HS Code |
252629 |
| Chemical Name | 2,5-Diphenyloxazole |
| Synonyms | PPO |
| Molecular Formula | C15H11NO |
| Molecular Weight | 221.26 g/mol |
| Cas Number | 92-71-7 |
| Appearance | White to off-white crystalline powder |
| Purity | For scintillation spectrometry |
| Melting Point | 70-74 °C |
| Solubility | Soluble in ethanol, benzene, toluene |
| Boiling Point | 360 °C (decomposes) |
| Density | 1.15 g/cm³ |
| Flash Point | 181 °C |
| Storage Conditions | Store at room temperature, keep container tightly closed |
| Ec Number | 202-180-4 |
| Application | Organic scintillator in liquid scintillation counting |
As an accredited 2,5-Diphenyloxazole [for scintillation spectrometry] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sigma Aldrich 2,5-Diphenyloxazole (25g): Supplied in a sealed amber glass bottle with tamper-evident cap and detailed labeling for laboratory use. |
| Shipping | 2,5-Diphenyloxazole for scintillation spectrometry is shipped in sealed, chemical-resistant containers to ensure product integrity and prevent contamination. Packaging complies with safety regulations for hazardous materials. Shipping may require temperature control and appropriate labeling, with Material Safety Data Sheets (MSDS) included. Delivery is handled by certified couriers experienced in chemical transport. |
| Storage | 2,5-Diphenyloxazole [for scintillation spectrometry] should be stored in a tightly closed container, in a cool, dry, and well-ventilated area, away from direct sunlight and incompatible substances such as strong oxidizing agents. Keep the chemical at room temperature, and ensure proper labeling and secure storage to prevent contamination or accidental exposure. Use appropriate personal protective equipment when handling. |
Competitive 2,5-Diphenyloxazole [for scintillation spectrometry] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
At our facility, 2,5-Diphenyloxazole, often called PPO, plays a critical role in processes that demand accurate detection of ionizing radiation. For decades, we have been delivering this compound to laboratories and manufacturers who require reliable scintillation results. The typical model we offer supports high-precision scintillation spectrometry, serving as a primary fluorescent solute that excites readily in organic solvents. The years spent in scaling and refining our PPO synthesis have shown us which features matter in real-world settings: purity, actual solubility in organic media, and chemical stability under frequent use.
From firsthand experience, purity holds greater weight than many realize. Even trace metal contaminants or pointless interstitials in a batch will build noise in background readings. When a chemist sits down to run spectral analysis, spurious peaks cost time and material, not just reputation. Our synthesis routes focus on mopping up persistent by-products, distilling out oligomers, and targeting a purity threshold that consistently meets or exceeds the benchmark for emission clarity. Regular benchmarking in our labs has confirmed that PPO from tightly controlled lots outperforms more loosely sourced powders. Quality isn’t a matter of abstract assurance—it comes through in real counting accuracy.
The product we supply meets a specification of not less than 99.9% pure by standard HPLC analysis, with typical residual ash and transition metal content near instrument detection limits. These figures aren’t marketing bullet points—they help users run longer sequences, reduce statistical errors, and cut background drift.
Our teams and clients put PPO to work primarily in liquid scintillation cocktails, plastic scintillators, and thin-film dosimetric devices. In each form, the compound’s optical emission matches closely with the sensitivity window of photomultiplier tubes, squeezing more counts per decay event into measurable signals. Versatility shows up in the way PPO dissolves cleanly in solvents like toluene, xylene, and commercially available liquid scintillation cocktails. Our readings over the years have shown that users get the same sharp peaks and reproducibility whether using PPO for tritium detection in low-background research or swift survey measurements in field-deployable counters.
Lab technicians and field physicists notice the difference between PPO manufactured specifically for scintillation use and off-grade batches meant for less demanding fluorescence applications. Interfering background, peak spread, and recovery time all link back to the source and processing steps. High-quality PPO lowers required sample concentrations, which reduces the overall cost per assay and, sometimes, eliminates mineral oil loading to blunt quenching effects.
Any chemist can purchase PPO, but achieving clean results in spectrometry requires more than basic purity. We enforce a rigorous specification: water and volatiles below 0.05%, persistent organic impurities kept out by a two-step recrystallization, and “light-off” testing for afterglow to ensure fast decay profiles. Each batch moves from synthesis through dark storage until dispatch, with no light exposure that could trigger self-polymerization or yellowing.
We keep lot data transparent. Radiation counting facilities have verified batch-to-batch consistency by revalidating our finished PPO in their own systems. These feedback loops highlight issues that aren’t caught by a straightforward chemical assay. For example, photomultiplier dark counts attributed to trace carbonyls led us to upgrade purification steps years ago.
Standard laboratory PPO can fulfill roles in education or basic research, but high-performance scintillation demands much more. Occasional producers or traders often offer lots that look suitable—until users attempt long counting runs or work below ambient background. We examine every batch under simulated field conditions, running time-based decay, spectral resolution, and fluorescence lifetime measurements. The accelerated testing schedule flags subpar heat stability, signal persistence, and color formation, which matter most for users logging thousands of hours per batch.
One aspect that often goes unnoticed is the impact of PPO's physical form. Grain size and surface area affect solubility, especially in fully loaded cocktails. We control crystallization to ensure a reproducible, easily handled particle size. Clumping, excessive static, or caking introduce measurement drift and unnecessary preparation delays. Our experience with various clients—from radiochemical suppliers to university research groups—shows direct feedback: cleaner solubility curves, less glassware fouling, and no precipitate residue even at high loadings.
Sourcing PPO from the open commodity market exposes users to “commodity drift,” where the advertised product characteristics differ from the real chemical makeup. Our customers count on a stable product profile because we blend incoming feedback from physicists and analytical chemists directly into batch standards. For instance, widespread reports about faint color casts at the finish line prompted us to tighten filtration parameters back in the 2000s.
Refining this compound at production scale means walking a line between cost, yield, and customer value. We recycle solvents using closed-loop systems designed internally, monitor for trace leachable organics, and replace contaminated filtration lines at the first sign of batch deviation. Technicians who run our crystallizers daily know which minor changes alter product usability in the field.
Users gravitate to our PPO when low-level beta counting or intricate gamma discrimination matter most. Environmental labs, nuclear facilities, and health physics teams relying on fast, precise reporting see reduced recalibration frequency and lower maintenance costs. PPO's intense, narrow-band emission without side scattering means that highly specialized counters—those measuring trace radioisotopes for legal compliance or research—gain genuine value over cheaper alternatives.
In fast neutron detection, PPO acts as a primary fluor, converting excitation energy into detectable UV emission. This eliminates the need for “doped” cocktails or complex energy-transfer molecules in most standard cases. The chemical backbone remains stable under routine storage and real-world shipping conditions, retaining optical clarity, even after weeks on the shelf or transport in non-ideal environments.
A handful of other organic chemicals fill similar roles—like p-terphenyl, bis-MSB, or butyl-PBD—but PPO provides one of the best balances between light yield, emission lifetime, and chemical resistance. Mass spectra and quantum yields we have recorded show PPO outcompetes competitor solutes under typical counting conditions. Light output in polystyrene or liquid cocktails remains reproducible without dependence on additives or non-standard solvents. This reliability removes guesswork, letting users focus on calibration curves and decay profiles rather than the variability of the detection medium.
Beta resolution improvements with other commercial solutes often come at the expense of solubility or shelf life. We see time and time again that attempts to substitute PPO with lower-cost solutes or blends backfire, forcing more frequent cocktail changes and higher background readings. Environmental survey labs tracking low-level tritium or other beta-emitters have validated that our PPO keeps standard curves stable weeks after mix preparation.
We work closely with customers implementing high-throughput counting, sharing best practices about mixing protocols and storage methods. Our technical teams emphasize airtight, moisture-tight containers and dark storage to further prolong shelf life. While this sounds basic, repeated feedback shows that small changes in handling can make the difference between a smooth measurement regime and a problematic round of recalibration.
Long-term operators report insignificant yellowing or oxidative damage, even after multiple open-close cycles at the bench. Personnel can trust documented batch stability with confidence, reducing the risk of sample waste or measurement error due to solute degradation. We steer clear of unnecessary packaging changes or blended bulking agents, focusing on a lean, consistent supply chain that keeps product quality at the forefront.
The global chemical supply chain has seen volatility in recent years. Substituting feedstocks or outsourcing purification can undermine solute reliability, especially for users running critical measurements. We responded to disrupted supply chains by maintaining multiple local sources for base materials, holding buffer stocks, and qualifying secondary purification tools in-house rather than risking uncontrolled batch variation.
Any rush to cut corners manifests as increased impurities downstream—something modern spectral analysis picks up almost instantly. Persistent effort in-house, regular third-party validation, and rapid-response customer feedback loops close the door to these silent failures. Maintaining proper worker training goes hand-in-hand with safe, consistent product—staff in our plants know what failures look like and correct course before substandard material reaches customers.
The measure of a good batch comes not from test tubes but from dozens of end users reporting on the ground. Environmental radiologists, medical labs monitoring tracer isotopes, and physics professors teaching the next generation send back both data and narrative. They notice faster startup times, fewer maintenance tickets for fouled counters, higher throughput for regulatory testing, and, most importantly, greater confidence when reporting compliance data to oversight agencies.
Repeat orders often come not through marketing but from word of mouth among research consortia and professional networks—evidence that targeted, user-focused chemical manufacturing trumps broad claims every time. We act on properly gathered user reports: requests for more granulated or dust-free product lines up with modification to our finishing steps in production, while feedback on better labeling or updated technical bulletins leads us to invest in improved packaging and documentation.
Supplying PPO is more than just shipping a chemical; it’s about enabling better science and faster innovation across disciplines. Our team maintains open lines with researchers pushing the limits of low-level counting, whether cataloging environmental changes, verifying drinking water safety, or supporting radiopharmaceutical development.
Our practice involves continuous improvement, both driven internally and shaped by the changing needs and measurements our users face on a daily basis. Modern advances in detection, new synthesizer designs, and updated regulations all filter back to the chemical bench where our compounds are made and tested. We put each lesson into practice not out of compulsion, but because improved science drives real results—accurate environmental surveys, reliable tracer studies, or early warning for system failures in nuclear plants.
Producing PPO for scintillation spectrometry reveals the critical difference between chemical manufacture and simple distribution. Traders or brokers might advertise the same empirical formulas, but only with a sustained culture of quality, direct oversight, and responsive support can users execute their mission without interruption. Day-in and day-out control of every production detail allows us to shoulder the responsibility for each user's result—an obligation no intermediary can fulfill.
Our manufacturing plant integrates input from every stage of the research and industrial pipeline, reinforcing that this isn’t a faceless commodity. Instead, consistent quality, validated by real-world feedback and constant technical improvement, stays embedded in every unit supplied. Technicians, bench chemists, and field operators get more than a chemical—they get a partner in pursuit of clarity, accuracy, and dependable results.
The landscape for radiation detection evolves rapidly. New types of detectors, stricter environmental policies, and global cooperation for nuclear safety demand substances free from legacy unknowns or uncharacterized contaminants. Through all these changes, our core commitment to PPO quality stays fixed. We continually research better synthesis steps, refine analytical tools, and invite ongoing collaboration with advanced users in the field.
PPO remains one of the cornerstone materials in scintillation detection thanks to its predictability under real laboratory and field conditions. Every batch represents a tightly controlled effort in material, technique, and accumulated know-how. Every scientist or engineer seeking dependable, high-yield scintillation can trust they are receiving more than an ingredient—they are leveraging the better part of a century’s worth of direct, hands-on manufacturing experience.