HS Code |
812137 |
| Product Name | 1,4-Bis[2-(5-phenyloxazolyl)]benzene |
| Common Abbreviation | POPOP |
| Application | Scintillation spectrometry |
| Chemical Formula | C24H16N2O2 |
| Molecular Weight | 364.40 g/mol |
| Appearance | White to off-white powder |
| Purity | Typically ≥99% |
| Melting Point | 210-214°C |
| Solubility | Soluble in organic solvents such as ethanol, toluene, benzene |
| Fluorescence Emission Maximum | 410 nm (in solution) |
| Cas Number | 27322-14-3 |
| Storage Conditions | Store at room temperature, protect from light |
| Synonyms | POPOP, bis-POPOP |
| Sensitivity | Sensitive to prolonged light exposure |
| Use Level | Typically 0.1–0.5% w/v in scintillation cocktails |
As an accredited 1,4-Bis[2-(5-phenyloxazolyl)]benzene [for scintillation spectrometry] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging for 1,4-Bis[2-(5-phenyloxazolyl)]benzene (Sigma Aldrich, 1 g) is a sealed amber glass bottle with tamper-evident cap. |
| Shipping | 1,4-Bis[2-(5-phenyloxazolyl)]benzene [for scintillation spectrometry] is shipped in secure, chemical-resistant packaging to prevent contamination or degradation. It is handled as a non-hazardous material under standard transport regulations, with temperature and light protection recommended. Shipping documentation includes product labeling and material safety data for regulatory compliance and safe handling. |
| Storage | **Storage Description for 1,4-Bis[2-(5-phenyloxazolyl)]benzene [for scintillation spectrometry]:** Store the compound in a tightly sealed container, protected from light and moisture, at 2–8°C (refrigerator). Keep in a cool, dry, and well-ventilated area, away from incompatible substances such as strong oxidizers. Ensure proper labeling and avoid prolonged exposure to air to preserve chemical integrity. Use appropriate personal protective equipment during handling. |
Competitive 1,4-Bis[2-(5-phenyloxazolyl)]benzene [for scintillation spectrometry] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every batch of 1,4-Bis[2-(5-phenyloxazolyl)]benzene that leaves our plant reflects both decades of experience and a sharp focus on what practitioners in scintillation spectrometry truly care about—absolute purity, consistent yield, and clear, reliable signals. This material, widely known in the field as POPOP, has long served as a standard in the landscape of secondary scintillators, and we understand why our clients, from physicists to industrial labs, count on it for their measurements. We’re a manufacturer, not a repackager, so what comes from our facility meets traceability at every step, right down to the starting benzene ring.
Chemists and engineers working with liquid or plastic scintillation solutions demand certain features. POPOP brings high photostability and excellent quantum efficiency, maximizing photon yield in systems where even minor impurities can ruin a spectrum. Each crystallization run is tuned to achieve optimal particle size and morphological consistency, so filtration or mixing downstream rarely becomes an issue. Over the years, we've monitored shifts in detector technology—coincidence electronics, PMT improvements, digital readout—and we've always adjusted our process controls accordingly. When users report anomalies or light loss, it’s rarely the fault of the POPOP; impurities elsewhere in the matrix or environmental factors often explain the variation.
Our current main production line focuses on molecular weights and lot numbers with full traceability. Rigorous chromatography and spectral analysis ensure that the product consistently matches or exceeds published specifications: an absorption peak around the mid-350s nanometer range, emission tail centered in the 410 nm region, with purity above 99.5% by HPLC and melting point within a tightly defined window. All batches undergo full-scale testing for residual solvents and possible trace contaminants like heavy metals, as these have a direct, measurable effect on total light yield and background. In years past, we have seen what happens when loosely controlled syntheses (often by non-producers) yield off-spec batches—erratic detector performance, yellowing in plastics, or even outright test failures. This substance cannot tolerate shortcuts.
Producing POPOP at scale calls for more than textbook chemistry. Early stage syntheses in small glassware typically yield clean product, but unexpected byproducts show up quickly when moving to pilot or industrial scale. We’ve learned this lesson the hard way, refining our solvent extraction protocols, examining ripple effects from small changes in reaction temperature, and deploying in-line monitoring to catch variations while they’re still manageable. Customers in high energy physics expect repeatability; when a detector is reloaded, it cannot start out with less sensitivity than before. This is why we maintain controlled storage and inventory protocols. Thermal cycling, moisture exposure, and prolonged shelf time can all affect performance. So we take pains to keep environmental conditions consistent between final purification and shipping.
Users most often deploy POPOP in solutions with organic solvents like toluene or xylene, though we have seen applications branch into custom engineered plastic matrices as well. The spectral shift offered by POPOP, moving ultraviolet excitation energy into the visible blue region, aligns perfectly with standard photomultiplier tube sensitivity. This property increases counts in low-level detection protocols, reducing the need for excessive amplification down the line. Physical characteristics—free-flowing crystalline powder, low hygroscopicity—simplify blending into cocktails or polymer pellets, whether customers mix on site or request custom blends from us. Sometimes labs pursue substitute scintillators as a cost-saving measure, only to double back after observing noise and drift. They soon recognize that the signal clarity and long-term stability POPOP affords are rarely matched by those alternatives.
Anyone who’s worked at the bench recognizes the main threat to performance—contamination. Even a few parts per million in certain ions, or traces of plasticizers and dust, introduce unwanted backgrounds that swamp weak signals. We go beyond classical purification; zone refining and flash chromatography have become drop-in stages in our process. Our experience shows that ignoring these steps leads to increased yellowing and nonlinearity after only a few weeks under irradiation. Certification with each lot does not stem from box-checking—our spectrometry team runs tandem tests of the critical properties for each order, not just random sampling. This sort of diligence differentiates the real manufacturer from middlemen who never see the inside of a reactor vessel.
Some competitors offer cheaper secondary wavelength shifters, or electronically similar analogues, but these tend to exhibit lower stability under strong radiation fields or extended illumination. Over the years, we have reverse-engineered several such competing materials and traced issues to micro-level impurities or polymerization catalysts left in the product. The resulting drift in emission profile, subtle color quenching, or even material clumping tends to become apparent long after the purchase order has been completed. We hear directly from customers who switched back to our material after one too many failed runs; their results reinforce that origin and quality control consistently matter more than cost savings that vanish on the first botched experiment. There’s real-world cost in chasing a few percentage points of savings only to lose hours calibrating equipment for inferior material.
Regular dialogue with global research groups and analysts keeps us sharp. Big science collaborations—working on neutrino detection, high-energy physics, or environmental surveillance—frequently relay performance data and failure analyses. This feedback cycle pushes us to model each new threat to performance, from the interaction of trace organics with solvent blends to the slow buildup of degradation products under sustained high-voltage excitation. Results from the field rarely match expectations from textbook conditions. Actual experiments introduce oddball solvents, unpredictable temperature swings, and even cross-contamination from unanticipated sources. Our chemists maintain open lines to these teams, adjusting our quality assurance to match the demands of each breakthrough. Material crafted for “ideal” conditions often falls short once given to a real-world technician facing dirty glassware or unusual excitation sources.
The rigors of actual detector operation push us to maintain a consistency that bulk commodity producers struggle to achieve. In a typical high-throughput lab, users cycle through liters of scintillation liquid each month. They don’t want to recalibrate every time a new bottle is opened. Unwanted batch-to-batch variability becomes a true profit drain, not just a hassle. Keeping emission and absorption characteristics locked within spec comes from an investment—dedicated reactors, regular recalibration of analytical standards, and ongoing staff training. Raw materials never come from the lowest bidder; our sourcing strategy focuses on trusted suppliers who understand that trace impurities in precursor chemicals ultimately show up in PMT counts at the end user facility. The laboratory’s frustration during troubleshooting speaks volumes—so we solve upstream, not downstream.
New detector technologies demand new supporting chemistry, especially as systems grow more sensitive and miniaturized. Our R&D teams track incremental changes in solvents, polymers, and the specs that define success. A slow trend toward lower-wavelength excitation and ultra-high spatial resolution puts increased stress on the molecular stability of fluorescent additives like POPOP. We’ve taken steps to reduce photobleaching by exploring additive stabilizers, working with university partners to lengthen usable service life and suppress artifact formation. As more sensors move to solid-state readouts, compromises in chemical performance tend to surface immediately; our goal stays focused on staying ahead of these shifts, updating our manufacturing process as soon as the field starts changing. The cycle is relentless, but no lab benefits from falling behind.
Our commitment stretches past the product itself. Facilities storing and using POPOP must comply with modern safety regulations and waste disposal protocols, particularly when dealing with halogenated solvents and high-voltage equipment. We routinely supply supporting analytical documentation and guidance on minimizing exposure or waste. Not every producer takes this hands-on approach—the risks of neglecting worker safety grow every year as standards evolve. Strong relationships with regulatory bodies guide the evolution of our internal safety measures. All for the simple reason that the material leaves a lasting trace wherever it’s used. One misstep in downstream use, often rooted in poor understanding of batch differences, costs more than up-front diligence. Direct feedback from our customers about labeling, traceability, and safe handling plays an integral role in how our operations adjust and improve.
Conversation with long-term partners in clinical and academic labs revealed a point many suppliers overlook: shelf stability. The best performance on day one means little if the powder attracts moisture or decomposes within a season. Our attention to micro-level drying and inert gas packing aims to preserve initial quality, especially for users who order in large lots for phased deployment. Chemical stability under storage also guards against the onset of coloration, which can quickly alter light output and render months of accumulated data suspect. We have tested aging under various humidities, lighting, and temperature cycles, and we modify our logistics practices based on those results. These aren’t market claims; these arise from years spent running our own detection experiments where troubleshooting points always lead back to materials improperly handled, rushed, or relabeled by a third party.
Every chemist has a story about having to troubleshoot low signal or unexplained noise in a detector assembly. We routinely field questions about compatibility with cocktail compositions, new plastics, or nonstandard solvents. Decades of in-lab and field deployment experience tell us: POPOP tolerates a wide range of companion materials, but certain aggressive oxidizers or improper mixing protocols quickly degrade performance. Each time a lab faces a performance drop after trying a new solvent, we step through the test conditions, seeking out chemical incompatibilities or failures in sample prep. This direct engagement with users lets us recommend process tweaks—extra freeze-drying, different mixing orders, or alternate solvent systems. Unlike products passed through a distributor, our direct support avoids generic answers. Each challenge, from particle aggregation to storage-induced off-gassing, delivers another data point for the next round of improvements.
A cheaper secondary scintillator might look enticing in an annual budget, but we know from user feedback and our own testing that low-cost materials often outperform only on select metrics, missing what matters most: lasting signal stability, predictable emission under varied loads, and long service life. Every time a customer returns after testing another supplier, their report points to the same lesson: the purchase cost fades behind the costs of recalibration, false negatives, or lost measurement time. Most labs working in high-sensitivity detection don’t operate with unlimited budgets. They need to trust the source, trust the lot, and trust that repeat performance holds. We hear front-line techs—our fellow chemists—emphasize this point year after year. Real-world cost is not just on a spreadsheet; it’s in downtime, frustrated project leads, and data that doesn’t match what theory expects.
Having spent years refining every synthesis, adapting to evolving analytical techniques, and learning from problems that rear up on the lab floor, we stand by the fact that POPOP’s source and method matter far more than branding or marketing. Users who have tested multiple sources recognize the subtle distinctions—crystal habit, color stability, UV response—that signal deep differences in underlying chemistry and process integrity. Each batch carries the fingerprints of its maker: every solvent, every purification, every QC test. Copycat products or relabeled reagents, often coming from bulk commodity markets, don’t sustain performance over time or under heavy cycling. In the hands of an experienced analyst, even small fluctuations in light emission or fading under sustained load trace back to corners cut or controls relaxed somewhere along the supply chain. As direct manufacturers, we guard that chain relentlessly, because no experiment wants to hinge on a variable it can’t track.
From early-stage setups to sophisticated, multiparameter detection arrays, we collaborate with users seeking to tailor their systems. Sometimes new questions arise about combining POPOP with experimental fluorescent partners or unusual substrates. Our in-house team examines each scenario, guiding clients toward the best approach, offering troubleshooting assistance, and if needed, adjusting our own blend or packaging to help. We treat each request as a source of new knowledge; often customer challenges reflect new directions for the field rather than simply routine support. Without the perspective of someone who has run the experiments, fixed the unexpected, and haggled over precision down to the last photon, technical guidance amounts to little more than guesswork. This is how we have built lasting relationships throughout the research and industrial user communities—not through one-off shipments, but through direct feedback, nimble adaptation, and staying invested in the daily realities of those who measure the world.