HS Code |
472626 |
| Chemical Name | 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole |
| Synonyms | Bifunctional Fluorescent Reagent, SBD-Cl |
| Molecular Formula | C6H2Cl2N2O3S |
| Molar Mass | 269.07 g/mol |
| Cas Number | 2979-19-3 |
| Appearance | Light yellow to beige crystalline powder |
| Solubility | Soluble in organic solvents such as DMSO and DMF |
| Melting Point | 184-187 °C |
| Fluorescence | Strong blue fluorescence under UV light |
| Application | Used as a derivatizing agent for amino acids and amines |
| Storage Conditions | Store at 2-8°C, protected from light and moisture |
| Purity | Typically ≥98% (HPLC) |
| Sensitivity | Highly sensitive reagent for fluorescence detection |
As an accredited 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole [Bifunctional Fluorescent Reagent] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The 1g Sigma-Aldrich bottle is amber glass with a tamper-evident cap, labeled with reagent details, hazard warnings, and grade. |
| Shipping | **Shipping Description:** 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole (Bifunctional Fluorescent Reagent) is shipped in tightly sealed containers with appropriate hazard labeling. Transport follows regulations for corrosive and environmentally hazardous substances. Temperature control and secondary containment may be used to prevent moisture and light exposure. Shipping documents comply with IATA, DOT, or ADR guidelines. |
| Storage | 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole should be stored in a tightly sealed container, protected from light and moisture, in a cool, dry, and well-ventilated area. Keep away from incompatible materials such as strong bases, acids, and oxidizing agents. Store at ambient temperature unless otherwise specified by the manufacturer. Ensure proper labeling and restrict access to authorized personnel only. |
Competitive 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole [Bifunctional Fluorescent Reagent] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Our plant handles the production of 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole, commonly referenced among researchers and process designers as an efficient bifunctional fluorescent reagent. This particular compound has proved valuable in both academic and industrial laboratories for the tagging and analysis of amines, thiols, and other nucleophilic moieties. The work behind this reagent relies strongly on organic chemistry fundamentals and a focus on adaptability during real-world synthesis and analytical applications.
Customers will find our batches consistently meet a purity of at least 99 percent, verified by HPLC and NMR. The solid appears as a light-yellow crystalline powder, with batch uniformity maintained through in-house purification and particle size control. Our packaging prevents degradation from light and moisture, preserving the reactive sulfonyl chloride and chloro functionalities critical for downstream modifications. The structure itself—the 2,1,3-benzoxadiazole core functionalized at positions 4 and 7—offers unique selectivity in conjugation reactions, particularly where minimal side reactions and high labeling efficiency are required. Molecular formula C6H2Cl2N2O3S and a typical molecular weight of roughly 265.1 g/mol provide a straightforward baseline for those in method development or process scale-up.
From our experience supporting R&D projects and manufacturing scale runs, several capabilities stand out. One key feature of this reagent is its innate fluorescence, which researchers leverage to track derivatized molecules directly through HPLC, TLC, or capillary electrophoresis. Chemists preparing biological samples for quantitative analysis or detection—proteins, peptides, or small molecules with exposed amines or thiols—find the specificity and reactivity of this reagent critical. For example, we have seen university researchers use it to selectively tag primary amines under mild conditions, avoiding unwanted cross-reactions with carboxylate or hydroxyl groups. This selectivity allows for more accurate, reproducible quantitation in biochemical assays and improves detection limits, particularly in complex matrices.
Production chemists and method developers value the robust nature of the reagent’s chemical interface. The chlorosulfonyl moiety acts as an activated sulfonyl chloride, engaging nucleophiles rapidly at moderate temperatures and neutral or lightly basic pH. Researchers optimizing conjugation protocols can achieve high yields without harsh reagents or extended heating, preserving the target compound’s structure and biocompatibility. Our facility’s consistency in controlling impurity profiles translates to more predictable and cleaner coupling reactions.
Comparing our 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole to traditional mono-functional benzofurazan-based labels, two aspects emerge: the dual functionalization and the derived physicochemical properties. Many earlier-generation benzoxadiazole reagents include either a sulfonyl chloride or a halogen in the electron-deficient ring, rarely both. By integrating both the chloro and chlorosulfonyl functionalities at strategic positions, this compound reacts with a broader spectrum of functional groups and permits sequential derivatization or orthogonal labeling strategies. We routinely see our customers using this feature to design stepwise conjugation schemes—an important tool in modern chemical biology.
Some reagents in the benzoxadiazole family produce weaker or more transient fluorescence, particularly under aqueous or slightly acidic conditions. Our manufacturing controls mitigate this issue by maximizing lot-to-lot consistency in chemical structure and avoiding fluorescent quenchers or trace metal contamination. End users report stronger, more stable signals, which become particularly valuable when applying fluorescence microscopy and flow cytometry, where sharp signal-to-noise ratios inform quantitative imaging or cell-sorting outcomes.
Synthesizing this compound requires careful handling of chlorosulfonyl chloride and establishing controlled conditions to add the chloro substituent without over-chlorination. As operators and process engineers, we have invested in closed-system synthesis lines and real-time monitoring—for example, in-line FTIR to confirm reaction completeness and mitigation of any unwanted by-product formation. During scale-up phases, customers have asked us about purity drift, but years of experience highlight that in-process sampling and rigorous reactor cleaning keep cross-contamination below detectable limits.
In the purification stages, we select solvent combinations that preserve the compound’s crystallinity and avoid polymorphism, which can complicate downstream dissolution or storage. QA staff double-check batch records, verifying both the starting material pedigree and final product identity using multi-dimensional NMR and tandem mass spectrometry. By focusing on these parameters, we bring a reagent to market that minimizes batch variability, a feature that end-users depend on for regulatory filings or publication-quality reproducibility.
Because of its strong electrophilicity and fluorescent output, this reagent draws interest from several scientific sectors. Analytical chemists use it primarily to label amino acids or peptides, then detect them at low concentrations post-separation. For example, high-throughput LC-MS workflows in proteomics rely on robust fluorescent reagents to tag analytes, especially when sample pools run into thousands per week and peak identification must remain unambiguous. Our customers’ feedback points to improvements in both detection limits and speed compared to less reactive or less stable alternatives.
In bioorthogonal labeling, where functional group selectivity must be assured even in living cells or unpurified tissue extracts, this benzoxadiazole’s chemical balance supports minimal off-target reactivity. Pharmaceutical process chemists have conducted automated high-throughput screens with this reagent, tagging small molecule libraries in situ without purifying each intermediate. Here, time savings and certainty in detection allow them to focus resources farther down the discovery funnel.
Fluorescence tagging methods have advanced sensitive biomolecule detection, particularly as instrumentation improved. The intrinsic brightness and stability of this compound’s emission spectrum decrease data acquisition time and reduce error during quantitative analysis. Laboratories running environmental, food, or clinical diagnostics benefit directly—less time on derivatization and column cleaning translates to higher daily sample throughput and more consistent results.
We have worked with analytical scientists troubleshooting interference from matrix effects—serum, plant extracts, or wastewater can challenge signal detection. Using our reagent, teams report smaller background peaks and clearer differentiation of target compounds. This reliability enables more straightforward validation with regulatory authorities like the FDA or EMA in preclinical dossiers or commercial batch-release documentation.
We package 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole in light-resistant, hermetically-sealed vessels, each with a unique lot code for traceability. Anyone who has experienced photodegradation knows the importance of reliable storage—there is little margin for error in analytical or preparative settings. Since trace moisture can hydrolyze the sulfonyl chloride group, we take extra care in the filling and sealing process, constantly monitoring environmental controls and lot stability through accelerated aging tests.
For users scaling from bench to pilot quantities, we offer technical advice tailored by prior experience with this chemistry: dry powder transfer protocols, air displacement pipetting of dissolved stocks, and best practices for reagent longevity after opening. This hands-on knowledge comes directly from our own lab teams, reflecting what works in the field rather than textbook recommendations alone.
Manufacturing halogenated and sulfonated aromatic compounds can involve challenging safety, waste, and regulatory considerations. Our facilities follow REACH, TSCA, and local environmental protocols to curb emissions, maintain worker safety, and manage residues. Chlorosulfonyl intermediates demand both chemical and physical containment, monitored via closed vent systems and redundant scrubbers. Through these steps, we reduce hazardous exposure not just in our own operations, but for logistics and warehousing partners downstream.
We prioritize transparency in providing customers with accurate SDS, shelf life data, and impurity analyses to simplify their compliance needs. As regulatory landscapes tighten worldwide, we proactively review safety and transport codes, updating shipping documentation to align with new GHS labeling requirements or customs declarations. This approach keeps projects on schedule and builds long-term trust with both academic and industrial users.
Some of our customers, especially principal investigators and analytical team leads, tell us about breakdowns with less robust fluorescent reagents—batch inconsistency, poor stability, or unexpected byproduct peaks can wreck weeks of method validation. We take these stories seriously, incorporating them into both product refinement and customer support. For example, complaints about off-color crystals or decreased signal led us to review supply chain purity and step up final product photography for each batch. Over several product generations, direct feedback has improved both reliability and user satisfaction.
Larger customers running automated workstations seek uninterrupted supply and minimal variability. Our production planning now includes rolling safety stocks and real-time inventory updates to meet fluctuating demand, especially during academic grant deadlines or pharma project fast-tracking. Frequent dialogue with users—technical queries, complaints, shared troubleshooting—encourages our own staff to think beyond the page of a spec sheet and focus on what truly makes a difference at the bench.
Challenges arise during derivatization—solubility in mixed aqueous-organic systems, compatibility with multiple substrates, or unexpected secondary labeling. We publish application notes drawn from in-house pilot runs as well as collaborations in external labs. Solvent recommendations, optimal reagent concentrations, wash protocols, and fluorescent quantification tips come from careful experiments and feedback cycles. This process leads to real-world improvements, not just theoretical ones.
For labs with green chemistry priorities, waste minimization plays an increasing role. The high reactivity and selectivity of the 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole scaffold means that reactions reach completion with smaller excess and less byproduct formation compared to alternatives. Downstream, this means less spent solvent, simpler workup, and less operator exposure to hazardous dust or volatiles.
We don’t just process and ship orders—we keep an eye on improving process reliability. Staff participate in Six Sigma and lean manufacturing audits to cut waste during both batch and continuous runs. Any deviations trigger root cause analysis, with corrective action documented and shared in our regular team meetings. By integrating these practices into daily operations, our customers enjoy less downtime and fewer unexpected results in their labs.
Monitoring long-term storage stability is another ongoing project. We run real-time and accelerated aging studies on each batch formulation, providing up-to-date expiration dating rooted in actual observed data. This transparency keeps customers confident about their shelf stock, reducing purchased overages or last-minute ordering headaches.
Fluorescent labeling demands more than just high reactivity. Researchers look for a reagent that fits their workflow, produces a clear and unmistakable signal, and can be trusted batch after batch. Our efforts in refining the process and staying attuned to laboratory challenges mean users encounter fewer headaches—no surprises from contaminants, batch variability, or storage-induced decay.
Our in-house teams stay connected to the needs of both university and enterprise-scale partners. Whether it's planning for bulk release in kilo runs or packaging small vials for method development, we apply firsthand knowledge about what creates hassle-free, reliable research progress. This approach grows out of direct experience with laboratory setbacks, regrouping until the outcome supports the demands of modern science, not just theoretical requirements.
The journey from raw materials to a high-purity fluorescent reagent involves hundreds of small, careful choices—each informed by people working on real production lines and with real analytical equipment. We know users want dependability, not just a promising molecule. By linking our manufacturing know-how, application support, and responsive logistics to the real-world needs of researchers, we keep elevating standards for what a working fluorescent tag should deliver.
As science continues to push for more sensitive assays, sustainable chemistry, and digital integration in laboratory operations, we are committed to having both the chemistry and the practical experience needed to help users succeed. Our ongoing improvements draw from a history of process learning and a commitment to solving application problems—whether optimizing a reaction for high throughput or troubleshooting a tough matrix analysis. 4-Chloro-7-chlorosulfonyl-2,1,3-benzoxadiazole represents not only a catalog offering, but a culmination of collaborative problem-solving among chemists who understand what matters at every stage of the scientific process.