|
HS Code |
682082 |
| Product Name | 4-(Dimethylamino)butanoic acid hydrochloride |
| Molecular Formula | C6H14ClNO2 |
| Molecular Weight | 167.64 g/mol |
| Cas Number | 20046-20-2 |
| Appearance | White to off-white crystalline powder |
| Melting Point | 120-124°C |
| Solubility | Soluble in water |
| Storage Conditions | Store at room temperature, tightly closed, protected from moisture |
| Ph | Approximately 3.5-4.5 (1% solution in water) |
| Synonyms | DMABA hydrochloride; γ-(Dimethylamino)butyric acid hydrochloride |
| Purity | Typically ≥98% |
| Smiles | CN(C)CCCC(=O)O.Cl |
| Inchi Key | NVNBBAXVJWDUCP-UHFFFAOYSA-N |
As an accredited 4-(Dimethylamino)butanoic acid hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | White plastic bottle with screw cap, blue Sigma-Aldrich branding, labeled “4-(Dimethylamino)butanoic acid hydrochloride,” 25 grams, safety data included. |
| Shipping | 4-(Dimethylamino)butanoic acid hydrochloride is shipped in tightly sealed containers to prevent moisture absorption and contamination. It is typically packed and labeled according to regulatory standards (including GHS/OSHA), and shipped at ambient temperature unless otherwise specified. Consult the supplier’s SDS for specific shipping precautions and any hazard classification details. |
| Storage | 4-(Dimethylamino)butanoic acid hydrochloride should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area, away from direct sunlight and moisture. Keep the chemical away from incompatible substances such as strong oxidizing agents. Store at room temperature or as specified by the manufacturer (typically 2-8°C). Follow all safety guidelines provided by Sigma Aldrich, Merck, or TCI. |
Competitive 4-(Dimethylamino)butanoic acid hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Producing 4-(Dimethylamino)butanoic acid hydrochloride demands focus from raw material sourcing to finished product. Each batch undergoes tight process control, since performance often hinges on subtle details. While the IUPAC name sounds technical, the route to making fine intermediates like this remains rooted in real chemical know-how. Experience shows us purity is the difference between a product that supports precise outcomes and one that sits on the shelf as dead inventory. For this compound, our method minimizes byproduct formation from overalkylation and oxidation, staying away from generic shortcuts. Based on collected data from years of troubleshooting, that process consistency lets us consistently meet a 99%+ assay on a batch basis.
We don’t see this as just an intermediate. Over time, pharmaceutical clients have shared feedback about projects stalling from inferior batches. Common culprits are excess dimethylamine or residual solvents, leading to regulatory headaches and failed downstream reactions during synthesis. We chase those impurities out, using a controlled crystallization step and then full batch-by-batch gas chromatography verification. We believe in sharing batch data when asked, since nobody should buy from guesswork.
Choosing the hydrochloride salt isn’t just tradition in chemical manufacturing; it addresses real stability and handling needs, especially for sensitive research and scale-up. Chemists in pharmaceutical discovery prefer the hydrochloride version for its improved shelf stability, better solubility in polar solvents, and ease of weighing and dosing. Our technical staff run accelerated stability studies to back claims about long-term storage. While you might find other salt forms or free acid versions on the market, those often degrade, change color, or cake up after a few cycles in the open air. We've compared batches side by side and found hydrochloride's resilience beats them every time.
Bulk users in peptide and small-molecule research tell us the HCl version saves time and cuts down on lost intermediates during workup. It avoids the mysterious yield loss so many engineers see when using lower-grade, less stable forms. If you’re doing peptide synthesis, you know how even trace instability or hydrolysis in the starting material can throw off the entire chain. Our quality checks catch degradation before it enters your synthesis pipeline. That’s not just theoretical — we trace and document stability for standard temperature/humidity cycles, so scale-up doesn't become a worry.
This material exits our reactors as fine, white crystalline solid, with moisture levels under 0.5% and a targeted particle size distribution controlled during our drying phase. Our process incorporates in-line milling and sieving for size uniformity, which directly supports consistent solubility and reproducible dosing in both lab and pilot-scale reactors. We know clumping and poor dispersion can rack up costs in failed batches; our design avoids these frustrations.
Breaking away from one-size-fits-all, we offer standard mesh grades (D50: 100-200 microns). Over time, we’ve had feedback from formulation scientists and found this size avoids dust issues without producing hard-to-dissolve clumps. Even minor tweaks in particle handling time add up when you’re charging reagents in a busy pilot plant. Moisture is tightly controlled since minor overdrying affects compaction, and excess water risks hydrolytic decomposition. We monitor real-time as materials move through the drying tunnel, so that every drum matches tight specifications.
We handle the hydrochloride salt with typical precautions for amine intermediates. There’s no substitute for keeping the product away from strong bases, and ensuring containers are air-tight between uses. Our operators found standard polybags degrade too quickly, so we use multi-layer packaging designed to keep air and moisture out — a lesson learned after years of fielding complaints from labs about caking and color shifts in material from less careful suppliers. Each lot lives in vapor-barrier bags within fiber drums, so the last user pulls the same material quality as the first.
Loaders and shippers often notice dusty batches create workplace challenges, so we keep the product dust-suppressed and regularly inspect for contaminated seals or broken liners. A properly packed hydrochloride salt holds up for more than a year, even with regular opening and resealing under typical storage conditions. That’s a difference you discover in daily practice, not on a spec sheet.
We’ve watched as 4-(Dimethylamino)butanoic acid hydrochloride made its mark across research, pilot, and even a few commercial syntheses. Its place in organic synthesis, especially medicinal chemistry, stands out. Many pharmaceutical researchers use it as a protected amino acid spacer during peptide bond formation and conjugation reactions. The dimethylamino handle offers reactivity for further derivatization, while the four-carbon chain delivers the right balance of flexibility and steric profile for linkers and active groups in lead candidates. Contract manufacturers often rely on our material for SAR programs, where small shifts in purity trigger costly side reactions down the line.
Beyond pharma, specialty surfactants and fine chemical producers find value in the compound's mix of lipophilicity and water compatibility. The hydrochloride helps with ease of weighing in multi-step synthesis. We’ve listened to users who shared how switching from free acid to hydrochloride cut weighing time by 20% and reduced sample loss from static. Our team sees these “small” things as big returns during kilo-lot and multi-ton scale.
Many suppliers offer intermediates that appear similar on a data sheet, yet repeated use reveals critical differences. We build every batch for researchers and process chemists who see the downstream impact of surface impurities or water uptake. We select raw material sources for low nitrosamine risk. Every vessel and pipe is in regular rotation, never forced to sit idle or run occasional side jobs, so there’s no chance of unexpected contamination from older intermediates.
We don't risk “run to depletion” practices — never skimping late in the campaign by stretching out reactor runs when impurity buildup is at its peak. This means near-zero off-odor events, no unexpected color changes, and full, documented conformance to typical pharmacopeia standards. Tighter particle size control, real gas chromatography, and attention to solvent residues all reflect manufacturing lessons learned over time. Tank cleaning, operator retesting, and preventive maintenance show up in the little things, but make all the difference in what you get.
Our team collects feedback on each shipment, tracking field triggers like failed reactions or drifting pH that may point back to overlooked batch problems. We change methods based on these observations. The plant team investigates every deviation, not waiting on complaints before fixing root causes.
We often hear from researchers who have tried generic forms of this compound. Free acid versions or their sodium salts frustrate teams with shelf life and handling complications. The hydrochloride proves more robust in formulation and easier to integrate into existing workflows. Others supply a mixed fraction, leading to unpredictable results as product purity varies across the drum. Without in-line particle control and moisture scrutiny, these batches turn clumpy and sometimes “go off” after transportation.
Some products come from plants set up for volume, not care: we’ve sourced competitor material that shows inconsistent performance due to variable crystallization times and impurities. You’ll notice more off-spec odors, erratic pH in solution, and crystalline dust that fouls up charging lines. These details don’t reveal themselves on a TDS or standard COA, but they matter immediately at scale.
We value onsite batch verification because it keeps feedback loops tight. People sometimes assume a purchased COA means full compliance, yet small changes pass unnoticed unless you run the same NMR, GC, and stability checks yourself. We send representative samples to technical teams, even before formal orders, letting process engineers judge performance during trial runs.
With batch traceability embedded in our system, every complaint or inquiry matches right back to a documented trial or analytical run. Our quality manager reviews deviation logs, and if a trend appears — like elevated byproducts or shorter retest intervals — we investigate and use the learning to upgrade standards before issues become shipment-wide headaches. This approach earns trust slowly, but saves expensive clean-up later.
Our technical support often fields calls from chemists searching for reliable batches, having fought through failed reactions or regulatory blockages from trace impurities. Years back, our largest pharma customer traced a stalled preclinical project to inconsistent amine output; repeated testing uncovered side reactions seeded by a minor residual in poorly washed material from another source. After troubleshooting, we implemented extra washing and filtration during our process, so that kind of setback doesn’t reach other teams.
It pays to pay attention to the fine print: pH, trace base, and particle size all end up playing larger roles than just the numbers. Our technical group audits every run, and continual small tweaks — like air sweep adjustments in the dryer and calibration of milling screens — add up in reliability. As volume grows, repeatability matters most, for kilo-scale reactions or when planning full campaigns. Skipping corners early accumulates real and preventable expense.
While product specs matter, on-the-ground experience proves some features matter more than others. Purity above 99% is commonly requested, but equally important are real batch uniformity, manageable bulk density, and tight particle size distribution. Instead of flooding the page with generic test values, we see the best judge as repeat usability in process environments. Few appreciate that even a 0.5% deviation in water or dimethylamine content can cripple scale-up yields or cloud regulatory submissions.
Batch-to-batch reproducibility is where generic competitors falter. Every container shipped from our line gets weighed, sealed, and stored under N2 or dry air, limiting oxidation and caking risk during global transit. This comes from our history of chasing down small faults that escape less serious producers.
Working as an actual producer puts us in the hot seat for regulatory reviews, audits, and customer investigations. We audit our own documentation regularly and keep transparent records. Our analytical packages — covering NMR, Karl Fischer water, elemental analysis, and metal content — meet the submission needs for regulated pharma customers.
Team members take pride in fixing problems early; not waiting for buyer complaints. If a specification slips, we pivot to root-cause analysis. We prefer upgrading batch filtration or reactant QA, rather than reprocessing or downgrading shipments. Tight upstream checks on raw amines and acids, validated cleaning protocols, and regular plant audits protect every downstream partner relying on our consistency for their own compliance.
We hear from users weary of counterfeits and mislabeling in raw material trade. Chain-of-custody matters. Every drum traces back to a unique lot, tied into our ERP system and documented in shipment logs. A long history of direct sourcing reduces chain complexity, slashing the risk of “lost in translation”-style mistakes common in third-party traded material.
Each label and packaging seal carries our factory lot number and data. Our technical and compliance officers can quickly trace complaints — or accolades — back down the line, offering certainty to regulators and customer QA teams alike. Keeping our production in-house shuts off narrative doubts that arise when suppliers can’t explain their own product’s test results or origin.
We share these details because sourcing reliable 4-(Dimethylamino)butanoic acid hydrochloride rarely comes down to a product number or a single assay value. In real operations, the difference between “good enough” and “keeps you out of trouble” gains meaning as batches scale and timelines compress. Experience making — and, at times, remaking — this compound in the real world sharpens our view of what matters most for both scientists and production managers on the other end of the supply chain.
Every decision, from raw materials to packaging, reflects learning from close interaction with teams that use this product at every scale. Our aim is long-term consistency, supported by operational transparency and ongoing process improvement, so every user finds reliable results batch after batch.