HS Code |
375565 |
| Product Name | 3-Morpholinopropanesulfonic Acid |
| Common Abbreviation | MOPS |
| Molecular Formula | C7H15NO4S |
| Molecular Weight | 209.27 g/mol |
| Cas Number | 1132-61-2 |
| Appearance | White crystalline powder |
| Pka At 25c | 7.20 |
| Buffer Range | 6.5 – 7.9 |
| Solubility In Water | Freely soluble |
| Melting Point | 273-280 °C (dec.) |
| Storage Conditions | Store at room temperature, keep container tightly closed |
| Usage | Buffering agent in biological and biochemical research |
| Synonyms | MOPS, 3-(N-Morpholino)propanesulfonic acid |
| Odor | Odorless |
| Grade | Research/Biological grade |
As an accredited 3-Morpholinopropanesulfonic Acid [Good's buffer component for biological research] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | White, high-density polyethylene bottle, 500 grams, screw cap, tamper-evident seal, labeled with Sigma-Aldrich branding and safety data. |
| Shipping | 3-Morpholinopropanesulfonic Acid (Good’s buffer component) from Sigma-Aldrich/Merck/TCI is shipped in tightly sealed containers to maintain purity and prevent contamination. Standard shipping complies with chemical safety regulations, often via ground or air freight, with appropriate labeling and documentation, suitable for laboratory and research use. |
| Storage | 3-Morpholinopropanesulfonic Acid (Good's buffer, Sigma Aldrich/Merck/TCI grade) should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area away from incompatible substances. Protect it from moisture and direct sunlight. Store at room temperature (15–25°C) and ensure clear labeling. Always follow manufacturer’s specific storage guidelines and safety data sheet instructions for optimal stability and safety. |
Competitive 3-Morpholinopropanesulfonic Acid [Good's buffer component for biological research] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
We produce 3-Morpholinopropanesulfonic Acid (MOPS) from the ground up, using carefully selected raw materials and rigorous synthetic methods that enable the high purity required for use in sensitive biological research. Our work as a manufacturer stays closely tied to the needs of researchers who rely on strength, stability, and reliability for biological buffers. Many scientists trust MOPS for its unique buffering performance, especially in applications where pH must remain sharply controlled without introducing unwanted variables into the system.
The chemical structure of MOPS, including its morpholine ring and sulfonic acid moiety, means it falls into the Good’s Buffers family. These buffers were originally designed to minimize interference in biochemical experimentation. We pay specific attention to maintaining low levels of contaminants such as heavy metals and organic byproducts, based on conversations with lab users who have seen how even minor impurities can result in inconsistent or unreliable data. Experience from our manufacturing lab shows that degradation in quality starts to influence both DNA/RNA stability studies and enzyme assays, so for every batch we run a comprehensive check of purity and functional tests across relevant pH ranges.
For customers looking for specific batch characteristics, our MOPS comes in several particle sizes and grades. Standard production yields a white crystalline powder with a molecular weight of 209.25 g/mol. A pKa around 7.2 at 25°C places the buffer squarely in the range where most biological reactions operate. Control over solubility in water and negligible absorption in UV-visible ranges reflect requests from clients needing faithful reproduction in spectroscopic or kinetic assays.
We work directly with research groups who have described how enzyme activity can vary with trace ionic contamination, so every lot undergoes ionic strength and conductivity testing using standardized protocols. The drying steps in our facility help ensure consistent moisture levels, which reduces weight variation per volumetric aliquot, helping automate workflows in robotic or high-throughput laboratory setups. Our long-running clients in the pharmaceutical sector frequently request information about residual solvents or endotoxins, so we audit these metrics per batch as part of our routine control.
Customization remains an integral part of manufacturing. Some clients working in pharmacology request fine-powdered MOPS to speed up dissolution during high-volume screening. Others require coarse granules, reducing airborne dust risks in open-air weighing rooms. Years of collaboration with universities have also exposed the preference for different packaging sizes, so we produce lots in quantities from grams up to multi-kilogram drums. We ship under low-humidity and light-blocking conditions, knowing how much hydrolysis or photodegradation can jeopardize long-term buffer performance.
Working in the lab, we see firsthand how experimental needs differ. Compared with other Good’s buffers such as MES, HEPES, or PIPES, MOPS finds particular favor for RNA work because of its minimal reactivity with amino acids and nucleic acids. In our support lines, we often listen to users discuss problems with competing buffers—HEPES introduces additional background fluorescence in some enzyme-linked assays, and PIPES suffers from narrower effective pH range.
The sulfonic acid group in MOPS reduces its tendency to cross-react with transition metal ions, so it’s less likely to interfere in metalloprotein or enzyme kinetic studies. Direct feedback from proteomics researchers steered our process improvement projects so that trace metal analysis by ICP-MS became a staple in our QC. MES, for example, starts to acidify more rapidly when samples stay open for long periods; MOPS resists this acidification under ambient atmosphere, which makes it a favorite for long-running electrophoresis or chromogenic assays.
As a manufacturer, we’ve learned how undesirable buffer degradation leads to costly repeat experiments. Instances of intermittent assay drift could often be traced back to poor-quality buffers that leached unidentified impurities. With MOPS, we find that its chemical stability in aqueous solution at room temperature, and resistance to microbial growth, enables storage and use over extended timeframes. Researchers have confirmed that protein aggregation events are far less common in MOPS solutions compared to weaker buffers, reducing false positives in protein stabilization studies.
It’s common for new customers to contact us seeking help with buffer selection. Some users are transitioning from Tris, a widely used buffer with a broad pH range but limited temperature stability. Tris buffer pH shifts noticeably with even a few degrees’ temperature change—something that’s not always apparent until late in development. Direct comparison in our pilot lab found that MOPS maintains a steady pH during temperature cycling from 15 to 40°C. This kind of temperature stability frequently matters in automated cell culture, fermentation, or live-cell imaging suites where environment swings are routine.
Demands for high-throughput screening led to numerous questions about buffer-to-plate compatibility. We validated our MOPS against polycarbonate and high-density polypropylene microplates, where chemical inertness eliminates undesired plate interactions. Edge effects and evaporation-induced pH drift decrease sharply with MOPS when compared to borate- or carbonate-based systems. Editorials from core facility staff point out that this reduced edge variability accelerates method validation, while unwanted fluorescent artifacts stay low thanks to the buffer’s negligible UV-Vis absorption near 260-280 nm.
From the manufacturer’s side, scaling up for industrial clients uncovers batch-to-batch consistency issues that may not affect small academic lots. We maintain process control from the earliest chemical charging through the final sieving and packing stage. Each kilo of MOPS we ship carries traceability down to individual reactor charges. Sometimes, research customers express concern about "unknowns"—we publish our analytical traces directly alongside shipment documentation, including any observed side products below the reporting threshold.
Scientists in antibody engineering appreciate how MOPS stays virtually inert during conjugation steps. We’ve supported teams who moved their protocols from phosphate buffers to MOPS after observing unwanted precipitation when metal chelates were introduced. The switch cut down on inconsistent background signals. Our process expertise—especially in fine tuning ionic strength and light-blocking packaging—came directly from solving these real-world issues.
Clients working in genomics testing services also require buffer-grade sureness. We conduct side-by-side stability tests against competitive MOPS samples sourced from traders or resellers. Inferior grades, often with slight discoloration or faint odors, produce baseline shifts or increased PCR cycle times. We optimize our purification routes to keep colored contaminants out, using in-line UV-Vis monitoring and clean-in-place reactor protocols that minimize residual organic fouling.
Direct chemical synthesis and the responsibility that brings means we address both worker and downstream safety head-on. Our production system is ventilated and includes robust dust collection to reduce on-site exposure. With growing focus on sustainability, we modified our process to recover and recycle solvents used in crystallization stages, lowering both raw material demand and waste. Regional regulations around chemical manufacture evolve; our facility incorporates rigorous wastewater treatment and all spent reagents undergo neutralization, reviewed by internal teams before any off-site disposal.
Transportation and storage risks factor into our packaging approach. End users have shared stories of buffer caking or clumping because of poorly controlled humidity levels in shipping containers. We introduced moisture-sealed drum liners and silica gel buffers to keep products dry, and we log storage conditions using temperature and humidity recorders for key shipments. Such measures, while never flashy, have earned us repeat custom from clients who recall past disruptions caused by substandard buffer handling.
Longstanding partnerships with bio-research consortia taught us to watch for product counterfeiting and adulteration. Direct engagement with customers helped us develop batch-marked hologram seals and documented certificates of origin, along with secure chain-of-custody transport for sensitive lots. This extra layer of assurance guards against substitution—a risk that can derail experimental timelines and research credibility.
Acting as more than a mere supplier, our staff often fields questions from researchers dealing with day-to-day operational challenges. Whether users encounter unexpected buffer precipitation or microbe contamination during storage, our chemists draw directly on manufacturing floor experience to troubleshoot and recommend adjustments. For example, some clients experience cloudiness in high-concentration MOPS solutions. Tests in our own lab revealed the main factor relates to rapid temperature drop upon buffer preparation, so controlled mixing and gradual temperature equilibration greatly reduce this issue.
Implementation in bioprocess development calls for more than just purity. Our technical specialists collaborate with upstream process scientists to fine-tune buffer concentrations, helping manage osmotic balance and maintain cell viability even during high-density fermentation. Adjustments in buffer concentration or supplementing with chelators occasionally address metal-catalyzed side reactions, with full technical references provided for every solution suggested. We frequently share our latest dataset compilations to keep labs informed about how our MOPS compares against broader Good’s Buffer standards published in academic literature.
Scaling experimentation from benchtop to pilot plant often challenges even experienced users. We welcome pilot-lot orders, sharing our insights from process validation runs that highlight filter compatibility, required dissolution times, and storage stability under industrial conditions. Input from trusted research institutions helped us set up real-time stability studies and extended stress-testing, which now underpins our expiration dating and recommended storage instructions.
Client feedback forms a key plank in our ongoing process improvements. Specific customer complaints about particle size variation or delayed shipments pushed us to modernize our milling and packing infrastructure. With each improvement—faster sieving cycles, automated weight checks, and faster drying times—we’ve increased both turnaround speed and lot-to-lot reproducibility. Product comparisons against legacy buffer stocks, conducted in our in-house QA labs, regularly reveal drifting color and solubility in non-optimized batches. We use these direct performance comparisons as education tools for both our team and our customers’ research staff.
As demand surges in the RNA therapeutics and gene editing sectors, more clients seek higher assurance about buffer origin and integrity. Our open-lab events, instrumentation tours, and transparent process documentation answer these needs. Instead of shielding process details, we actively publish batch-level data sheets and impurity profiles, knowing that research reproducibility only strengthens when users are empowered with in-depth information about every compound that touches their samples.
The shift toward remote and distributed work among research teams means that direct support matters more than ever. Our technical consultants provide real-world troubleshooting, often leveraging insights from earlier field failures and successful resolutions. This culture of learning and adaptation has kept our standards improving as fast as our research clients' needs change.
Within the field of biological buffer manufacturing, progress comes from continuous learning and adaptation. Recent trends—including mass expansion of translational research labs and fast-cycling biotech startup projects—call for greater flexibility around lot sizes, packaging, and technical documentation. As research scale increases, the demand for low-endotoxin, high-purity buffer stocks becomes ever sharper. Our ongoing upgrades to purification, packaging, and quality tracking aim to answer this rising bar for consistency.
Our engagement with global research networks keeps us abreast of the latest applications in next-generation sequencing, high-throughput drug screening, and advanced cell imaging. Each new challenge reveals blind spots—how packaging affects shelf life, how subtle impurity drift undermines week-long kinetic assays, how UV transparency supports cutting-edge detection platforms. Responding to these immediate user concerns shapes every upgrade and process change undertaken.
The end goal is practical and clear: to equip scientists and research professionals with buffer stocks that never compromise their results. With more than two decades in direct chemical manufacture, we’ve seen the cycle repeat—every buffer failure leads to wasted resources, missed deadlines, and lost data. By anchoring our manufacturing choices in direct customer dialogue, analytical transparency, and a hands-on approach to problem-solving, we help safeguard the quality and consistency of biological research in every lab where our MOPS buffer is put to work.