West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

5-Fluoro-5'-deoxycytidine

    • Product Name 5-Fluoro-5'-deoxycytidine
    • Alias FCCyd
    • Einecs 691-224-3
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    206611

    Product Name 5-Fluoro-5'-deoxycytidine
    Chemical Formula C9H12FN3O4
    Molecular Weight 245.21 g/mol
    Cas Number 134898-86-1
    Appearance White to off-white powder
    Purity Typically ≥98%
    Solubility Soluble in DMSO and water
    Storage Temperature -20°C
    Synonyms 5-F-5'-dC, 5'-Deoxy-5-fluorocytidine
    Structure Type Nucleoside analog
    Iupac Name 4-amino-5-fluoro-1-[(2R,4S,5R)-4-hydroxy-5-(hydroxymethyl)oxolan-2-yl]pyrimidin-2-one
    Usage Research in nucleoside metabolism and anticancer studies

    As an accredited 5-Fluoro-5'-deoxycytidine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 5-Fluoro-5'-deoxycytidine (Sigma Aldrich, 100 mg): Supplied in a sealed amber glass vial with tamper-evident cap and labeled for chemical use.
    Shipping 5-Fluoro-5'-deoxycytidine is shipped in tightly sealed containers to ensure product integrity, protected from moisture and light. The chemical may require cold packs or ambient shipping, depending on stability data. All packages comply with relevant chemical transportation regulations, including proper labeling and documentation for laboratory research use. Check local import restrictions before ordering.
    Storage 5-Fluoro-5'-deoxycytidine should be stored at -20°C, protected from light and moisture, in a tightly sealed container. The chemical is typically supplied as a powder or solid. Store in a dry, well-ventilated area, away from incompatible substances such as strong oxidizers. Ensure the storage area is equipped for handling hazardous laboratory chemicals, following the supplier’s safety recommendations.
    Free Quote

    Competitive 5-Fluoro-5'-deoxycytidine prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    5-Fluoro-5'-deoxycytidine: A Practical Approach from a Manufacturer’s Bench

    Understanding the Compound in a Working Lab

    Every day in production, small differences in molecules determine which direction a project will head. 5-Fluoro-5'-deoxycytidine stands out as one of those nucleotide analogs. It steps into ongoing lines of research for epigenetics, oncology, and DNA methylation studies. Unlike classic cytidine analogs, its fluorinated structure changes enzyme recognition and metabolic fate, opening routes for biochemistry projects we see rising in the labs we serve.

    Over years of manufacturing nucleosides, we’ve noticed that the careful addition of fluorine can mean the difference between a versatile research tool and a redundant standard. Our chemists produce 5-Fluoro-5'-deoxycytidine by controlled fluorination and protection strategies, ensuring a single isomer form. In QC, this means we look for tight purity, measuring by HPLC, with residual solvents below the regulatory trace levels so reproducibility stays within the hands of each scientist. Our batch records document everything: from raw intermediate quality to actual fluoride source and reactor parameters, so that we don’t gamble worker or researcher trust.

    Model, Purity, and Material Appearance

    This compound appears as a white to nearly white crystalline powder, with a molecular formula of C9H12FN3O4. The recent lots typically offer purity above 98%—we routinely surpass this, since our batch controls and purification protocols favor a single product and work up practical yields. Moisture level speaks to how well it has been handled, so our warehouse checks loss on drying using Karl Fischer titration. Real-world purity varies not just lot to lot among different manufacturers, but within shipping itself; we lock down the packaging against humidity and avoid broad generic plasticware, choosing materials that have proven unreactive in stability tests.

    Researchers buying this molecule from our facility see the differences in physical handling. The powder flows clean, fine without clumping, leaving no visible yellowing or off-odors—signs that would scream impurity or oxidative breakdown. Over the years, we have learned to avoid certain solvents during workup, which minimizes any detectable traces by the time it reaches the end user. Lab-to-lab, these small details prevent recurring headaches during cell culture or stock solution preparation.

    Why Use 5-Fluoro-5'-deoxycytidine? Practical Value in the Field

    Where normal cytidine analogs often fall short—either stuck in classic metabolism or hitting old, saturated research targets—5-Fluoro-5'-deoxycytidine steps into new territory. The solitary fluorine at the 5-position tweaks base-pairing and changes the way polymerases handle DNA. In our experience supplying to methylation research, this chemical enables precise disruption of DNA methyltransferase activity without the instability seen in other analogs.

    We’ve seen principal investigators repeatedly turn to this compound for in vitro assays targeting gene silencing. The absence of a 5’-hydroxyl group distinguishes it; this seemingly minor switch prevents regular phosphorylation, making it less susceptible to standard kinases, yet the fluorine preserves enough base recognition for effective incorporation by specific polymerases and enzymes. In hands-on work, this feature means the analog either stalls a reaction or becomes a controllable blocking point, rather than introducing unwanted off-target effects. That aspect keeps researchers returning for follow-up lots.

    Cell biologists pursuing anti-cancer pathways turn to this compound to probe nucleic acid synthesis, as it mimics cytidine but offers more specific downstream behavior in proliferation assays. As a manufacturer, we hear feedback about cell uptake and assay consistency—each shipment, scientists count on a narrow melting range and consistent solubility. We monitor reports about batch variability in the industry, and alter our handling protocols to reduce potential sources of error.

    The experience of handling, packaging, and shipping hundreds of lots reveals one theme: purity and trace impurity, including sodium or chloride ions from washing steps, can have outsized effects on cell response profiles. No matter how pure a certificate may read, solvents in glassware or water in packaging yields day-to-day trouble if neglected. We double-check every lot post-packaging, knowing that even a small deviation in crystal structure or particle size upends an entire week's worth of assay work.

    Key Differences and Technical Comparisons

    Years of bench-level comparison underscore what separates 5-Fluoro-5'-deoxycytidine from analogs like 5-Azacytidine or Decitabine. By skipping the 5’-hydroxyl, this nucleoside cleaves differently under enzymatic attack and doesn’t insert into the same metabolic pools. Enzymes that typically phosphorylate native cytidines can’t easily use this substrate. In DNA methylation projects, that sidestep allows researchers to block methyl group addition with greater control—useful in mapping methylome function or studying epigenetic drug candidates.

    Most commercially available cytidine derivatives insert an azido or methyl group, shifting the research focus slightly. The fluorine atom of 5-Fluoro-5'-deoxycytidine imparts higher resistance to aqueous and thermal decomposition; this translates into broader storage options and less degradation over long-term studies. Our team tested stability under varying humidity, room temperature, and light exposure, logging a slower breakdown curve compared to nitro- or azido-modified nucleosides. Less technical loss means improved economy at scale.

    Sometimes the litmus test comes down to the day-to-day physical manipulation. Analytical teams report pipetting batches of this product without gumming, aggregation, or static build-up that comes from less pure sources. HPLC chromatograms appear cleaner, and downstream synthesis of oligonucleotides using automated synthesizers reveals higher couplings per cycle. Our own records show that stirrability and suspension preparation hold steady over years of lots, even with minor seasonal fluctuations in ambient storehouse humidity.

    Manufacturing Realities and Process Controls

    As a manufacturer, success comes down to synthesis reliability and repeatability. The core chemical process begins with cytidine modification, where selectivity during fluorination and deoxygenation stages determines impurity spectrum. We use column chromatography, recrystallization, and thin-film drying—not shortcuts or mass crystallization, which inject unsafe levels of byproducts. Each step receives active monitoring for side products, employing NMR and mass spectrometry so that nothing unexpected rides along into finished packaging.

    Over the years, we learned that reactor vessel material, temperature gradients, and even the finish of glassware have real effects. Stainless steel vessels introduce traces of iron during harsh fluorination; glass, despite its inertness, risks minuscule fractures with repeated cooling cycles. We change out reaction vessels on a fixed schedule motivated by actual data, not generic upkeep. Environmental controls extend to solvent recovery, ensuring recycled organics don’t carry-over trace contaminants from batch to batch.

    Post-process, we engage in stability audits. Accelerated stability testing—cycling through freeze-thaw and warm-humid scenarios—provides snapshots of the molecule’s shelf behavior. The findings prompt us to use triple-layer packaging for certain destination climates. In regions with logistical uncertainty, we include desiccants and tamper indicators, so the practitioners receiving the goods start their assay under the same conditions as the previous lot.

    Regular feedback loops between production and application teams allow for batch-specific technical support. No robot or online template replaces a live scientist’s troubleshooting on crystallization, solubility, or solution prep. The difference perhaps seems invisible in a catalog, but in daily bench use—and given thousands of endpoint results delivered from our compound so far—the distinction in process and responsiveness creates a far lower rejection rate and smoother customer experience.

    Applications and Real-World Results

    Over a decade of synthesis, researchers using our 5-Fluoro-5'-deoxycytidine have published on DNA methylation inhibitors, cell line-specific epigenetic modulation, and as a component for oligonucleotide probe development. In cancer cell biology, altering DNA synthesis with this analog produces unique growth inhibition. We read reports on applications ranging from PCR blocking to site-directed mutagenesis, finding that selectivity and controlled reactivity matter more for end users than crude price or standard catalog language.

    Some clients run high-throughput screening. We calibrate our lots for bulk, uniform scale, and run side-by-side tests with older or competitor products. The outcomes shape process improvements: better filtering, closer purity checks, and more detailed outgoing documentation. On the bench, we see scientists reducing failed runs, with cleaner reaction baselines and higher data reproducibility.

    Students, postdocs, and industry scientists bring fresh questions, sometimes requesting modifications—different salt forms, bulk shipments for kilo-scale synthesis, or enhanced certificates of analysis for regulatory submission. Our team adapts manufacturing runs, sometimes splitting lots or preparing special packaging for sensitive storage in academic repositories. These hands-on requests come only because our workflow has flexibility, rooted in in-house expertise and validation data.

    Not every application needs the highest attainable purity, but the same real-world issues pop up: unwanted peaks on HPLC, strange odor on opening, or unexplained cell culture results. By directly integrating customer feedback, technical incident logs, and actual researcher experiences, we trace back such troubleshooting to either packaging, reagent stability, or unnoticed process drift. Timely adjustments on our end mean fewer technical corrections for users later.

    Solving Problems: Lessons Learned as a Manufacturer

    Manufacturing 5-Fluoro-5'-deoxycytidine isn’t free from challenges. A recurrent issue involves maintaining consistent fluoride incorporation without causing side reactions in the deoxy position. We’ve refined process steps, incorporating in-process NMR to verify substitution before isolation, to limit the formation of closely-related impurities. Purification presents its own headaches: overuse of certain solvents creates solvate inclusions, so we switch solvents mid-course and compare endpoint impurity by batch. After years of feedback and real-world problem-solving, our protocols rotate through setups with the lowest historical deviation.

    Another challenge remains in global logistics. Fluctuating regulations, customs checks, and seasonal humidity all bite into chemical stability. We now vacuum-seal and multi-layer every package, and flag batches for redelivery if a shipment veers into extended customs hold. Fielding customer calls on such issues builds trust—instead of standard form letters, our technical staff relays lot-specific guidance, including how to re-crystallize or check material integrity in house.

    Quality documentation differs for each customer’s purpose: pharma, academic, or industrial. We build each set from production chromatography, impurity testing, and storage validation, reducing generic statements. With years invested, our records speak to every technical claim and respond to emerging regulatory norms.

    Years ago, unexpected precipitation after cold chain delivery upended a research group’s project. The issue traced back to residual solvent trapped from a sub-step in purification. That story convinced us to slow down the drying step, enlarging our cold storage for slow evaporation under vacuum rather than a fast push; since then, those precipitation notes evaporated from our support inbox.

    Feedback cycles between us and end users—transparent and technical—caught early signs of oxidative instability in a few lots. Adjusting our packaging and tightening environmental controls reduced such incidents close to zero.

    Improving the Path Forward: Advanced Inquiry and Support

    Research is rarely static. Customers ask not only for the chemical, but for validation data attuned to new bioassays and regulatory audits. We treat these requests as normal business, not add-ons. Over time, requests for more granular NMR spectra, UV-Vis results, or formal stability studies drive us to expand our analytical database. This helps researchers preparing for grant applications, publication, or regulatory submissions.

    Requests for scaling up—moving from milligram to kilogram—have pushed our process development. Increasing yield while holding impurity at the same low level challenges reactor design and solvent recovery. Our scale-up laboratory mirrors large production processes, not pilot-size models, uncovering constraints in heat transfer and agitation, especially with dense slurries. The effort to match small-lot grade at bulk scale sets real chemical manufacturing apart from mere resellers or repackers.

    We maintain open technical lines for feedback, including results from less conventional research—like gene editing modification, next-gen sequencing, or synthetic biology constructs. If a researcher uncovers a truly novel application or encounters unexpected cross-reactivity, we track the report and triage with on-site chemists to adapt next batches. Our adaptation rate, proven by historic logs, closes the gap between classical chemical supply and real-time scientific advancement.

    Reflections as a Long-Term Manufacturer

    Decades of day-in, day-out production have shown us that true quality in research chemicals comes from internal control, transparency, and responsive adaptation. 5-Fluoro-5'-deoxycytidine reflects these lessons. From careful sourcing of every starting raw material, through cautious scale-up, to iterative improvement based on real-life experience, we’ve watched the material shape workflows in DNA methylation studies, epigenetic screens, and synthetic oligonucleotide production.

    Continuous improvement isn’t a buzzword in our factory. It means realizing that a ten-minute drying shortcut might cost someone three weeks of failed assays halfway around the world. Tweak the solvent, slow the reagent addition, or adjust the filtration—not for broad, anonymous sales figures, but because we know which tweaks prevent which headaches. Regular communication with users—sharing new findings, odd impurity reports, or latest storage best practices—cements the chain between producer and scientist.

    Rather than focus on generic catalog marketing speak, we know the customer on the other side of the shipment needs reliability, not just stated purity. Whether it’s a student running the first test or an established PI pursuing a new therapy target, we treat each lot as an opportunity to get the details right, supply actionable documentation, and adapt for novel challenges—supporting every serious inquiry direct from the bench.