inlet water purity or solvent grade led to spectral drift that would have gone unnoticed without feedback from end-users. Today, every operator on the line gets hands-on training in not only the chemistry, but also the downstream applications—the core reason why 99.5% purity matters isn’t academic, but practical. Analytical runs often unravel over small process variables overlooked in production, so we invest in continuous improvement, employee certification, and feedback loops that reach from the factory floor up to senior management and down again.

    Strong ties with analytical chemists, instrument companies, and academic researchers inform our priorities each year. It’s one thing to manufacture to a fixed spec; it’s another to hear directly how a fraction of a percent additional purity improves detection in newborn screenings or iron-deficiency diagnostics. These stories push us to constantly review and update our purification and QC methods.

    Summary: Value in Consistent Performance and Expert Support

    Bathophenanthrolinedisulfonic Acid brings proven advantages for anyone needing high-sensitivity, low-interference iron assays. Real-world conditions rarely match perfect laboratory test cases, so the reliable behavior of BPDSA under variation matters to thousands of professionals worldwide. Our day-to-day experience as actual producers, not intermediaries or resellers, means we see both the upstream production details and the downstream impact on users’ results.

    With strict process control, world-class quality analytics, and a strong channel for customer feedback, we ensure BPDSA continues to serve as a robust, versatile tool as scientific and clinical demands evolve. Its distinction—from traditional phenanthroline compounds and other iron indicators—comes from not only its unique water solubility and selectivity, but also from layered improvements born of experience, feedback, and ongoing investment in both manufacturing and analytical advancement.

    Our story merges chemistry with application, measuring success not by how many kilograms we ship but by the trust placed in the material by those who use it to answer meaningful questions in science, medicine, and industry. Bathophenanthrolinedisulfonic Acid endures as a testament to the importance of hands-on expertise and a genuine partnership between producers and practitioners.