HS Code |
113149 |
| Product Name | 3,3',5,5'-Tetramethylbenzidine Dihydrochloride |
| Cas Number | 54827-17-7 |
| Molecular Formula | C16H20Cl2N2 |
| Molecular Weight | 311.25 g/mol |
| Synonyms | TMB dihydrochloride |
| Appearance | White to off-white crystalline powder |
| Solubility | Soluble in water and DMSO |
| Purity | ≥98% |
| Melting Point | 168-173 °C (dec.) |
| Storage Temperature | 2-8°C |
| Lambda Max | 652 nm (in presence of peroxidase and H2O2) |
| Hazard Class | Irritant |
As an accredited 3,3',5,5'-Tetramethylbenzidine Dihydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Brown glass bottle containing 25g of 3,3',5,5'-Tetramethylbenzidine Dihydrochloride, labeled with Sigma-Aldrich branding and safety information. |
| Shipping | 3,3',5,5'-Tetramethylbenzidine Dihydrochloride from Sigma Aldrich/Merck/TCI Chemical is shipped in tightly sealed, chemical-resistant containers. Packaging complies with international regulations for hazardous materials. Shipments are protected from moisture and light, labeled with safety and handling instructions, and accompanied by a Material Safety Data Sheet (MSDS) for secure transit and recipient safety. |
| Storage | 3,3',5,5'-Tetramethylbenzidine Dihydrochloride (TMB, Sigma Aldrich/Merck/TCI) should be stored in a tightly sealed container, protected from light and moisture, at 2–8°C (refrigerated). Keep away from incompatible substances and strong oxidizers. Store in a dry, well-ventilated area, and handle under subdued light to prevent degradation. Always follow supplier and local safety guidelines. |
Competitive 3,3',5,5'-Tetramethylbenzidine Dihydrochloride prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Production floors in chemical manufacturing teach us to look beyond textbook descriptions. For us, 3,3',5,5'-Tetramethylbenzidine Dihydrochloride, commonly called TMB dihydrochloride, stands out for its significance in biochemical and clinical diagnostics. Diagnostics labs today require high-sensitivity reagents that deliver results with clarity, speed, and reliability, without confusing the process for technicians. Our daily routines focus on turning raw intermediates into a pure, reactive salt that fits those needs, shaped by years of handling organic peroxides and colorimetric substrates.
TMB dihydrochloride doesn’t just emerge from a catalog; it comes from precise batch reactions, controlled crystal growth, and thorough quality controls in our facilities. We optimize each batch for purity, keeping the lot-to-lot difference narrow. Unlike TMB free base, the dihydrochloride salt arrives as a fine, white-to-off-white crystalline powder, less sensitive to air and moisture mishaps during storage or weighing. Shelf-life questions rarely haunt users because, under dry, cool conditions, the material proves itself robust, reducing waste and restarts in both research and diagnostic production lines.
Standard packaging starts at 25-gram quantities, with scale reaching kilograms. From late-stage process checks to the final container, we pay attention to residual solvents, chloride content, and even the trace metal levels. Customers from high-throughput diagnostic kit manufacturers to small-scale academic researchers frequently ask about our analytical specification, and we show data—often outpacing typical thresholds for heavy metals, residue, and purity.
In enzyme immunoassays, every wrong move in the substrate stage can upend an entire plate of samples. TMB dihydrochloride, when dissolved in an appropriate buffer, acts as a chromogenic substrate for horseradish peroxidase (HRP). This is not just a technical checkbox; it is a real-world improvement for ELISA operators who value a crisp, blue color-developing in wells instead of streaks, precipitates, or ambiguous backgrounds. We’ve handled plenty of customer calls from teams who needed to push their lower detection limit—by squeezing every bit of consistency from their substrate reactions.
Unlike other peroxidase substrates like o-phenylenediamine (OPD) or ABTS, TMB dihydrochloride produces a soluble, bright blue product under HRP catalysis, with rapid conversion and minimal interference from sample proteins or common preservatives. The two-electron oxidation pathway creates a blue charge-transfer complex, which, following acidification, shifts into a stable yellow derivative. Readers relying on microplate spectrophotometry see sharp increases in absorbance at both 370 nm and 652 nm without troublesome precipitates or signal drifts, reducing retesting rates that drain staff time and budgets.
The same attribute makes the substrate safer in terms of handling. TMB lacks the carcinogenic risk associated with OPD, simplifying lab safety management and compliance reviews. And, since the dihydrochloride reacts cleanly and has low background at neutral pH, diagnostic lines enjoy higher throughput with fewer false positives or negatives.
Production teams working with both the free base and salt forms of TMB soon discover several practical differences. The dihydrochloride salt resists oxidation during handling. The crystalline material pours freely and withstands humidity changes in most climates, where free base TMB can sometimes clump or degrade if exposed, leading to inconsistent assay performance. Our technical staff have seen this firsthand—labs running morning and afternoon plates see sharper, more reliable signals from the salt.
Some customers ask about differences in solubility and color development rates between free base TMB and the salt form. Years of batch testing show that dihydrochloride dissolves more efficiently in common assay buffers and produces a more uniform substrate solution. This reduction in “hot spots” or undissolved granules helps minimize false signals on plates and helps QC managers who need stringent batch controls across global facilities.
Nearly every bioanalytical manufacturer faces the challenge of keeping workflows safe, especially when producing thousands of substrate-containing microplates daily. The dihydrochloride salt is less hazardous than nitro-based peroxidase substrates, which means easier storage, less regulatory difficulty, and fewer accidental exposures for both operators and maintenance teams.
From start to finish, we operate a controlled process. Raw material qualification, reaction monitoring, solid-liquid separation, and multiple washing steps happen in real time with every batch. Our people in process development have learned that even small deviations in washing or crystallization times show up fast during customer validation runs. We feed actual batch data—chloride titrations, melting point verification, trace impurity screens—straight into our shipping documents.
We don’t hide behind broad spec ranges or unverified claims. When customers ask for batch records, we provide them. Analytical data align with industry-standard methods, supplemented with in-house spectroscopic and chromatographic identification for peace of mind. End users in regulated industries, from diagnostics to environmental testing, tell us they value these data because their auditors do too.
Over time, our experienced staff has honed a sixth sense about yield reliability. If a batch of TMB salt emerges from crystallization outside our visual standard, or if the parent TMB has color or odor shifts, we stop and investigate instead of passing it through. We see the difference in fewer customer complaints and increased customer retention. Our own internal QC pass rates have improved over several years by remedying supply chain issues early in the synthesis, rather than later during repackaging or shipping.
Chemical manufacturers who actually test their own product safety data understand the value of straightforward guidance. Simple measures—keeping TMB dihydrochloride tightly closed and away from acidic mists or base fumes—preserve its functional shelf life. Lab teams appreciate a crystalline, well-drained product that scoops without sticking to spatulas or bottle necks. This functionality comes from our moisture-control protocols and packaging options, not luck.
Waste management with TMB salts is also easier to handle than many competitors in the substrate sector. Unlike OPD and some other aromatic amine derivatives, which often need more thorough hazardous-waste protocols, the TMB dihydrochloride waste (once used in diagnostic testing at microgram scales) typically fits local aqueous waste rules with straightforward neutralization and dilution.
From a process design standpoint, shelf-life extension means less product loss during distribution. Facilities operating in warm or humid regions want a product that withstands common storage deviations without forming colored degradation products. Our own long-term stability studies indicate over 95 percent activity retention for two years, far higher than many lyophilized or dichlorinated substrate analogs.
With every lot of TMB dihydrochloride, we come up against practical hurdles—raw material purity, scaling up consistent batches, and regulatory updates about residual metals and solvents. Sometimes, new environmental standards push us to tighten specifications even further. We develop solutions by working directly with chromatography and spectroscopy specialists, focusing on real impurity removal rather than relying on tradition or accepted practice. Collaborating with reagent kit manufacturers gives us perspective on color stability, pH drift, and shipping sensitivity that wouldn’t show up in a small-scale laboratory alone.
In one example, after several customer partners flagged frost-like clumping during a humid shipping season, we invested in redundant moisture-proof inner liners—an approach that stopped the issue cold and improved customer reviews. These efforts align with ongoing improvement rather than just following baseline GMP protocols.
Sustainability keeps rising in importance. Traditional nitrate-based peroxidase substrates raise environmental and handling risks. TMB dihydrochloride avoids these pitfalls. Reducing reliance on petrochemical process steps, recycling solvents when possible, and switching to lower-emission, closed reactor systems have all tangible impacts once scaled up across our plant. Operators in the plant see the benefits through lower maintenance downtime and fewer solvent spills.
Regulatory harmonization runs through product lines like ours. Diagnostic manufacturers in the US, Europe, and Asia look for certificates of analysis with more transparency and less marketing lingo. Our certificates reflect actual process deviations, plus impurity test results from major and minor synthetic byproducts. This transparency helps international partners clear customs, obtain registrations, and resolve customer claims faster.
Our staff includes chemists and technicians who have seen TMB’s evolution since its adoption in the late 1970s and early 1980s. Early variants of colorimetric HRP substrates carried too many safety risks and batch inconsistency issues. Over time, incremental improvements in production methods improved both the safety profile and reproducibility of results. The dihydrochloride form became a go-to for its reduced air sensitivity, ease of weighing, and ready solubility—benefits felt directly by assay developers and QC managers alike.
Some of our earliest customers used to call with questions about the effect of ambient light or mild oxidation on their stock substrate solutions. Our response—switching to dihydrochloride, improving container choice, and offering both amber-glass and moisture-resistant plastic options—reduced these incidents to near zero. Newer users entering the diagnostics market now rely on these standards as if they’re just common sense, but that foundation stands on decades of first-hand troubleshooting and continuous feedback.
Consistent raw material procurement reduces interruptions for all downstream customers. By tying our order volumes for TMB intermediates to forecast models informed by long-lead customer contracts, we avoid supply disruptions that can disrupt even the best-run diagnostic companies. Our purchasing teams formed direct relationships with major upstream chemical vendors, bypassing traders who sometimes introduce uncertainty or adulteration. This reduces lead times and builds mutual trust, which matters much more than chasing the lowest spot price.
Shipping logistics also impact product quality. Every extra day TMB spends in uncontrolled shipping environment—whether on a hot tarmac or in a delayed customs checkpoint—can increase clumping, yellowing, or performance loss. We have built processes around climate-controlled storage and shipping, tagging every batch with location and temperature, and tracking conditions until receipt by end users. Customers tell us they rarely find foreign particles or moisture-induced clumping in our shipments—a direct result of these supply chain investments.
The evolution of diagnostics, especially in public health crises, has shown the world the value of sensitive, reliable immunoassays. TMB dihydrochloride sits at the intersection of production chemistry and scalable health solutions. Our firsthand experience suggests that shortcutting on substrate quality or transparency can derail an entire diagnostic launch, whether for a malaria screen in Southeast Asia or a routine ELISA in an urban hospital lab.
We routinely engage with researchers developing new in vitro diagnostic devices and rapid test kits. Their feedback often guides small synthesis adjustments, whether tinkering with drying cycles, filtration pore sizes, or container materials. These micro-improvements add up. The odor, appearance, and solubility profiles of our finished TMB dihydrochloride tell users more than any certificate alone.
We respect patent holders and technology developers who originally brought TMB into widespread diagnostic use. Their efforts made possible the industrial scale and technical requirements that we now improve upon, using both classic bench chemistry and new digital process controls. Collaborative R&D efforts between manufacturers, diagnostics companies, and academic labs have led directly to substrate versions that fit automation, higher sensitivity, and lower environmental footprints—each positive shift built on iterative experience and honest problem-solving.
Manufacturing isn’t just a technical process. The teams responsible for each reactor batch, packaging run, and analytical report know that a single mistake could mean wasted research, misleading diagnostic data, or even missed patient outcomes. This sense of responsibility shapes our product. TMB dihydrochloride may look simple—just a bottle of white powder in a lab—but users relying on it deserve every ounce of attention to detail, from ingredient sourcing to finished packaging.
We welcome direct customer feedback, share both successes and setbacks in technical performance, and continually adapt our training for new regulations and process controls. Leaving room for honest feedback led us to fine-tune several batch-washing steps, which resulted in improved solubility and color shelf stability. Our line operators, chemists, and logistics staff each bring stories of batches rescued, process quirks discovered, and customer wins celebrated.
The market for peroxidase substrates will keep evolving as diagnostic devices shift to point-of-care or ultra-high-throughput settings. The push for greener chemistry, safer labs, and better automation will demand more from every bottle that leaves our plant. Instead of chasing the next marketing claim, our team leans on rigorous process data and lived experience in the field. Each decision—raw material checks, in-process controls, packaging tweaks—arises from thousands of hours spent troubleshooting and improving what could easily be overlooked.
For those in research, clinical diagnostics, or kit production, our TMB dihydrochloride product stands as the direct result of decades spent sweating the small stuff. The end product is a consistent, reliable, and safe substrate for HRP-based assays, trusted by developers and quality assurance teams, and continuously improved in response to real-world demands.