|
HS Code |
733295 |
| Name | 5-Ethynyl-2'-deoxyuridine |
| Abbreviation | EdU |
| Chemical Formula | C11H12N2O5 |
| Cas Number | 61135-33-9 |
| Appearance | White to off-white powder |
| Solubility | Soluble in DMSO and water |
| Storage Temperature | -20°C |
| Purity | Typically ≥98% |
| Application | Cell proliferation assay |
| Synonyms | EdU, 5-ethynyl-2'-deoxyuridine |
| Iupac Name | 1-[(2R,4S,5R)-4-hydroxy-5-(hydroxymethyl)oxolan-2-yl]-5-ethynylpyrimidine-2,4(1H,3H)-dione |
| Melting Point | 196-198°C |
| Bioactivity | Incorporates into DNA during active DNA synthesis |
| Hazard Statements | May cause irritation to eyes, skin, and respiratory tract |
As an accredited 5-Ethynyl-2'-deoxyuridine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 5-Ethynyl-2'-deoxyuridine, 100 mg, supplied by Sigma Aldrich, packaged in an amber glass vial with a sealed cap. |
| Shipping | 5-Ethynyl-2'-deoxyuridine (chemical grade) from Sigma Aldrich, Merck, or TCI is shipped in sealed, light-protected containers to prevent degradation. It is typically transported as a solid at ambient temperature with careful labeling and handling, complying with chemical safety regulations to ensure secure and compliant delivery. |
| Storage | 5-Ethynyl-2'-deoxyuridine (EdU) should be stored at -20°C, protected from light and moisture, in a tightly closed container. The chemical is stable under recommended storage conditions. Avoid repeated freeze-thaw cycles. Always use with proper personal protective equipment, and handle in a well-ventilated area. Refer to the manufacturer’s safety data sheet (SDS) for additional storage and handling information. |
Competitive 5-Ethynyl-2'-deoxyuridine prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
On the manufacturing floor, there is no illusion when it comes to a molecule like 5-Ethynyl-2'-deoxyuridine (EdU). From batch synthesis to vial filling, scrutiny is relentless. Every crystal matters because tiny fluctuations in impurity levels or yield can scramble results in downstream research. We learned the value of tight controls early. Only through relentless monitoring do we achieve a product that matches not just the published assay numbers, but also researcher expectations for real experimental reliability.
Our process for EdU starts at raw material procurement, where DNA-grade reagents carry hard-won certifications. Minor issues in purity, once overlooked in less sensitive settings, now stick out sharply under the lens of cellular and molecular biology. Even trace contaminants can confuse cell proliferation assays or cause cytotoxic side effects. That is why purification stands out as a key battlefront. Solid-phase extraction, repeated recrystallizations, and rigorous chromatography protocols remove those anomalies so each lot stacks up to the one before it.
Over years of scaling up from gram to multi-kilo lots, we have dug through production pinch points. For EdU, solubility in aqueous buffers comes up in early conversations with clients in genomics labs. We see the benefits of a product that dissolves quickly and predictably, making dosing consistent. Those handling thousands of samples a week report frustration when clumping or incomplete dissolution wastes hours or spoils plates. By tuning particle size and hydration during isolation, we aim to sidestep those issues before the vials ever leave this site.
On our production reports, each release carries numbers that tell a story beyond mere catalog listings. EdU runs typically deliver a white to off-white powder, with HPLC purity tested above 99%. Water content matters, so every batch runs through Karl Fischer titration, keeping moisture tightly controlled. Spectroscopic fingerprints—1H NMR, 13C NMR, and mass spectrometry—all line up with reference spectra. These checks matter for traceability and reproducibility, not just because of regulatory needs, but because our clients have called for no less.
We carry EdU as CAS 196912-88-8, and the molecular formula C11H12N2O5 matches the specs required for most research uses. Standard batch sizes run from hundreds of milligrams for academic groups to kilogram-scale for kit makers and core facilities. Packaging in amber glass or inert-lined vials matters to prevent photodegradation or adventitious contamination.
Solvents are chosen to avoid reactive residues. DNA labeling isn’t forgiving; even a chemical trace could trigger false positives or misleading cell viability signals. Analytical certificates accompany every order, with full methods documented. More than once, we’ve fielded late-night emails from postdocs frustrated by inconsistent results—from competitors’ lots. The rigor in specification comes not from checking boxes, but from real feedback after long days at the bench.
EdU changed how researchers monitor cell division and DNA synthesis. Before EdU, bromodeoxyuridine (BrdU) held the standard position in proliferation assays, but it required harsh DNA denaturation steps for detection. These treatments compromise sample integrity, knock antigens loose from their contexts, and complicate downstream immunostaining. EdU sidesteps most of those issues. The ethynyl moiety at the 5-position hooks into click-chemistry detection—especially copper-catalyzed azide-alkyne cycloaddition. This enables a one-step, highly specific fluorescent labeling without destroying DNA structure or framework proteins.
Users in neurobiology, oncology, and developmental biology labs rely on EdU for single-cell, high-throughput applications. They cite the time savings, ease of multi-parametric analysis, and improved preservation of tissue architecture. Our own internal R&D division put EdU against other analogs and documented reduced cell death in sensitive murine brain slice cultures using EdU protocols compared to BrdU. The quantifiable drop in background signal meant clearer imaging and more confident interpretation of cell cycle data.
While BrdU’s slot in textbooks remains, feedback from the research trenches shifted rapidly. As a manufacturer, we respond not just to orders, but to requests for lot-specific performance comparisons. Our technical team compares batch trace files and performance metrics from users developing EdU-based high-content screening. We use their feedback to tweak particle size distribution and solvent compatibility in future batches.
Across eight years shipping EdU to hundreds of labs, we’ve witnessed its application stretch wide—single molecule DNA replication studies, pulse-chase cell fate mapping, in vivo tumor xenografts, stem cell tracing, and high-throughput cytometry. Downstream users depend on our product to reliably integrate into DNA during S-phase without crossing into cytotoxicity at recommended concentrations.
The molecule itself remains robust across a range of eukaryotic cell lines and model organisms, from yeast to zebrafish to mammalian systems. Researchers looking to track neurogenesis, leukocyte differentiation, or tissue regeneration benefit from predictable batch performance. EdU’s copper-catalyzed click chemistry detection delivers robust fluorescence in both fixed and live-cell settings. Collaborations with core imaging facilities continually reinforce the value of lot-to-lot consistency.
During COVID-19 disruptions, supply chain interruptions pushed users toward unfamiliar suppliers. Some received variable results from outside makers—clumping in solution, inconsistent DNA signal, or unexplained toxicity on delicate primary cultures. These moments sharpened our commitment to keeping core steps in-house and investing in rigorous end-of-line QA.
EdU comes up in compliance forums for another reason—its purity and integrity have downstream impact on clinical and translational research. Reagents for tracking cellular proliferation often feed into diagnostic or even preclinical workflows. Our hands-on team oversees audits for cGMP or ISO certifications. Each iteration of the process traces a chain of custody, all the way from raw input to final shipment.
No factory worker relishes redoing a step or discarding an out-of-spec batch. The cost of error grows as scale increases, not just financially but in lost research time for end users. That’s why every batch goes through trace heavy metal analysis, residual solvent profiling, endotoxin screening, and microbial contamination checks. End users in critical settings—hematology and stem cell labs—have zero tolerance for slip-ups.
During an episode in 2022, we traced a minor spike in residual copper ions, attributed to upstream solvent contamination. The lab flagged it before bottles left the site, saving customers from headaches or wasted experiments. These lessons linger in the institution’s memory, driving regular review of cleaning protocols and incoming raw material checks.
EdU may sound the same when ordering from multiple sources, but long-time users know better. Particle size, polymorphic form, residual metals, and stability under shipping can create small but critical splits between performance in the dish and raw supplier COAs. Our path has been to avoid relabeling another’s product and instead control each step—from synthesis to QA. We do not cut corners by using technical or industrial grades; we stick to pharmaceutical-grade starting materials and certified UV-protective packaging.
Anecdotally, customers switching from cheaper imports have shared data showing higher consistency of S-phase labeling and less cellular stress across parallel cultures. Our own testing corroborates these findings. Users find that our EdU dissolves faster, with less agitation, at standard stock concentrations—saving prep time in high-throughput settings. Consistency in purity isn’t just cosmetic: it shows in reduced background signal and improved statistical power across replicates.
BrdU substitutions continue in some labs, but the value shifts rapidly in favor of EdU once researchers weigh procedural simplicity and sample preservation. Chlorodeoxyuridine or iododeoxyuridine sometimes fill niche needs, but none match the specificity and minimal processing steps EdU delivers. We track these developments in the literature and customer feedback alike, keeping an adaptive approach to both R&D and end-user tech support.
Shipping sensitive reagents poses its own hurdles. EdU degrades with UV exposure and excess moisture. We established a network of cold chain logistics partners and use amber vials, packing under inert gas with desiccant. Clients have testified that vials from our factory arrive with clear instructions and last through repeated freeze-thaw cycles, with no measurable drop in reactivity.
Shelf life monitoring goes beyond simple registration. Batches are re-tested by our QC team at six-month intervals, alerting us if any hints of instability emerge before those bottles reach a bench. Vigilant product stewardship means troubleshooting at the first sign of off-spec results, not after customers have lost days of work. Several groups have caught potential product batch issues not from manufacturing origin, but from improper downstream storage at local depots. Our support staff help them identify root causes, often providing fresh batch samples at no cost.
Feedback directly influences manufacturing adjustments. Instances of slower than expected dissolution led us to pilot a control on particle morphology. Reports of rare toxicity in specific cell types prompted a fresh round of endotoxin and heavy metal checks. Each story translates into adjustments, not just internal memos or QA paperwork.
Many first-time EdU users need guidance along the way—help with reconstitution, recommended concentrations for various cell types, fixative compatibility, and troubleshooting of click reaction conditions. Through our technical hotline and resource pages, we address these knowledge gaps directly. There are few shortcuts in pushing researchers up their learning curve. Failures in labeling often stem not from the product, but from mismatches in buffer systems or erroneous protocol tweaks.
We started hosting user webinars, collaborating with principal investigators to build robust standard operating procedures. Missteps with copper-catalyzed click chemistry or improper buffer pH routinely led to inconsistent signal intensities. After launching a peer support forum, we saw knowledge spread faster—reducing both frustration and wasted reagent.
Out of hundreds of support cases, less than five percent focused on the product quality itself; most stemmed from procedural questions or specimen handling artifacts. This feedback loop gives us confidence that manufacturing reproducibility stands strong, but vigilance remains necessary.
Medical research increasingly draws links between basic cell cycle studies and diagnostics. EdU now takes part in pilot clinical sample labeling for rare leukemias, tumor stem cell identification, and regenerative medicine protocols. Here, the research setting’s demand for single-cell resolution and gentle processing steps puts extra demands on our quality system. The opportunity to impact outcomes makes every production run meaningful.
Translational partners ask about scalability, lot reservation, and detailed traceability for regulatory submissions. In response, our documentation covers each batch’s lineage, analytical results, and storage history. Production engineers meet frequently with regulatory liaisons, updating controlled documentation to match shifting expectations. We also openly encourage audits and sample testing from external laboratories.
Adapting to translational needs strengthened our internal training. During onboarding, chemists spend time in both QA and customer support, learning not just reaction kinetics and drying curves but also the downstream effects of any misstep—spanning from a single failed experiment in a university lab to potential setbacks on new diagnostic technologies.
We closely monitor advances in nucleoside analogues and detection methods. Research into copper-free click chemistry, or next-generation dyes, could further increase EdU’s utility and safety. Our formulation team experiments with alternative buffering salts and lyophilized formats for custom partners conducting field work. As biotechnology trends shift, flexibility in packaging and documentation can matter as much as the product’s chemical skeleton.
Emerging needs for multiplex labeling and real-time cell cycle tracking pushed us to collaborate with dye and probe suppliers. Integration with high-content imaging requires that EdU’s purity and reactivity don’t introduce noise or background. Product development meetings regularly review feedback from frontline researchers, adjusting manufacturing priorities to best serve new assay formats.
From a process perspective, we invest in smart automation and enhanced process controls. Batch records now use digital tracking, with redundant backup of spectra and chromatograms. Scientists in the manufacturing area cross-train on batch analysis, synthesis, and downstream support, closing any gaps that could let product drift slip by. Each lot becomes a learning opportunity.
Looking back, the importance of hands-on oversight stands out at every stage—from receiving starting materials to packing final orders. Keeping faith with research customers means more than dropping a product on a cart and shipping it out. Every batch of 5-Ethynyl-2’-deoxyuridine goes through the hands, eyes, and judgment of staff whose reputation relies on uncompromising standards and attention to emerging user needs.
We take pride in the feedback loop running from cell culture labs and imaging cores back to our factory floor. Reality checks from users facing real deadlines push the company to refine, troubleshoot, and rededicate itself. The story of EdU isn’t just about nucleoside chemistry or click reactions—it's the sum of lessons learned, improved, and passed on between those who engineer its synthesis and those who pursue the next scientific milestone.