Yudu County, Ganzhou, Jiangxi, China sales3@ar-reagent.com 3170906422@qq.com
Follow us:



Tris-EDTA Equilibrated Phenol Solution: A Closer Look at Its Role and Relevance in Molecular Biology

Tracing the Roots: Historical Development

Back in the early days of molecular biology, extracting clean, intact genetic material challenged even the sharpest minds. Researchers turned to phenol, not out of convenience, but because this pungent liquid pulled DNA and RNA from the crowded soup of proteins and debris. The simple phenol-chloroform extraction soon became synonymous with genomic research. Over time, scientists grew wise to phenol’s dangers and instability, especially when water content crept in, causing oxidation and contamination. Enter Tris-EDTA equilibrated phenol—no ordinary solvent. Tris, a mild alkaline buffer, preserves nucleic acids’ fragile state, and EDTA binds stray metal ions that could trigger unwanted breakdowns. This formulation didn’t land by accident; it took years of frustration-laced trial and error before labs settled on this buffered phenol as a mainstay for DNA and RNA preparation.

What Sets Tris-EDTA Phenol Solution Apart

This solution balances strength with subtlety. Phenol itself disrupts cell membranes and denatures proteins with brute force, making it excellent for separating nucleic acids from the rest. The Tris buffer maintains a stable pH, safeguarding the precious genetic material through the stormy mixing and spinning that define extraction protocols. EDTA, a chelating agent, locks down divalent metal ions like magnesium and calcium—these could otherwise activate nucleases, enzymes that attack the very DNA and RNA researchers aim to study. The result: a solution that keeps nucleic acids protected while efficiently stripping away proteins and contaminants.

Physical and Chemical Properties

Tris-EDTA equilibrated phenol carries a strong, distinctive odor and shows up in the lab as a clear to slightly yellowish, oily liquid. Its density tips heavier than water, so after mixing with an aqueous sample, it settles on the bottom layer, neatly capturing unwanted proteins in the process. The presence of the Tris buffer means that the pH hovers around the neutral to slightly alkaline range—just right for keeping DNA happy and safe from acidic hydrolysis. This solution is always kept in brown glass bottles or other light-resistant containers because exposure to light accelerates oxidation, which can degrade both phenol and the extracted genetic material. Oxidized phenol not only smells worse but also can lead to experiments going sideways, so freshness and storage conditions matter just as much as the ingredients.

The Method Behind Preparation

Years in the trenches of the lab have shown me that prepping Tris-EDTA equilibrated phenol demands more caution than many expect. It starts with liquefying solid phenol, usually by gentle warming. This isn’t just about convenience—the crystals form as phenol pulls moisture from the air, especially below 40°C. Once liquefied, it needs several washes with 0.1 M Tris buffer (often pH 8.0) until the aqueous phase’s pH lines up with expectations. Adding EDTA ensures no stray nucleases survive to destroy samples. Each wash helps remove peroxides and acid byproducts, which, if overlooked, can sabotage an entire experiment. The final emulsion, after a night’s rest—usually at 4°C so nothing degrades—separates into two layers, and only the phenolic layer, now balanced and buffered, makes the cut. This careful, methodical process underlies every reputable batch found in research freezers today.

Watching the Solution in Action: Chemical Reactions & Modifications

Anyone who has spent hours pipetting and vortexing knows phenol is tough on proteins—it tears apart their structure, dividing the aqueous and organic phases and trapping cellular debris. Tris buffer swings in to keep the environment stable during this violent separation. EDTA binds up metal ions, heading off enzymatic trouble before it can start. Occasionally, labs add a dash of isoamyl alcohol or chloroform alongside the buffered phenol, boosting the separation’s clarity and yield. But even these “improvements” come with risks; mismeasuring or mishandling them can increase toxicity or lead to poor phase separation. These reactions and modifications demand the sort of hands-on vigilance and care that simply can’t be replaced by automation or shortcuts. Proper chemical control is not a box to check off—it’s the silent partner in every clean band of DNA seen on a gel.

Different Names in Different Labs: Synonyms & Product Names

In catalogues, lab notes, and casual hallway conversations, scientists toss around names like “buffered phenol,” “TE saturated phenol,” or “phenol:Tris-EDTA.” Each name points toward the same purpose: extracting nucleic acids with minimal loss or contamination. Even if a bottle sports a slightly different product name or comes from a different supplier, the core ingredients and workflow usually follow time-tested patterns. This is less about marketing and more about shared experience and trust in the reagents that underpin critical research.

Standards for Safety & Operation

No one walks lightly into a room reeking of phenol. This chemical seeps through latex gloves and can burn skin in minutes. Safety goggles are not optional. Double gloves, lab coats, and fume hoods draw a strict line between safe handling and reckless shortcuts. Spills cry out for immediate cleanup with absorbent pads and specialized disposal containers—never down the drain. Waste must find its way to licensed chemical disposal, not regular trash. These aren’t overblown precautions. Phenol has sent more than a few new researchers to the emergency room through careless contact. Training, clear warning signs, and a zero-tolerance approach to shortcuts keep labs safe and reputations intact. Stories that float through research communities about accidents with this solution aren’t just folklore—they’re warnings rooted in hard-earned lessons.

Where the Solution Makes an Impact: Application Areas

Every time a scientist publishes new sequencing data, phenol probably played a role somewhere along the way. Tris-EDTA phenol earns its stripes in extracting DNA and RNA from tough samples—plants packed with polysaccharides, animal tissues riddled with proteins, and even soil where every cell type competes for dominance. Forensics, ancient DNA recovery, agriculture, cancer research, and microbiome studies all rely on its reliable ability to deliver pure nucleic acid, ready for downstream applications. The consistency and purity it enables can make or break experiments that cost days or weeks. Automation in nucleic acid extraction may be growing, but buffered phenol remains the fallback for samples that stump other methods.

Pushing Forward: Research & Development

A chemistry that’s been passed from generation to generation in the lab rarely stands still. Researchers look for ways to limit toxicity and discard hazardous waste. Modifications, like adding antioxidants or searching for less toxic substitutes, reflect a drive toward both cleaner science and cleaner environments. Some stick with traditional phenol, while others pivot to silica-based or magnetic bead protocols. Despite newer technologies, the ability to troubleshoot and optimize classical methods like Tris-EDTA phenol extraction often distinguishes seasoned experimentalists from those with only robotic workflows under their belt. Persistence in refining extraction efficiency, increasing safety, and reducing exposure to harmful reagents never loses relevance in research circles.

Facing the Risks: Toxicity Research

Nobody can ignore the reality of phenol’s dark side. Its toxicity records stretch back decades, with symptoms from mild skin burns to severe systemic poisoning. Inhalation, absorption, or accidental ingestion sketches a troubling picture—nervous system depression, kidney and liver damage, and fatal outcomes aren’t impossible scenarios. Even brief, small-scale exposure can cause blisters and tissue necrosis. Lab protocols focus not only on minimizing incidents, but also on reducing environmental impact. Scientists spend time on bench-scale studies to find effective, less toxic alternatives or improved personal protective equipment, but phenol’s unique ability to disrupt proteins so completely means it never disappears from the toolbox. Regulatory agencies and institutional safety committees constantly review and update recommendations, keeping vigilance high.

The Road Ahead: Future Prospects

Younger generations entering research crave safer and greener alternatives. Automation, solid-phase extraction, and enzyme-based protocols eat away at phenol’s dominance, especially in high-throughput environments. Even so, certain samples stick stubbornly to old-school chemistry, making buffered phenol hard to fully retire. Promises of new solvents—maybe ionic liquids or biodegradable mixtures—linger in journals and conference presentations. So far, nothing quite matches the tried-and-true balance of complete extraction and cost-effectiveness offered by Tris-EDTA phenol. Progress blends optimism with respect for the lessons of the past, and with every small improvement, the gap between tradition and innovation narrows. Scientists keep watch, ready to trade out risky chemicals as soon as reliable, affordable, and accessible replacements stand up to the rigors of daily research.




What is Tris-EDTA equilibrated phenol solution used for?

A Lab Friend That Gets Results

Tris-EDTA equilibrated phenol solution might sound like one of those chemicals that only interests a small group of lab folks, but its job carries weight. Pulling pure DNA or RNA from cells ranks as one of the most demanding steps for genetic research, troubleshooting mysterious illnesses, or developing a new vaccine. Tris-EDTA phenol steps in right at that crossroads.

Pure Prep: Keeping DNA and RNA Happy

I’ve seen the difference preparation makes. You take a tube of mashed-up cells, add this specially prepared phenol solution, shake it hard, and the whole mess divides cleanly. Proteins, debris, and stubborn enzymes that love to chew up genetic material get pushed out of the way. This happens because phenol strips proteins out of the mix, while Tris and EDTA give DNA and RNA a safe zone. Tris holds the right pH, important for keeping nucleic acids snug and stable. EDTA keeps metal ions away, which blocks enzymes that could quietly chop up delicate RNA.

Why Scientists Choose This Blend

Plenty of folks attempt DNA isolation using pure phenol, but the story doesn’t end well without balance. Raw phenol has an aggressive streak, ruining more samples than it saves. Making phenol “friendly” by soaking it with Tris and EDTA solves that. Tris makes sure the environment stays just alkaline enough to give DNA and RNA some breathing room. EDTA grabs those floating metal ions, giving rogue enzymes less room to do damage. This careful mix raises the odds of getting clean genetic material — not just something that tests positive, but a sample good enough for sensitive tasks like PCR or next-generation sequencing.

Wasted Time, Missed Answers: What Happens With Poor Extraction

Cutting corners here means setbacks. In my experience, a weak extraction can throw off an entire week’s work. Contaminated DNA leads to failed experiments or garbage sequence data. Medical diagnostics, criminal investigations, and vaccine research all get held up when a bad prep sends folks chasing shadows. There’s a lot on the line — one contaminated prep means someone has to start again with patient samples, or a crop disease diagnosis can head in the wrong direction. With budgets and timelines hanging in the balance, quality pays off.

Modern Tweaks and Safe Practices

Lab safety always comes up when talking about phenol. That chemical burns skin on contact, and its vapors sting the lungs. Experienced team members never cut corners here — gloves, eye protection, and working under a hood are just standard practice. Over the years, alternatives like silica columns and magnetic beads have popped up. They offer convenience, especially for fieldwork or smaller labs. Even though these newer methods catch on, plenty of teams still trust the old Tris-EDTA phenol solution when yield and purity take top priority. Sometimes it’s about handling difficult tissues, or maybe it’s a matter of budget, but for hard samples or high-stakes experiments, it stays in rotation.

What’s Next?

Some researchers push for phenol-free tech, looking for ways to keep people and the planet safer. There’s progress, but not every switch-over proves as reliable with tough samples. The lesson isn’t to throw the old method away fast, but to weigh risks, rewards, and the job at hand. In the meantime, phenol with Tris and EDTA keeps showing up in protocols for DNA and RNA purifications that just have to work.

How should Tris-EDTA equilibrated phenol solution be stored?

Why Proper Storage Matters

Anyone in a molecular biology lab knows phenol comes with a major warning sign, yet tests often need it on deck. Equilibrating with Tris-EDTA doesn’t make phenol harmless, but this twist stabilizes the pH and protects nucleic acids during extraction. Storing it right means getting reliable results and staying safe. I’ve handled phenol before and, without proper care, shelf life shrinks and dangerous fumes fill the room. Trust me—a little attention to storage changes everything.

Keeping Quality and Safety in Check

Phenol, even after equilibrating, stays sensitive to light, air, and heat. Under the wrong conditions, phenol oxidizes, turning reddish-brown. This color means it’s gone bad and can compromise DNA and RNA samples. Fresh phenol is colorless to faintly yellow. Labs lose valuable time and resources when careless storage ruins a batch. The risks also multiply for anyone handling degraded phenol fumes; improper storage can leave inhalation or skin exposure hazards lingering in your workspace.

Best Storage Practices—From Experience

Based on years of bench science, storing Tris-EDTA equilibrated phenol solution starts with amber glass containers. The glass prevents chemical leaching and the dark color blocks out light, the culprit behind quick oxidation. Store containers sealed tightly to keep out air and water. Few things ruin phenol quicker than a loose cap, and accidental inhalation gets real when those fumes escape.

Temperature control matters just as much as the physical container. Most protocols point to storing phenol solutions at 2–8°C, right inside the fridge. This slows down oxidation and keeps the solution stable for a longer period. Don’t put it in the freezer; phenol thickens or even crystallizes, making later use a mess and remixing a headache. The refrigerator shelf set aside for corrosive or toxic reagents works best—far from food or anything consumable.

Some labs add an antioxidant like 0.1% 8-hydroxyquinoline to keep the phenol colorless longer, but it impacts downstream applications. Always check protocols before adding anything to the mix.

Labeling and Handling—Simple Steps Add Up

Accurate labeling turns chaos into order. Every bottle of Tris-EDTA equilibrated phenol solution should show the date prepared, who made it, and the composition. In busy labs, where bottles travel between benches, this habit saved my team from both wasted experiments and safety scares. Any sign of color change—ditch the bottle. Fresh solutions work best, so mix in small batches if usage isn’t regular.

Gloves, safety goggles, and a lab coat stop direct exposure. Work in a fume hood whenever opening or transferring phenol. Take spills seriously; neutralize with sodium bicarbonate or a dedicated chemical spill kit instead of paper towels.

Room for Change

Even with the best routines, mistakes surface. Regularly checking both inventory and expiration dates helps avoid bad surprises. Some institutions recommend rotation; old solutions out, new ones in. Sharing experiences across lab teams shortens the learning curve for new researchers.

Proper storage leaves no room for shortcuts. Safer workspaces and dependable results tie straight back to how we treat every bottle of Tris-EDTA equilibrated phenol solution. Paying attention isn’t just about ticking a box—it's about trust in your results and respect for your colleagues.

What is the recommended method for handling and disposing of Tris-EDTA equilibrated phenol solution?

The Realities of Lab Life: Respecting Dangerous Chemicals

Tris-EDTA equilibrated phenol solution isn’t an everyday kitchen chemical, and those who've prepped an RNA extraction know just how much respect it demands. One slip, and what starts as another day at the bench can turn hazardous or much worse. The sharp, sweet stench of phenol tells you straight up: careful handling isn’t optional. This material doesn’t care if you’re in a hurry or pulling a double shift; it can burn skin and eyes and wreak havoc on airways. That’s why knowledge beats false confidence every day.

PPE: It Actually Matters

Everyone has stories about “that one time” someone skipped gloves or forgot eye protection. Phenol takes that carelessness and pays you back with a chemical burn that just keeps on burning. Nitrile gloves, not latex, keep phenol off the skin. Lab coats and splash-proof goggles help defend against spills and accidents. Anything that touches phenol needs washing—never reuse gloves or towels, or you’re just spreading the hazard around.

Smart Practices at the Benchtop

Fume hoods exist for a reason. Phenol vapors sit heavy in the air and can irritate or damage lungs. Always work inside a properly running fume hood. I’ve seen too many shortcuts in over-crowded labs, but the quick fix can cost dearly in health and accident rates. Phenol bottles shouldn’t be left open or uncapped longer than absolutely needed. Tight caps, clear labeling, and centralized storage keep labs safer.

Disposal: More Than an Afterthought

Pouring chemicals down the drain isn’t just lazy; it’s dangerous. Phenol in municipal water plants? That’s a community health problem, not just a lab issue. Tris-EDTA in the mix may lower acidity, but it won’t make phenol “safe.” Liquid phenol waste goes into tightly sealed, clearly labeled containers. No mixing with bleach or strong oxidizers—bad chemistry releases toxic fumes or worse.

Every institution with a real research program has hazardous waste pickup and on-site disposal guidance. I’ve seen firsthand how clear, up-to-date signage and routine training stop mistakes before they spiral. Staff need to know who to call, where to store full waste bottles, and what never goes into regular trash or down the sink.

Training: Keeping Knowledge Fresh

One-time training fades from memory. Scheduled refreshers, hands-on demonstrations, and open discussion about past mistakes build a safety culture that saves time, money, and sometimes lives. Peer accountability plays a huge role. If you spot risky behavior—open bottles, no eye protection, broken hood alarms—say something. It beats writing accident reports or seeing someone’s career upended by burn injuries.

Looking Beyond the Lab: Environmental Responsibility

Safe disposal isn’t just about liability paperwork; it reflects respect for everyone outside the lab walls. Untreated phenol can poison water systems and kill aquatic life. By following hazardous waste protocols and using licensed chemical disposal vendors, we shrink our environmental impact. Some labs invest in phenol recovery or neutralization systems—an upfront cost that pays back in long-term environmental safety.

Real change starts with ownership. Treat each bottle of phenol as if your own hands, eyes, and future depend on sharp protocols—because in the end, they do. Never assume the rules are just for someone else. Every researcher has a role in turning checklists into real safety, both for the workplace and for the world beyond its doors.

Is Tris-EDTA equilibrated phenol solution suitable for RNA and DNA extraction?

Ground Reality in the Lab

Walking into any molecular biology lab, finding a shelf lined with chemical bottles isn’t a surprise. Few catch the eye—or the nose—like phenol. For DNA and RNA extraction, phenol splits samples into two neat layers, letting you pull out what you need. People often ask about using Tris-EDTA equilibrated phenol for both nucleic acids. It’s a simple question with layers, just like the extraction itself.

What’s Really in the Bottle?

Tris-EDTA brings two heavy hitters to the party. Tris keeps the pH steady. EDTA locks down free magnesium and calcium, stopping enzymes that chew up DNA or RNA. Getting pH wrong can break apart what researchers work so hard to protect. Phenol must stay at the right pH: pH 7-8 favors DNA, pH closer to 4 leans toward RNA.

Balance changes everything. Phenol alone strips away protein, leaving DNA or RNA, but if the buffer’s wrong, one type slips away or degrades. Tris-EDTA ensures pH stability and security for nucleic acids. This pair doesn’t just work in theory—it works in the hands that pipette day after day.

Challenges that Still Show Up

Not every phenol bottle gets pre-mixed perfectly. Older reagents sometimes oxidize, getting a golden tinge that tells you it’s time to toss them. That’s experience talking—a fresh batch saves projects. On the practical side, opening a bottle of phenol still means dealing with toxic fumes, even after balancing with Tris-EDTA. Labs with good ventilation and careful training handle these problems, but risks stick around.

Another snag? Sometimes labs find leftovers from previous extractions—bits of protein or phenol that sneak into that final sample. This can throw off PCR, sequencing, or anything downstream. The difference between publishable results and confusion usually rests on careful pipetting, fresh chemicals, and steady hands.

So, Does It Work?

Ask researchers who get their hands dirty, and the answer is clear. Tris-EDTA equilibrated phenol gets the job done for both RNA and DNA extraction if you pick the right pH. PubMed’s full of results proving its reliability. Classical protocols grew up using this reagent, and experienced scientists still reach for it. They know that if the buffer’s right and the technique’s tight, their bands will show up on a gel, crisp and bright.

Mentors often stress one lesson: know your reagent’s shelf life and always double-check pH. Never trust a dusty old bottle—phenol spoils both results and reputations. Running a blank extraction, checking UV absorbance, or just sniffing for that telltale chemical tang helps avoid mistakes.

Moving Forward

Safer alternatives exist. Some researchers choose commercial kits for convenience, skipping the risk that comes with pure phenol. Troubleshooting time and stress drop, but cost rises. Each lab must balance tradition with safety and budget. Standard phenol/Tris-EDTA extractions stay respected for one simple reason—they work, and the results speak loudly where it matters.

What is the shelf life of Tris-EDTA equilibrated phenol solution?

Lab Benches and the Quiet Shelf Dilemma

Every molecular biology lab keeps a bottle of Tris-EDTA equilibrated phenol solution somewhere. It lives in dark glass, sealed tightly, marked with labels already dulled by gloves and splashes. This solution isn’t something anyone wants to handle more than they have to. It’s powerful, but it’s picky. Understanding how long this solution remains reliable isn’t just a lesson in lab housekeeping. It’s about getting dependable results and keeping people safe.

Why Tris-EDTA Phenol Fails Over Time

Phenol stands up as a gold standard for nucleic acid extraction. Still, it comes with baggage. Light, warmth, and oxygen all chip away at its integrity. Over time, phenol oxidizes to produce quinones—nasty, deeply irritating compounds that turn clear phenol pink or red. These byproducts don’t just look ugly; they chew up DNA and RNA. Labs that miss these early signs could lose critical samples or even compromise published results.

What the Science Community Has Seen

Studies and lab manuals often point to a usable shelf life of about 6 months for phenol-Tris-EDTA solution, even when stored right. That means inside a dark bottle, at 2-8°C, shielded from light and tight from the air. These conditions slow down, but don’t stop, the march to quinone formation. Some researchers push their luck with older bottles, but risk rises. The odds of failure start to creep up, especially if the solution starts to smell sour or shift in color. Dr. Sambrook—which nearly every bench scientist has read—stresses checking color before use. If you spot that pinkish tinge, it’s time to toss it. No need to save a few bucks if it costs credibility or safety.

Health Concerns: No Luxury for Carelessness

Phenol isn’t just tricky for experiments; it’s hazardous for humans. Accidental spills can burn through gloves and skin and harm lungs if volatilized. The older the solution, the more unpredictable the hazard profile becomes. Quinones raise toxicity, and the breakdown can create volatile organic compounds, which make fume hoods a necessity. That tinge of pink isn't just a sign for reagent stability—it’s a warning sign for personal safety, too.

Signs the Solution’s Outlived Its Welcome

Relying just on a calendar doesn’t cut it. Good labs combine date tracking with regular, simple checks. Clear phenol with no odor, kept cold, likely works for up to six months. Anything else—hazy appearance, change in color, or a sharp, acrid smell—warns against continued use. Some labs keep pH strips around since a drop in pH can also clue scientists in to spoilage.

Managing Uncertainty on the Bench

One practical move comes from splitting bulk stocks into small aliquots. This way, only one small portion faces repeated temperature shifts and risk of oxidation. If an aliquot spoils, you only lose a week’s supply, not the entire batch. Logging the prep date on each bottle keeps everyone in the loop—not just the one who made it, but their whole team.

Some scientists switched to stabilized commercial preparations, which cost a bit more but reduce the questions about shelf life. These stabilized versions do what in-house prep can’t: They add a level of consistency and safety. For labs under heavy publication pressure, or those working with hard-to-replace samples, this option has proven popular.

Takeaway from the Trenches

Years on the bench taught me that the cost of integrity trumps saving a few bucks by using questionable reagents. No headline result is worth staking on an old bottle of phenol. Take care with storage. Split into aliquots. Check the solution before every use. Everyone wins—your samples, your data, and your fingers.

Tris-EDTA Equilibrated Phenol Solution
Names
Preferred IUPAC name 2-amino-2-(hydroxymethyl)propane-1,3-diol; 2-[bis(carboxymethyl)amino]acetic acid; phenol
Other names RNase-free phenol
Tris-equilibrated phenol
Phenol, Tris-EDTA buffered
Pronunciation /ˈtrɪs iːˈdiːˈeɪtiː ɪˈkwɪlɪbreɪtɪd ˈfiːnɒl səˈluːʃən/
Identifiers
CAS Number 8049-93-4
Beilstein Reference 2848763
ChEBI CHEBI:17716
ChEMBL CHEMBL1356
ChemSpider 24176241
DrugBank DB11118
ECHA InfoCard 30e22f99-bee5-4188-b58a-bc2d8f91493a
EC Number 200-573-9
Gmelin Reference 107187
KEGG C06001
MeSH D010673
PubChem CID 16211216
RTECS number SJ3325000
UNII Z71YUL964R
UN number 2810
CompTox Dashboard (EPA) DTXSID9086523
Properties
Chemical formula C6H5OH
Appearance Light yellow liquid
Odor Acrid
Density 1.09 g/cm³
Solubility in water soluble
log P 2.47
Vapor pressure 17.5 mmHg (25°C)
Acidity (pKa) 7.9
Basicity (pKb) pKb: 9.8
Magnetic susceptibility (χ) -7.2 × 10⁻⁶
Refractive index (nD) 1.517
Viscosity Viscous liquid
Pharmacology
ATC code V03AZ01
Hazards
Main hazards Toxic if swallowed, causes burns, harmful by inhalation, risk of serious damage to eyes, may cause skin sensitization.
GHS labelling GHS02, GHS05, GHS06, GHS07, GHS08
Pictograms GHS06,GHS05
Signal word Warning
Hazard statements H300 + H310 + H330: Fatal if swallowed, in contact with skin or if inhaled.
Precautionary statements P210, P260, P261, P264, P270, P271, P273, P280, P284, P301+P310, P302+P352, P304+P340, P305+P351+P338, P308+P311, P311, P312, P321, P330, P337+P313, P340, P342+P311, P352, P362+P364, P403+P233, P405, P501
Flash point > 110°C
Lethal dose or concentration LD50 (oral, rat): 317 mg/kg
LD50 (median dose) LD50 (median dose): Oral rat LD50: 317 mg/kg
NIOSH Not Listed
PEL (Permissible) Not established
REL (Recommended) 24 months
IDLH (Immediate danger) Not established
Related compounds
Related compounds Phenol
Chloroform
Isoamyl alcohol
Tris buffer
EDTA solution
Phenol:Chloroform:Isoamyl Alcohol mixture