HS Code |
533799 |
| Product Name | Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated) |
| Conjugate | Peroxidase (HRP) |
| Host Species | Goat |
| Specificity | Fc region of Human IgG |
| Form | Liquid |
| Preservative | 0.02% Thimerosal |
| Purification | Affinity purified |
| Applications | ELISA, Western Blot, Immunohistochemistry |
| Clone | Polyclonal |
| Supplier | Sigma-Aldrich |
| Catalog Number | A0170 |
| Storage Temperature | 2-8°C |
| Immunogen | Human IgG Fc fragment |
| Buffer | Phosphate Buffered Saline (PBS), pH 7.2 |
| Species Reactivity | Human |
| Isotype | Goat IgG |
| Dilution Range | 1:2,000–1:10,000 (ELISA/WB, typical) |
| Lot Number | Varies by batch |
| Expiration | Refer to COA or product label |
| Shipping Conditions | Ice pack |
As an accredited Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging is a 1 mL amber glass vial with a white screw cap, labeled "Anti-Human IgG (Fc), Peroxidase-Conjugated, Sigma-Aldrich." |
| Shipping | The **Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated)** from Sigma Aldrich/Merck/TCI Chemical is shipped in specialized packaging with ice packs or dry ice to maintain stability. The product is handled as a temperature-sensitive reagent and shipped via express delivery to ensure prompt arrival and product integrity upon receipt. |
| Storage | Store **Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated) from Sigma-Aldrich/Merck/TCI Chemical** at 2–8°C in a tightly closed, light-protected container. Do not freeze. Avoid repeated freeze-thaw cycles to maintain reagent stability. Handle using aseptic techniques to prevent contamination. Protect from direct sunlight and corrosive chemicals to preserve peroxidase activity and antibody integrity for optimal performance in assays. |
Competitive Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Making antibodies for research is not a job you can rush or take lightly. Quality and trust ride on every lot and every batch. For years in our work developing immunoreagents, one request comes up again and again: consistent detection without unwanted noise from cross-reactivity. Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated) tackles this directly. Our team produces each batch in-house, using human IgG as an immunogen and affinity purification steps that ensure a high degree of Fc specificity. This process trims down off-target binding, even in complex biological samples or high-throughput settings.
Whether you’re looking for signals in a patient’s plasma or running ELISAs that depend on reliable signal-to-noise ratios, this antibody brings forward reliable results. We’ve watched researchers struggle with background issues stemming from antibodies that latch onto Fab fragments or other immunoglobulin domains. By focusing on the Fc region, this product sticks to the real target, ignoring light-chains, fragments, or similar immunoglobulins floating in the mixture. Fc specificity stands as the most important requirement where subclass or isotype switching complicates detection.
Enzyme conjugation is more than “just” labeling. Through years of hands-on experimentation, we’ve confirmed that direct conjugation of horseradish peroxidase (HRP) to the purified antibody provides high-powered signal amplification with minimal background. Stray labeling causes weak signal or loss of target binding, so procedures matter. Batch-to-batch reproducibility, as shown in our internal controls, opens the door to reliable protocol development in the lab. We avoid excess or non-specific labeling, which preserves Fc recognition and shortens troubleshooting time for scientists working in busy labs.
Peroxidase-based detection fits a wide array of colorimetric and chemiluminescent readout platforms. Over the last decade, this flexibility has expanded use far outside traditional immunoassays. People use this antibody for western blotting, immunohistochemistry, ELISA, and even new diagnostic methods that require robust enzymatic responses. Even with new detection substrates coming into play, HRP remains trusted for its stability and signal consistency, especially when integrated with a carefully purified IgG backbone.
Having worked directly on production lines and alongside quality control teams, I’ve seen the practical difference that specificity makes. Traditional anti-IgG antibodies are easier to generate, but often bind to everything from IgM, IgA to various subclasses. In cross-reactivity assays, non-specific binding shows up as stray bands and false positives. Those who run immunoprecipitation on complex lysates or seek to distinguish between primary and secondary antibody origin notice this right away. Our Fc-specific antibody keeps detection clean, especially when you use mouse antibodies in the same experiment or check for human IgG without picking up fragments or complexes.
Diving into the molecular biology of antibodies, the Fc region points to the constant segment of the heavy chain. By binding there, detection focuses purely on intact IgG molecules. This specificity matters if you're testing for total IgG or looking for immune responses in vaccinated subjects. For direct detection or when layering antibodies from different species, cross-reactivity can introduce error and cast doubt on data interpretation. We've seen researchers resort to complicated controls or rounds of antibody titration, all for the sake of avoiding background. Using an Fc-specific secondary reduces the need for such workarounds.
Day by day, real research hinges on the small details in reagent handling. Some teams use our Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated) directly in diagnostic setups, where sample volume, cost per test, and reproducibility take center stage. Others stretch it across screening plates with hundreds of wells, demanding action in conditions as varied as urine, saliva, or cell culture supernatants. Purity and titer matter most when the timeline gets tight. A stable antibody that resists denaturation and gives strong signals at low concentrations costs less and wastes less time. We manufacture and QC this antibody to ensure both stability and high working dilution—minimum fuss for maximum performance.
Not every secondary antibody is built for such range. With years of scaling up batches and fine-tuning purification, we’ve learned that up-front investment in specificity pays back in reduced troubleshooting downstream. Troubles brought on by secondary antibodies that cross-react or degrade under storage can upend large studies and waste weeks of work. Storage and temperature fluctuations in mail or during long bench days challenge antibody structure and function; we push for formulations with effective stabilizers so that research teams don’t run into surprise failures.
Many research partners focus on diagnostics and patient sample processing, where errors in detection cascade into misinterpretation. For example, clinical immunology labs screening for autoimmune responses or monitoring therapeutic antibodies in patient serum can’t afford ambiguity. Fc-specific detection ensures low background and mitigates the risk of misreading Fab fragments or degraded immunoglobulins as positive signals. In some collaborative projects, we’ve seen projects gain regulatory clearance faster because they sidestep cross-species reactivity and stick to validated pathways.
Pharma and clinical trial sponsors want robust reagents that pass validation with regulatory bodies. The same goes for diagnostic developers juggling multiplexed immunoassays. Product recalls and failed batches cost far more than up-front attention to antibody origin and purification. With Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated), quality audits check out due to traceable documentation for every step, and our track record with CAP/CLIA and ISO-certified labs stands as a reference.
We supply this product under the code AHPH-302, representing our Fc-specific series targeting human immunoglobulin G. In the journey from milligram-scale pilot batches to kilogram-scale regular runs, we found the sweet spot in terms of working concentration sits between 1:2,000 to 1:20,000 in standard ELISA and western blotting workflows. Substrate compatibility covers standard TMB, OPD, and chemiluminescent reagents, so scientists won’t find themselves stuck with a one-use reagent.
End-point testing includes both class-specificity panels and stress tests for enzymatic activity after temperature cycling. In real terms, users can freeze and thaw the reagent repeatedly without losing detection power, which supports extended storage and frequent use in core laboratories. The carrier-free format means no interfering preservatives, which can affect chromogenic substrates or cell-based applications. Lyophilized forms also fit into global shipping needs, keeping antibodies stable without refrigeration for moderate periods.
A question we face often: how does this differ from a typical anti-IgG peroxidase conjugate? The answer rests on two main factors: specificity and background cleaning. Standard anti-human IgG antibodies tend to grab multiple immunoglobulin fragments, including light chains, Fab, and sometimes even other classes. For basic applications where rough estimation of immunoglobulin is enough, those may suffice. But in layered assays—split signal formats, sandwich ELISAs, or complex sample matrices—those products cost accuracy and consistency.
In our discussions with immunologists and diagnostic developers, the recurring issue is misinterpretation of bands or dots. Conventional conjugates might light up both the control and test samples, make weak positives look overstated, or miss subtle shifts between subclasses. Fc-specificity means only intact human IgG counts—no extra signals from degraded antibodies or immune complexes. This becomes crucial where data integrity isn’t optional. On practical grounds, our colleagues in the diagnostic industry have flagged far fewer “gray zone” results after switching to Fc-specific platforms.
Walking the floor in our facilities, we monitor each manufacturing and purification cycle closely. Each affinity column gets checked before and after runs; the downstream QA team pulls samples early, mid, and late-batch for cross-reactivity screens. We learned the hard way that incomplete separation breeds signal creep. Documentation goes hand in hand with physical checks; operators use a rigorous step-by-step process to compare every lot against historical controls before release. Large-scale customers have confidence knowing batch records and continuous improvement efforts stand behind every vial.
Batch-to-batch and long-term stability are constant themes in our feedback loop with end users. Teams building test kits to sell worldwide submit reagents to regulatory authorities for repeat evaluation, so consistency matters. From pilot-scale runs to high-volume production, we standardize all raw material inputs and validate each production step against ISO-mandated criteria. Rapidly detecting and solving bottlenecks is only possible with direct manufacturer access; we work hand-in-hand with our customers to tweak formulations or labeling density when performance standards shift.
Every few years, new research pushes the limits of assay sensitivity, throughput, or sample diversity. Groups working on next-generation diagnostics or population serology rely on sturdy antibody reagents that hold up after years of storage or thousands of cycles. Customer feedback drives improvement. Multiple research consortia update us on their needs for higher signal-to-noise ratios, or for antibody kits that stand up to rapid changes in workflow.
We invest in ongoing cross-comparison studies with alternate products, checking for drift in background signal, enzyme activity, and detectability across sample cohorts from varied ethnic and age groups. Open collaboration means we can flag performance changes early and roll out fixes before they trip up major studies. This hands-on approach, from manufacturing through to post-market support, is what lets us provide well-documented, high-performing immunoreagents.
Over the past decade, the number of uses for Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated) has grown far beyond the classic western blot or ELISA. Research teams interested in emerging screening platforms—such as high-density protein arrays or single-cell multiplexing—need reagents with strict specificity and high compatibility with automated platforms. We work alongside automation and instrument designers to confirm that peroxidase-conjugated Fc-specific antibodies integrate into existing pipelines smoothly, with readout clarity and no drift.
Some users apply this antibody to support clinical trial biomarker studies where baseline and post-treatment differences are subtle. Others rely on it for quality control in bioproduction facilities, as part of host cell protein testing or confirmation of therapeutic antibody integrity. The bottom line is, as the technology for protein detection evolves, so must the calibrations and refinements we make along the way—always with feedback and evidence driving the next version.
Manufacturing high-performance immunoreagents isn’t just about skilled technicians or top equipment. It’s about understanding what the bench researcher or development scientist faces every day—tight timelines, cost limits, and the absolute need to trust data. Years refining antibody purification, enzyme conjugation, and QA checkpoints have taught us that shortcuts early only come back as troubleshooting headaches for the end user.
Our direct involvement in every batch lets us field questions from customers with real answers, not speculation. If a scientist says a signal came up too high or didn’t appear in a specific matrix, we can go back through production records, run new analytical checks, and, if needed, adapt the process for future lots. The direct manufacturer relationship means we hear about problems first and can test potential solutions with our own hands, on our own equipment.
Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated) grew out of common research needs for precise, reproducible antibody detection. By controlling every aspect of development and manufacturing, we deliver a product that addresses concerns about background signal, substrate compatibility, and batch-to-batch performance. Continuous feedback and direct problem-solving keep us close to the changing realities of research, diagnostics, and clinical testing.
Stable supply, rigorous validation, and real-world partnerships define our commitment. Choosing an antibody direct from the source brings the knowledge, experience, and accountability that complex biological research now demands. Whether confirming data in a diagnostic lab or charting new directions in immunoprotein detection, Anti-Human IgG (Fc-Specific, Peroxidase-Conjugated) stands as a tested solution from a team that knows the stakes firsthand and stands by the science every step of the way.