|
HS Code |
352036 |
| Cas Number | 24887-22-3 |
| Molecular Formula | C5H5BrS |
| Molecular Weight | 177.06 |
| Appearance | Colorless to pale yellow liquid |
| Boiling Point | 198-200°C |
| Melting Point | -21°C |
| Density | 1.615 g/cm³ |
| Purity | Typically ≥98% |
| Refractive Index | 1.570 |
| Flash Point | 83°C |
| Smiles | CC1=CC(=CS1)Br |
| Solubility | Slightly soluble in water, soluble in organic solvents |
As an accredited 4-Bromo-2-methylthiophene factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 4-Bromo-2-methylthiophene (25g) is supplied in a sealed amber glass bottle with a screw cap, labeled with hazard warnings. |
| Shipping | 4-Bromo-2-methylthiophene is shipped in tightly sealed containers, protected from light and moisture, and labeled according to hazardous chemical regulations. It is handled as a flammable liquid and may require ground transport with appropriate hazardous material documentation, following all local, national, and international shipping regulations. Delivery is typically by registered chemical carriers. |
| Storage | 4-Bromo-2-methylthiophene should be stored in a cool, dry, and well-ventilated area, away from sources of ignition and incompatible substances such as strong oxidizers. Keep the container tightly closed and protected from light. Store at room temperature, following manufacturer recommendations and local regulations for flammable organic compounds. Use appropriate chemical-resistant containers to prevent leaks and contamination. |
Competitive 4-Bromo-2-methylthiophene prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
4-Bromo-2-methylthiophene, known to chemists by its CAS number 28404-80-6, doesn’t come together on its own. In our experience operating reactors and running fractional distillations, every batch tells its own story. Operators gauge progress from how the reaction mixture behaves, not just from meter readings; they listen for subtle changes in reflux, monitor temperature slopes, eyeball color transitions—little things that signal whether a process stays on track or drifts sideways. Our hands-on skills and the years we've spent resolving batch-to-batch inconsistencies bring certainty to essential properties: clear, colorless to pale yellow liquid, recognizable by its distinctive odor and its crisp, fast-moving peak in the chromatogram.
It’s tempting to reduce 4-Bromo-2-methylthiophene to a single assay number. In actual practice, purity goes beyond the GC percentage. We spot-check for residual halides, trace sulfides, and even sharp alkali odors after workup because they tell us what’s really in the drum. We check refractive index and density not out of habit, but because we have learned that off-the-chart numbers—even a small shift—can tip off wider process deviations. Over years turning out this thiophene, we’ve seen that small differences in raw materials, wash water, and even operator timing can leave detectable marks on product performance in later synthetic steps, especially for users in the pharmaceutical or agrochemical fields.
Almost every shipment winds up in a synthesis, often as a starting material for advanced heterocyclic intermediates. Process chemists, particularly those developing active pharmaceutical ingredients, depend on the clean reactivity of our bromothiophene. Its single bromo group allows straightforward cross-coupling reactions, while the methyl group steers regioselectivity during lithiation or Grignard reactions. Customers working on custom molecules have reached out after trial runs to describe minor color shifts, downstream yields, or unexpected side reactions. These calls don’t get bounced around—they go straight to the folks running the plant. That feedback has prompted us to fine-tune drying steps, change filtration media, and even optimize quench temperatures. These adjustments aren't marketing slogans; they're actions we take to see our product behave exactly as it should at your bench.
The shelves list a dozen brominated thiophenes. Some have bulkier substitutions, others a bromo group on a different carbon. Chemically, that changes everything—reactivity, solubility, volatility, and even odor. We don’t believe in generic output. Our 4-Bromo-2-methylthiophene carries a tight specification on isomer content, so nothing unusual drifts into subsequent steps. We worked with both kilo labs and multi-ton plants to listen to what mattered most: lot-to-lot consistency in color, rapid dissolution in standard solvents, and minimal cross-contamination from prior runs. Process tweaks didn't appear overnight; lab failures taught us the hard way about carryover risks from dirty flasks or lines left idle too long. Proper cleaning and equipment sequencing have earned us trust from repeat buyers who care less about the words on the certificate and more about whether their process behaves as expected batch after batch.
In theory, this compound’s synthesis looks straightforward. You start with 2-methylthiophene, run a bromination, then carefully isolate and purify. Our early years saw our own share of missteps—over-bromination, low yields from slow extractions, or darkening during solvent removal. These failures left valuable lessons. Modern production benefits from automated metering and online analysis, but even now, we keep a close eye on how long starting material sits in storage, the exact concentration of brominating agent, and the presence or absence of trace metal impurities from our processing equipment. Mistakes aren’t buried—they become training points. Batch data from off-spec material, yield tables on every run, and operator notes sit right next to fancy chromatograms. These real-world records form our operational backbone and let us deliver material that matches published analytical data time after time.
We can't manufacture in a vacuum. Regulations on brominated aromatics have tightened in recent years due to both worker safety and environmental impact. We engineer exhaust scrubbers and maintain detailed logs on waste streams. Operators wear respirators and gloves not because someone outside told us to, but because we’ve experienced splashes and accidental inhalations, so we know fi rsthand what’s at stake. Quality doesn’t come just from a tidy batch coming out of the reactor; it comes from not cutting corners with waste disposal, by running every vent stream through appropriate treatment, and by making sure the people running the processes know what’s safe and what isn’t. Audits and compliance checks aren’t dreaded—they keep us honest and keep us learning. We continually upgrade our facilities to address evolving safety standards, from double-sealed pumps to leak-proof transfer systems.
For every application, whether pharma, electronics, or specialty materials, reliability counts for more than any claim. Buyers, especially those supplying demanding markets, ask about crystallization behavior, storage temperature, and stability on the shelf. These questions aren’t handled by a phone bank—they reach the chemists who compound each batch and who have spent time debugging labels, packaging, and drum closures. A reliable intermediate speeds up process development and eliminates unexpected downtime. Over time, synthetic chemists have told us about successful Suzuki or Negishi couplings, while others pushed the product in less obvious directions—testing its limits in photonic materials, or in the back-end steps of complex dye synthesis. Direct feedback forms loops that help us adjust and improve, ensuring material actually meets target properties under real processing conditions.
Differences between halogenated thiophenes may not seem dramatic until synthesis actually starts. The position of the bromo and methyl groups changes how the compound behaves—how it dissolves, how it responds under basic or acidic conditions, even how it interacts with catalysts in palladium-catalyzed couplings. Subtle impurities, isomer content, and residual moisture impact crystallization and storage stability. Overheating can drive rapid color changes and, in some cases, unpredictable decomposition, so we pack and ship to preserve quality. We scrutinize isomer ratios in our analytical labs and make sure water content stays minimal, since excess water often means side reactions and inconsistent yields downstream. Chemists who’ve used similar compounds with bromo groups on other positions often report different reactivity, lower selectivity, or difficulties in purification. We understand these challenges because we’ve run these experiments ourselves, troubleshooting protocols in our own R&D departments.
Customers sometimes call us after ordering because they spot something unusual: a faintly yellow hue, a hint of odor, or a packing label that seems unclear. Rather than just delivering product and forgetting about it, we assign field scientists to follow up, look into analytical data, and even run quick tests in our pilot lab. These small, prompt actions help customers recognize that someone actually listens and works from experience. By sharing yield data, handling tips, and even warning about temperature sensitivity, we partner in every step from scale-up to pilot plant runs. The result is more than just a lot number—it’s knowing exactly what you have, why it behaves the way it does, and what we can do to keep it working for you.
Analytical certificates might appear routine on their own, but ours are built from actual in-process samples, cross-checked using multiple techniques. We run GC and HPLC for purity, but also include NMR when requested because subtle peaks often hide trace isomers or impurities that standard grade specifications miss. Routine sampling along the production line lets us respond to changes in feedstock and to preempt issues before they become batch-scale losses. Repeated internal checks ensure reliability across larger campaigns, so large orders see the same compositional profile as the kilo sample a customer first approved. Analytical chemists in our lab take pride in matching published spectra for key signals and always explain anything unusual, from minor baseline drift to outlying retention times.
Many chemical manufacturers recite standard storage guidelines, but our advice comes from repeated handling. We store this thiophene derivative under inert gas and away from sources of heat, since it reacts to oxygen over time and darkens if left exposed. In the summer, excess warehouse heat can increase volatility and cause pressure build-up; we’ve addressed this with temperature controls and proper drum venting. Some packaging configurations performed better than others—poly liner and PTFE-sealed caps maintain the liquid better than cheaper alternatives. We’ve replaced older containers with more robust packaging based on actual rejects and returned drums. Every shift checks for leaks, swelling, or pressure before loading for transport, because ignoring these steps risks damaging a valuable batch and wastes everyone’s effort.
Each customer, large or small, engages with us for the same underlying reason: confidence that what leaves our site matches the needs of their reaction and development work. Over the years, we’ve tested alternatives, switched raw material suppliers, and even rebuilt key parts of our process equipment to hold tighter tolerances and eliminate contamination. Product is only as valuable as the outcomes it enables. We talk with partners about their own process headaches, swapping tips not limited to technical data sheets, but born from the reality of troubleshooting fouled reactors or scaling tricky reactions. Teams at our site compare notes after every full-scale production run, integrating insights from the shop floor, lab data, and customer feedback. Transparent communication with end-users closes the loop and keeps our own standards rising.
Few manufacturers stand still; we’re always learning. Every run, every finished drum, and every piece of feedback join a larger story. We work on incremental changes that raise both yield and user satisfaction, such as fine-tuning purification columns or testing alternative brominating agents that generate less waste. Investments in process automation and analytics pay off not simply by tracking numbers, but by freeing our teams to focus on the tougher questions—what input variable matters most, how can we reduce energy or water use, and what benefits do customers notice first? Lessons learned from our own failures—unclean condensers, storage temperature spikes, rush jobs that didn’t meet target spec—form the bedrock for our continuous improvement mindset. Everyone on our team, from raw materials handlers to analytical chemists, shapes the resulting product.
Real value arrives in the impact on users’ processes. Synthesis of advanced intermediates, API precursors, OLED materials, or agricultural candidates often depends on high-purity starting materials. Our customers in scale-up teams run iterative experiments and demand repeatable behavior, especially during high-stakes registration batches. We pay attention to how small residuals or unexpected byproducts cascade through their processes, often making or breaking entire research efforts. Partnerships with leading R&D labs keep us alert to both changing technical needs and potential regulatory shifts, so we can adapt production accordingly. Actual use cases shared by long-term partners drive our own innovation in both product and process.
Day in and day out, we transfer our hands-on production wisdom into every bottle, drum, and container of 4-Bromo-2-methylthiophene. Our experience doesn’t just come from manuals or published articles—it’s earned from real runs, troubleshooting hiccups, and continuous back-and-forth with users pushing boundaries. Every small choice—from how we source raw materials, operate the plant, analyze each lot, or respond to unexpected challenges—builds cumulative trust. Buyers care less about labels and more about whether our product works with the precision their science demands. That’s the sort of reliability only a committed manufacturer, grounded in practical work, brings to the table.