|
HS Code |
211061 |
| Chemical Name | 1-Ethynyl-4-fluorobenzene |
| Cas Number | 403-81-0 |
| Molecular Formula | C8H5F |
| Molecular Weight | 120.13 |
| Appearance | Colorless to pale yellow liquid |
| Boiling Point C | 161-163 |
| Melting Point C | -27 |
| Density G Ml | 1.07 |
| Refractive Index | 1.554 |
| Flash Point C | 46 |
| Pubchem Id | 90941 |
| Smiles | C#CC1=CC=C(C=C1)F |
As an accredited 1-Ethynyl-4-fluorobenzene factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 1-Ethynyl-4-fluorobenzene (25g) is packaged in a sealed amber glass bottle with tamper-evident cap, labeled with safety details. |
| Shipping | 1-Ethynyl-4-fluorobenzene is typically shipped in sealed, chemical-resistant containers in compliance with DOT/IATA regulations as a flammable liquid. Packaging includes UN-certified bottles, clearly labeled for hazardous contents. Shipping is restricted to authorized carriers with appropriate documentation and handling instructions to ensure safety and regulatory compliance during transportation. |
| Storage | Store **1-Ethynyl-4-fluorobenzene** (Sigma Aldrich/Merck/TCI, Chemical Grade) in a tightly sealed container, in a cool, dry, and well-ventilated area away from sources of ignition and incompatible materials such as strong oxidizing agents. Avoid exposure to direct sunlight. Ensure containers are properly labeled. Follow standard flammable liquid storage guidelines, including appropriate fire safety measures and secondary containment where necessary. |
Competitive 1-Ethynyl-4-fluorobenzene prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
It’s not every day that a new aromatic building block reshapes your perspective on synthesis, but 1-Ethynyl-4-fluorobenzene regularly brings that sort of practical value to the lab. We’ve spent years refining our own process for producing this compound, focusing on consistency in both purity and physical form, understanding that downstream efficiency rests on upstream discipline. The molecular identity—C8H5F, with its characteristic ethynyl linkage at the para position to the fluorine—seems simple enough on paper. In practice, achieving reproducible purity and absence of side products demands far more than tallying raw material specs. That’s where hands-on experience makes a defining difference.
In direct feedback with medicinal and process chemists, it’s clear there’s no substitute for trace transparency. Our batches run at a minimum of 99.0% GC confirmed purity, commonly meeting or exceeding 99.5%. This isn’t a boast; it’s a necessity. Unexpected by-products, water, or yellow discoloration can undermine hydrogenation, Sonogashira coupling yields, or metal-catalyzed transformations. The ethanolic odor, the faintly oily feel, and the sharpness of the fluorinated ring all inform us long before gas chromatography or NMR confirms what our eyes and nose already suspect. Subtle differences in color or smell can flag the presence of trace halide, phenylacetylene, or oxidized fragments—tiny levels, but enough to ripple through your downstream steps.
The compound comes as a clear, barely yellowish liquid, boiling near 156-158°C. Our practitioners know that water content matters. We regularly go below 0.1% and document Karl Fischer test data for transparency. Some rivals deliver with looser moisture or peroxide control, but residual solvents or traces of stabilizers can complicate catalyst evaluations, especially in scaled-up reactions. Over years of scale-up from bench to pilot reactors, we have optimized both batch size and temperature management. Our vessels are equipped with specialty glass, maintaining inert atmospheres during distillation and transfer to block any atmospheric oxidation which can give rise to colored impurities.
Why does 1-Ethynyl-4-fluorobenzene find a regular place in both exploratory medicinal synthesis and the larger-scale production of advanced intermediates? Its para-fluoro group is far from decorative. We’ve seen firsthand how fluorine profoundly influences electronic behavior. It changes acidity, guides regioselectivity, and tilts the odds toward key intermediates in C–C bond-forming reactions. Pair the fluorine with the terminal alkyne and you get exceptional versatility for Sonogashira couplings, click chemistry, and borylation routes, as well as rapid halogen dance strategies. Many research teams report that this molecule helps create libraries of drug-like heterocycles where tuning bioavailability and ligand-receptor fit turns on a dime with judicious fluorine placement.
Several of our long-term partners use 1-Ethynyl-4-fluorobenzene in generating functionalized oligomers and polymers for OLEDs and advanced imaging. The electron-withdrawing fluorine, paired with that sp-hybridized carbon, lets users fine-tune optical absorption and emission. In our own technical evaluations, substituting the para-fluoro with other halogens consistently shifts product reactivity, melting points, and photophysical profiles. With growing demand for smart materials, it’s no surprise this molecule finds steady use in exploratory development beyond just pharmaceuticals.
Mistaking 1-Ethynyl-4-fluorobenzene for 1-ethynyl-benzene—or even for meta- or ortho-fluorinated analogs—can lead to headaches. Clients have shared stories of unexpected NMR splits or product yields tracing back to batch confusion. Reactivity in cross-coupling reactions differs more than theory would predict. We regularly demonstrate, for example, that electronic effects from the para-fluorine atom accelerate oxidative addition and stabilize key intermediates, smoothing coupling steps. Substituting with a chlorine, bromine, or a methyl group does not replicate this effect—resulting in distinct conversion rates, impurity profiles, and even catalyst poisoning risks. Direct side-by-side runs eliminate debates over which substitution delivers clean yields or sharper selectivity, and our production notes record these outcomes to better advise custom applications.
Beyond academic comparison, practical considerations matter. The odor thresholds, volatility, and ease of handling of 1-Ethynyl-4-fluorobenzene all stand out versus chlorinated or nitro-analogues. Where other halogenated ethynylbenzenes can evoke worker discomfort or field complaints, ours shows a mild aromatic odor and doesn’t linger on the bench or in jackets—a day-to-day difference that technicians appreciate. Stability is also a deciding factor. We monitor peroxides and maintain nitrogen headspaces to limit photodegradation or accidental peroxide formation. Some manufacturers or traders do not take comparable measures, leading to unpleasant surprises in larger scale, where even small instabilities can ferment into major process deviations.
We have seen newcomers to this field be seduced by phrases like “industry grade” or “suitable for all applications.” The actual requirements for a consistently high-performing batch depend entirely on what our clients intend to do. Some merely need a high-purity, easy-to-handle starting material for bench-scale transformations. Others intend to run kilogram-level reactions with tight timelines and downstream quality constraints. Our own processes adapted as pharma and OLED customers became more demanding. High-resolution HPLC and NMR data, free from fudge factors, have become the daily currency of trust. Clients occasionally request tailored packing, custom inert atmospheres, or direct solvent dissolution before shipment, and we respond to these requests from direct bench experience, not just catalog claims.
From sourcing raw fluorobenzenes to controlling reduction environments, every production stage has been stress-tested for real-world reliability. When a client raises an issue about trace solvents or minor UV absorbances, our manufacturing staff steps into the conversation, explaining how our phase separations and glassware design prevent such issues. We operate continuously, not batchwise, producing and transferring under positive pressure so air and moisture cannot creep in. These small investments add up during scale-up, preserving reactivity and reducing rework for partners every single time. No two runs are truly identical, but a decade of operations reveals patterns and secrets that no university textbook or supplier’s data sheet can touch.
It’s all too common to assume that a percent or two of impurity will fade away in the noise, especially if you’re using excess reagents or aggressive purification. With 1-Ethynyl-4-fluorobenzene, even sub-percent contamination has a way of echoing through subsequent steps: as catalysts deactivate, by-products accumulate, and chromatographic timelines balloon. One illustrative example involved a multi-gram cross-coupling in a pharma partner’s pilot plant, where a single drifting impurity shifted peak resolution just enough to muddy the analytic signature. The batch had to be rerun—not because specs had slipped, but because subtle inconsistency silently built up at the start. From that point, we introduced additional inline monitoring and stress-tested our distillation protocols.
Experienced chemists and engineers know good color and odor control can save hours of troubleshooting. Achieving a sharp, transparent product not only signals purity but also simplifies visual inspections and in-line monitoring systems. If a product arrives faintly yellow or with traces of aromatic impurities, questions multiply: was the raw material recycled? Did atmospheric oxygen intrude? Is stabilizer present? Our investment in specialized column packings and argon-pressurized delivery gives clients the peace of mind that neither color nor content will surprise them at the worst possible time.
Ongoing dialog between manufacturer and end user is the foundation of trustworthy supply. No matter how polished marketing claims sound, unexpected production realities shape the difference between adequate material and consistent process reliability. A polymer chemist needing predictable coupling performance for OLED prototyping holds different expectations than a pharmaceutical innovator balancing tight regulatory deadlines. In either case, small changes in residual moisture or solvent carry-over can derail entire project timelines, trigger extra clean-up steps, or skew activity measurements. Rather than react to problems after the fact, we welcome trial runs and direct technical exchange with clients before a core material ever reaches a full-scale reactor.
The greatest reward comes when repeat customers report "no surprises" after multiple campaigns. That testimonial outvalues any glossy data sheet or generic certificate. It tells us our process control does not just happen on paper. In one case, a repeat medicinal chemistry customer documented that our batch-to-batch purity variation over 18 months came in as the lowest in a survey of six leading suppliers. Their yield improvements and reduced side reactions directly reflected this fact, helping to accelerate project timelines.
It would be easy to list out minor chemical differences between 1-Ethynyl-4-fluorobenzene and ortho or meta isomers, or swap in other aryl acetylenes like phenylacetylene or 1-ethynyl-4-chlorobenzene. In head-to-head application tests, subtle shifts emerge that change entire process outcomes. The para-fluoro group creates a unique electronic profile, facilitating fast, high-yielding couplings and rapid subsequent functionalizations. Our synthesis teams ran dozens of comparative NMR and HPLC studies under matched conditions, finding that 1-Ethynyl-4-fluorobenzene consistently gives sharper, cleaner runs with less tailing and decomposed byproduct.
In OLED screening, this molecule imparts lower turn-on voltages and better blue-shifted emission than its para-chloro and para-methyl siblings. The switch from fluorine to heavier halogens drags down emission profiles and crystallinity. In small-molecule pharmaceutical applications, we have observed that para-fluorine helps intermediates resist hydrolysis without extra protecting groups. Clients using the chloro or bromo version often confront lingering byproducts and longer purification timelines. We have documented cleaner end products and higher overall conversion when using the fluorinated variant, saving partners time and labor at each stage.
Scaling ethynyl-arene chemistry brings challenges. Bottlenecks, safety concerns, trace impurity knock-on effects—all require a hands-on manufacturing mindset. Acetylene chemistry always demands respect because of its reactivity and propensity to generate hazardous side-products if water, oxidants, or transition metals get involved at the wrong stage. Our entire process chain tracks and logs batch parameters and critical control points, empowering us to flag unexpected readings before they become problems later. If an operator hears an unusual hiss during transfer, or the distillation temperature drifts, protocols trigger extra gas chromatography runs and in-person visual inspections.
Improving safety and consistency has meant trade-offs with throughput. Long-run manufacturing means patience. We have learned not to prioritize production speed ahead of quality. A run may take several extra hours, but batch rework and customer complaints exact a higher toll. The workflow now integrates triple-filtration, cold-stabilization, and oxygen-free storage before shipment. We bottle and seal under argon, eliminating the risk of atmospheric ingress. Downstream, these steps ensure that users never discover peroxide formation or performance drops after the fact. Each improvement comes from previous shortfalls—experience is paid for every step of the way.
Strong partnerships have driven technical improvements over the years. Early on, a team scaling up OLED building blocks highlighted difficulties with color drift and batch variability from other suppliers, motivating a revamp of our filtration and distillation practices. Another research customer developing fluorinated heterocycles requested regular HPLC trace uploads alongside each batch, pushing us to establish digital reporting integrated with lot IDs. These weren’t one-off fixes but ongoing adjustments, baked into how we approach both aqueous workups and solvent recovery. Years later, that same customer continues to provide feedback, catalyzing further tweaks—finer column packings, freezer storage, improved headspace protocols.
Collaboration doesn’t just improve the finished product—it also hones our technical support. Sharing real-life troubleshooting tips, application notes, and workup caveats with our users avoids nasty surprises and consolidates trust on both sides. These exchanges often anticipate bottlenecks in scale-up or pilot production, enabling smoother transitions from research grade to kilogram campaigns. In an increasingly regulated and competitive environment, the confidence built from consistent performance outweighs generic guarantees and smooth talk. In this respect, our pool of returning clients tells a better story about our standards than any sales pitch could manage.
The responsibilities attached to fluorinated chemistry carry through from research bench to waste stream management. Readers might hear little about this from bulk traders, but as manufacturers, we invest constantly in emissions abatement and recovery. Our production facilities reclaim solvents at every opportunity. We have eliminated venting of volatiles, using activated carbon and cold traps to capture even trace emissions. Wastewater streams get pH balancing, carbon filtration, and real-time monitoring before treatment. Cycled hydrogen and nitrogen save both costs and environmental impact. We have also worked to reduce staff chemical exposures to effectively zero, introducing closed transfer systems and robust personal monitoring programs. These incremental changes now define daily operations here.
Reflecting on years of hands-on production, living alongside 1-Ethynyl-4-fluorobenzene reveals that chemistry is never truly static. The textbook formula, the analytical standard, the finished drum—none exist in a vacuum. Small, unglamorous deviations cause the biggest headaches for end users, so direct bench know-how and rigorous transparency shape every liter we fill. Each stage, from raw feedstock to final bottle, runs on accumulated experience, not just SOP checkboxes. End users trust material born of firsthand feedback and steady iterative improvement; the rest is marketing. We remain keenly aware that every batch may form the starting point for your research breakthrough or your scaled production run. So we measure and monitor, adjust, and refine—building confidence, one shipment at a time.