HS Code |
950617 |
| Product Name | Acetone-d6 |
| Synonyms | Hexadeuteroacetone |
| Chemical Formula | C3D6O |
| Molecular Weight | 64.12 g/mol |
| Cas Number | 666-52-4 |
| Appearance | Clear colorless liquid |
| Purity | Typically ≥99.9% atom D |
| Boiling Point | 55-57°C |
| Melting Point | -94.7°C |
| Density | 0.873 g/mL at 25°C |
| Refractive Index | n20/D 1.355 |
| Storage Temperature | Room temperature |
| Solubility | Miscible with water and most organic solvents |
As an accredited Acetone-d6 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Acetone-d6 is supplied by Sigma Aldrich in a 100 mL amber glass bottle, tightly sealed, with clear hazard and purity labeling. |
| Shipping | Acetone-d6 from Sigma Aldrich, Merck, or TCI Chemical is shipped in tightly sealed, chemical-resistant containers to prevent leakage and moisture absorption. The packaging ensures safety and compliance with hazardous material regulations, typically with clear labeling and appropriate documentation. Temperature and handling precautions are maintained to preserve product purity during transit. |
| Storage | Acetone-d6 should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area away from sources of ignition. Keep it away from heat, sparks, open flames, and incompatible materials such as oxidizing agents. Store at room temperature and protect from moisture. Always follow the safety guidelines provided by suppliers like Sigma-Aldrich, Merck, or TCI Chemical. |
Competitive Acetone-d6 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
For decades, the chemical industry has seen demands rise for specialty solvents and isotopic reagents, and Acetone-d6 sits right at the heart of this movement. As a manufacturer who has followed countless batches from raw material through distillation and quality release, our perspective on Acetone-d6 focuses on purity, reliability in application, and transparency in production. This page takes a closer look at Acetone-d6—deuterated acetone—from our hands-on manufacturing experience. We share where the true differences lie, why laboratories continue to rely on this product, and the kinds of trace details that set consistently reproducible Acetone-d6 apart from lower-grade alternatives.
Every batch of Acetone-d6 starts with a tight specification for both starting acetone and deuterium oxide, coupled with a focus on minimized water and protonated acetone content. We have found that even trace levels of regular acetone in the manufacturing stream can create real headaches for researchers relying on a clean, interpretable NMR spectrum. As such, our production crew never considers proton impurity a minor defect. Extended drying and use of inert atmospheres stand as standard protocols, not as afterthoughts. Each run passes through multiple fractionating columns, always watched closely for cuts that impact final purity. Residual moisture and proton content receive continuous monitoring with both in-house NMR and Karl Fischer titration methods.
Our chemists know how Deuterium enrichment (minimum 99.9% D) cannot be taken at face value. Not every supplier’s “99.9% D” rests on the same analytical rigor. NMR spectra, checked batch by batch, show where impurities creep in. We reject anything that drifts from the established baseline. Our technical team maintains logbooks for every run, helping us track historical performance and catch subtle shifts in process. Most of the time, it has not been the big faults but small, repetitive variances that have made the most trouble for our clients.
Over the years, we have fielded requests for Acetone-d6 by model or catalog code, but for us, those are only labels pointing to real, hands-on features. We manufacture Acetone-d6 for analytical use, typically providing it in purity grades tailored for NMR solvent applications (D enrichment minimum 99.9%), but we do not just recite this in marketing material. Real-world experience has taught us that practical parameters matter more: water content routinely below 0.05%, hybridization with protonated acetone less than 0.01%, and packaged under argon to prevent atmospheric moisture pickup.
These are not theoretical figures. Our filling line runs over-pressure argon and custom-sealed ampoules to keep the product as dry as freshly cut glass. Even one misstep in atmosphere control can mean days lost in redistillation and repackaging, so we emphasize tight handling. During scale-up periods, we noticed how cap-sealing and line purge cycles could influence shelf-life. Tweaking these details over time led to longer retention of purity, even on units stored well past their initial date.
In our experience, these differences in floor practice translate to what matters in users’ laboratories—steady chemical shifts, clean signal baselines, and freedom from unexplained background noise in NMR runs. Many of our customers learned this the hard way, after first trying less consistent grades. Returned orders and panicked calls taught us where the bar must be set.
You can read specification sheets all day and not know how small fluctuations in Acetone-d6 can ripple through sensitive NMR or MS workflows. The reason so many high-end academic and pharmaceutical labs demand top-quality Acetone-d6 ties directly to reproducibility. Many compounds under investigation show reactivity not only with trace protons but also with moisture or oxygen. Our long manufacturing record shows that what seems a minor impurity can cascade into ambiguous, difficult-to-reproduce results.
Chemists routinely use Acetone-d6 as a deuterated solvent for proton NMR spectroscopy, especially when focusing on small organics, pharmaceuticals, or natural products. Since every detected proton in the solvent matrix raises background signal, incomplete deuteration obscures or overlaps with sample signals. Our clients count on each bottle to bring signal-to-noise they can trust. Chromatographers sometimes use Acetone-d6 for deuterium labeling studies or to trace hydrogen/deuterium exchange in molecules of interest. Purchasers from biochemistry groups value the low toxicity and high volatility, which makes post-analysis sample cleanup straightforward.
We remain in frequent dialogue with structural biology groups, who clarify that the difference between an unambiguous NMR solvent and a problematic batch lies in trace impurities the manufacturer can control. Many such groups require a long, unbroken supply chain so they can keep using reference spectra over years. Manufacturers like us see these practices up close and know there’s little room for shortcuts.
A comparison between Acetone-d6, standard acetone, and alternative deuterated solvents tells a story the spreadsheets don’t capture. Standard acetone, with normal proton content, creates insurmountable interference for proton NMR and provides none of the spectral transparency necessary for advanced multiplex analysis. Acetone-d6, by contrast, yields a simple multiplet near 2.05 ppm, easily subtracted and nearly invisible in most sample matrices. Competitors often supply Acetone-d6 that seems comparable, but the proof sits in repeat runs. As manufacturers, we have tracked cases where “generic” Acetone-d6 shows slow upticks in water or exchangeable protons after opening, which over time causes escalated background and drift in baseline.
Substitutes such as Deuterated Chloroform or DMSO-d6 bring their own use-cases, but Acetone-d6 offers a distinctive advantage for highly polar solutes and situations demanding low boiling points. For years, we have consulted with researchers frustrated by residue left behind by heavier deuterated solvents. Acetone-d6’s volatility means it leaves almost no trace after gentle heating, opening doors for post-analysis processing or recovery. Unlike chloroform-d, Acetone-d6 does not require stabilizers and brings less health risk. These are details we hear back from customers in medicinal or synthetic chemistry settings, grateful for a less hazardous, easy-to-handle deuterated solvent.
There is yet another difference that often surfaces—a practical issue rather than a chemical one. Acetone-d6 leaves glassware clean and quickly dry, with far less ghosting or memory effect than heavier, less volatile solvents. For multi-sample workloads or high-throughput NMR, this speeds turnaround and keeps cross-contamination to a minimum. Our production team, in regular communication with users at the bench, has built these insights into each batch’s process.
Through years of manufacturing, we witnessed recurring problems from poorly chosen packaging. Acetone-d6’s propensity for atmospheric absorption places real constraints on bulk containers and period-after-opening stability. Our transition from standard caps to sealed ampoules didn’t just satisfy regulatory instruction—it solved practical complaints from users who saw performance drift after weeks or months. We learned to employ thick-walled borosilicate vials flushed and sealed under argon, with tamper-evident labels to discourage careless handling. By moving to smaller fill sizes, we reduced waste and kept per-unit freshness high. Older habits among suppliers favored tin-lined caps or parafilm, but too much solvent slipped past these defenses.
Temperature also impacts Acetone-d6 stability less than some solvents due to its volatility, though repeated warming and cooling cycles can draw in moisture. From a producer’s standpoint, recommending storage at consistent, moderate temperature and away from light proved far more effective than dry-box mandates. Some of our early clients tried bulk containers for cost savings, but springtime humidity spikes unraveled that advantage in days. We revisit packaging decisions annually and consult with long-term clients on what works at their site—a practice often skipped by traders or distributors.
The production of Acetone-d6, with its required use of deuterium oxide and rigorous purification, brings inevitable costs. Tightening purity and minimizing water or proton contamination escalates energy input and labor. Sometimes customers ask why our pricing differs from generic sources. We show them long-term data on water pickup and impurity drift—most see test results for themselves in downstream assays. Technical staff on our factory floor deal firsthand with the balancing act of cost vs. purity. We have made investments in analytical capability not as a sales feature, but as a necessity. NMR and gas chromatography equipment, run daily, back up every lot on record. We maintain detailed archives of spectra, which, if a problem ever arises, allow us to track it to its source.
One overlooked lesson from the manufacturing side involves user education. Early on, we noticed that most chemical leaks or quick degradations in opened Acetone-d6 containers happened outside the plant. To support end-users, we dispatch guidelines on cap replacement, atmosphere minimization, and transfer technique. Some of our best process improvements came from direct customer complaints. Research teams once shared that micro-leaks from thread defects in caps reduced their solvent shelf life. We immediately switched to more robust sealing systems and tracked the outcome over several production cycles, noticing a steep drop in product loss.
On rare occasions, incoming raw materials come with higher residual non-deuterated acetone than previously accepted. In these cases, we halt the batch, rerun purification, and shift supply priorities. This slows things down, but keeps feedback loops from breaking between manufacturing and the research community. Clients often tell us they prefer delay to surprise impurities.
Research methods keep pushing solvent requirements in new directions, and deuterated solvent use has only grown. We see users driving toward lower detection thresholds and broader sample matrices. New applications—ranging from stable isotope labeling to forensics—regularly land in our technical inbox. Our role as manufacturer means forecasting these needs and adapting accordingly. We invest in smaller batch flexibility, modular distillation hardware, and tighter moisture control ahead of shifts in demand. Some academic teams have started using Acetone-d6 in quantum computing and advanced spectroscopy, where environmental control becomes integral to experiment design.
Sustainability also has stepped further into view. Disposal and recycling of solvent waste grows more prominent in labs worldwide. We looked into recycling spent Acetone-d6, both in-house and for select customers, using closed-loop purification where feasible. By reclaiming deuterated material and retreating to high purity, we lower environmental impact and bring down long-term cost for repeat research groups. As these efforts scale, we plan to pair solvent production with recovery and waste minimization—not just to keep in step with regulation but because conscientious stewardship supports everyone using these chemicals, from research assistants to principal investigators.
Global supply chains change quickly, and ensuring unbroken availability for such a specialized solvent takes real focus. We diversify sourcing of precursor acetone and deuterium oxide, hold redundant supply routes, and keep proactive communication with NMR centers during spikes in demand. In the last few years, disruptions in logistics made us double down on inventory monitoring, batch traceability, and technical support.
As a direct manufacturer of Acetone-d6, our reputation builds not just on delivering bottles promptly, but on standing behind each batch with technical transparency and a willingness to adapt. Genuine familiarity with the chemistry and everyday realities of customer workflows bridges the gap between technical specification and successful application. We remain committed to helping researchers get the best results from every experiment, not simply selling solvent.
Across analytical, pharmaceutical, and academic settings, expectations continue to rise for solvent integrity, trace impurity control, and user-centric packaging. Through continual process improvement, direct dialog with end-users, and persistent investment in distillation technology, we work to deliver Acetone-d6 that consistently exceeds expectations and supports the broad ambitions of modern science.