West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

AEE 788

    • Product Name AEE 788
    • Alias PLATINUM
    • Einecs 685273-00-1
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    533517

    Name AEE 788
    Type small molecule inhibitor
    Molecular Formula C28H27F3N4O3
    Mechanism Of Action dual inhibitor of EGFR and VEGFR tyrosine kinases
    Molecular Weight 524.54 g/mol
    Chemical Class quinazoline derivative
    Administration Route oral
    Primary Indication anticancer therapeutic
    Development Stage investigational
    Cas Number 497839-62-0
    Target Proteins EGFR, VEGFR
    Solubility low aqueous solubility
    Bioavailability limited oral bioavailability
    Synonyms NVP-AEE788
    Developer Novartis

    As an accredited AEE 788 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing AEE 788 from Sigma Aldrich is supplied in a sealed amber glass vial containing 25 mg, labeled with product details and safety information.
    Shipping AEE 788 ships in secure, chemically-resistant packaging to ensure safe handling and transport. The product is dispatched at ambient temperature unless otherwise specified for stability, and includes standard documentation (COA, SDS). Shipping complies with international regulations for chemical substances and may require recipient confirmation of authorized chemical use.
    Storage AEE 788 should be stored in a tightly sealed container, protected from light and moisture. Store at -20°C in a dry, well-ventilated area, away from incompatible substances. Handle under an inert atmosphere if possible to prevent degradation. Ensure proper labeling and avoid repeated freeze-thaw cycles to maintain chemical stability and integrity. Follow material safety data sheet (MSDS) guidelines for handling and storage.
    Free Quote

    Competitive AEE 788 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    AEE 788: Delivering Reproducibility and Confidence in Advanced Chemical Synthesis

    Designed for Precision in Every Batch

    Our experience manufacturing AEE 788 over the years has taught us a few things about both the technical details and the practical realities of research and commercial-scale chemistry. AEE 788, known by its CAS number 497839-62-0, serves as a multipurpose small-molecule tyrosine kinase inhibitor with strong selectivity for both EGFR and VEGFR phosphorylation sites. Its formula stands out: C24H22N4O2, designed with a molecular weight of 398.46 g/mol to meet the reliability standards that researchers and process engineers demand. Complex manufacturing routes for inhibitors like AEE 788 require attentive quality management, and this is one of the products where tight control of all synthesis and purification steps pays real dividends in the lab and downstream processing.

    Built by Hands-on Expertise

    There are no shortcuts in producing AEE 788 at a purity that meets the expectations of lead discovery teams. Only relentless process optimization delivers batch-to-batch consistency. Our technical teams insist on confirming spectral signatures against authentic references at every run. HPLC analysis pushes the minimum purity of every lot to 99%. We won’t settle for ambiguity in the presence of closely related process-related impurities, since tolerances here make all the difference in preclinical screens or biomarker discovery. Over decades, we have refined handling protocols at every step in our dry room space and analytical lab to keep oxygen and moisture exposure below the critical threshold that can threaten sensitive molecules like AEE 788—especially as you scale from grams to kilograms.

    We built our lines to directly accommodate this molecule's solubility characteristics and stability needs. AEE 788 benefits from development on dedicated glass reactors lined to minimize extractables and cross-contamination. The bottling/packaging work also relies on deep material compatibility studies. We learned from early packaging setbacks years ago: you don’t want to risk compromised stability from a poor seal or residual solvent traces. We use thick-walled amber glass containers, flushed with high-purity nitrogen and heat-sealed with precision before release. That focus pays off in preserving AEE 788’s properties from the first sampling to vial delivery on-site.

    Defining Features in Action

    Real-world application drives our design decisions at every stage. We see AEE 788 drive new approaches in receptor-targeted oncology studies, signaling pathway research, and kinase activity profiling. In drug discovery campaigns, its high inhibitor selectivity often means fewer off-target effects during cell-based assays, providing cleaner readouts compared to broader-spectrum tyrosine kinase inhibitors. Where research projects demand highly defined signaling pathway modulation, AEE 788 has proven itself at both the exploratory and process validation stages.

    In one collaboration, a biotech partner challenged us to support an annual kilo-scale campaign of AEE 788 with no interruptions and no drift in key impurity thresholds. Our solution combined in-line NMR to monitor critical intermediates, a double stage recrystallization, and filtered bottle transfers under positive pressure. These process adjustments ensured every delivery exceeded customer specifications, allowing for robust bioassay data and improved downstream formulation reliability.

    AEE 788 vs. Other Small Molecule Inhibitors

    The landscape for kinase inhibitors continues to evolve, but raw synthesis and process quality make tangible differences. Generic kinases often handle variable tolerances for side-products, which undermines reliable analytics or clinical translation. AEE 788, by design and in practice, stands apart through higher purity and low levels of isomeric or oxidative contaminants. Many alternate EGFR/VEGFR inhibitors require stabilization with excipients during formulation, masking batch-to-batch instabilities; our batches show clean, stable melting points and sharp spectral signatures right off the line.

    Customers often compare AEE 788 with alternatives like erlotinib hydrochloride or vandetanib in multi-pathway studies. Unlike those products packaged in bulk by resellers with little process oversight, our batches come with full traceability, independent lab verification, and retained samples for retrospective testing. We learned early that research teams burn time and money chasing inconsistent data from variable product sources. Investing in proper process isolation and analytical review isn’t overhead—it’s preventative medicine for both our own brand and customer outcomes.

    Putting Trust into Every Batch Release

    We take feedback seriously from research chemists and manufacturing engineers who “walk the line” with AEE 788, both in the basic sciences and as production scales up for clinical use. At larger scale, we’ve improved handling systems for dust and fine particle control to minimize respiratory exposure on-site. Automated powder funnels and HEPA-filtered hood systems cut down operator fatigue—important when transferring high-purity cytostatic agents. Our documentation protocols extend to capturing every environmental parameter at the moment of sampling, which protects integrity when the material travels far.

    Over time, we adopted electronic batch records and digital chain-of-custody systems so every check and calibration, every deviation, and every final measurement links directly to the final product’s identity. This goes far beyond any compliance tick-box. Having full transparency actually reduces time in process reviews and technical troubleshooting, eliminating guesswork for partners who rely on our product. We keep reference lots archived and accessible for at least five years, supporting retrospective consistency checks for regulatory filings or litigation support.

    Supporting Evolving Research Needs

    Developing and manufacturing AEE 788 has taught us how quickly research priorities can shift. Some groups focus on tool compound validation or exploring novel EGFR/VEGFR resistance mechanisms; others drive programs toward regulatory-compliant API grades. The best way to support all these efforts is to operate as a partner rather than just a supplier. When collaborators need ultra-fine particle grades for high-throughput screening or larger lots for scale-up, our teams work with them to adjust particle size reduction or solvent rinse steps without compromising on impurity levels.

    We do not offer a one-size-fits-all approach. Clients may request special packaging, additional drying cycles, or tailored delivery schedules to match their specific timelines or storage capabilities. Every modification is risk-assessed against our original process qualification, with proper change control and revalidation—an approach built from our hands-on experience dealing with high-value, sensitive molecules. Our technical team participates directly in project planning meetings when requested, providing support that goes beyond routine batch supply.

    Driving Innovation through Collaboration

    AEE 788’s path through our process development pipeline came with challenges—unusual impurities after long reaction holds and unpredictable polymorphism under different crystallization temperatures. We solved these using orthogonal analytical tools, including two-dimensional NMR and high-resolution mass spectrometry, catching trace levels of latent side-products that otherwise compromise downstream formulations. Each improvement strengthened our own manufacturing discipline as well as product performance at research sites.

    Many researchers trust our manufacturing process because we show the data, not just the certificate. Before releasing any lot of AEE 788, we run inter-lab studies with outside partners to cross-check chromatographic and NMR fingerprints. This active data-sharing fosters confidence and accountability beyond lab reports.

    For downstream projects—especially those that transition from bench-top screening to pilot plant—our project engineers join technical reviews on solvent transfer, closed-system modifications, and even downstream formulation development. Every scale brings a new set of risks and opportunities. By handling these in real time with our partners, both sides help avoid bottlenecks late in development, keeping projects on track.

    Environmental and Employee Safety Considerations

    Careful process planning helps minimize both waste and exposure risks. We use real-time temperature and pH monitoring to precisely hit critical endpoints and to reduce byproduct formation. Our waste streams move through activated carbon and advanced solvent recovery units, trimming both environmental load and production cost. Colleagues working with AEE 788 receive specialized training not just in handling hazardous materials, but also in sample tracking and cross-contamination prevention—critical skills for scientists who want to deliver not only safe workspaces, but also reproducible science.

    We conduct quarterly hazard mapping and process hazard analyses (PHA) for the AEE 788 suites, inviting feedback directly from operators, analysts, and maintenance staff. Key process safeguards are continually revised based on first-hand experience with batch and test room near-misses. Company ownership at every level drives sustained safety improvements instead of a “set it and forget it” model.

    Shaping the Future of Chemical Manufacturing

    Every day, our team improves the process of synthesizing and isolating cutting-edge molecules like AEE 788. Unlike external traders or brokers, we focus on product lifecycles, not inventory cycles. We invest in ongoing equipment upgrades, risk assessment, and scientific skills development, because this shift translates into higher yield, lower upsets, and faster troubleshooting support for our downstream users.

    Several times a year, project teams in our pilot plant roll out process innovations—better filtration, deeper impurity profiling, inline solvent switching—that directly benefit customers using AEE 788 at any stage of their work. We understand from hands-on experience that it’s not just about hitting quality numbers, it’s about ensuring every vial represents actionable data for the teams that depend on it. Our own ongoing research in process chemistry and analytical science keeps the bar moving forward, both for this molecule and for new generations of similar kinase inhibitors.

    Staying close to our partners has also helped us adapt to changes in regulatory landscapes and industry standard requirements. Whether a client operates a local discovery lab or navigates international regulatory filings, we work side by side to ensure AEE 788 delivered from our site tracks every critical parameter—identity, purity, residual solvent level, and physical characteristics. We meet both standard and customized reporting requirements, drawing on years of experience preparing documentation for preclinical and clinical development.

    Customer-Centered Solutions for Varied Project Needs

    Each research project that leaps forward on the strength of reliable chemical supply validates our core approach. We understand that teams may need tailored product solutions—whether it’s high-purity analytical reference standards, bulk process lots, or distinct particle grades. We engage early to help researchers define the right specifications, and we refine our process to support innovations both large and small.

    We accommodate varied storage setups, facilitate rapid dispatch for urgent requests, and manage temperature or humidity control during transit based on careful discussions with each customer site. Our job does not stop at the gate—technical support, process optimization suggestions, or repeat-run feedback integrate back into our continuous improvement loop. Open communication drives collective success for everyone working with AEE 788.

    Conclusion: A Legacy of Dedication

    Producing and supplying AEE 788 is about much more than following protocols. Our hands-on approach reflects decades spent in synthesis labs, pilot plants, and quality suites. Every improvement, every safeguard, and every technical adjustment speaks to lessons learned through direct manufacturing experience. Choosing a manufacturer for critical research chemicals like AEE 788 demands more than catalog shopping. We welcome every opportunity to help research, development, and commercial teams move their science forward—delivering each lot with the same pride as our very first batch.