Ficoll-Paque Plus: A Cornerstone of Modern Cellular Separation

Historical Development

In the early 1960s, researchers began striving for a reliable way to separate blood components, especially when investigating the immune system or treating disease. Before Ficoll-Paque, cell separation often relied on crude sedimentation or laborious filtration methods, which left plenty of room for contamination and inconsistent results. The Andersson and his team at Pharmacia developed Ficoll as a synthetic polymer partnered with sodium diatrizoate, creating a medium that allowed scientists to isolate cells with an ease that revolutionized immunology and hematology. Ficoll-Paque Plus, an improved formulation, reduced density gradients’ toxicity and offered a standardized approach for labs around the world. Every time I open a clinical journal from the 1970s onward, the name shows up where clean, reliable separation mattered most—paving the way for safe blood transfusions, stem cell research, and advanced diagnostics.

Product Overview

Ficoll-Paque Plus stands out as a ready-to-use solution for isolating blood mononuclear cells. It relies on a specific density gradient—carefully calculated so that, after centrifugation, lymphocytes and monocytes settle at a discreet interface. Manufacturers tweak the formulation by adjusting the balance between Ficoll polymer and the contrasting agent. This balance ensures that cells experience minimal stress and remain viable for downstream experiments or clinical applications. I’ve seen countless samples handled with Ficoll-Paque, with laboratories trusting its consistency whether working with fresh or anticoagulated blood. The product’s reliability comes from extensive validation and continued monitoring of lot-to-lot reproducibility.

Physical & Chemical Properties

The solution appears clear, nearly colorless, with a gentle viscosity that signals the strength of its colloidal structure. Ficoll, a hydrophilic high-molecular-weight polysucrose, creates a smooth density gradient during centrifugation. Mixed with sodium diatrizoate, the solution’s density clocks in at around 1.077 g/mL at room temperature, a sweet spot for separating out peripheral blood mononuclear cells. The neutral pH, typically set near 7.4, preserves cell health. Ficoll-Paque Plus doesn’t show notable reactivity with biological membranes, a fact that scientists count on for stable, repeatable results. The physical profile has allowed countless labs to trust this solution for their cell isolation routines.

Technical Specifications & Labeling

Most bottles of Ficoll-Paque Plus carry a clear label showing batch number, expiration date, storage instructions, and composition details. Storage at 4–30°C preserves its properties over a lengthy shelf life, usually two years. Technical data sheets accompany each unit, breaking down sterility assurances, endotoxin levels (below 0.25 EU/mL), and regulatory compliance per ISO and FDA standards. Each lot typically undergoes functional testing, confirming its efficacy in producing high-yield, high-viability lymphocytes or monocytes, which a scientist can verify in their own work by simple microscopy and trypan blue exclusion. These standards let professionals cross-check and assure quality, limiting the guesswork in their protocols.

Preparation Method

While the solution arrives pre-formulated, the preparation of samples for separation still requires a careful touch. Blood or bone marrow samples get diluted with physiological saline, then gently layered onto the Ficoll-Paque Plus medium in a conical tube. Centrifugation, typically at 400–500 x g for 30–40 minutes at room temperature, drives separation. A distinct white layer forms at the interface between the medium and plasma—the coveted mononuclear cells. Any errors at this step, whether through rough handling or improper centrifugation, can lead to contamination or lower yield. Experienced technicians develop a feel for the pipetting speed and angle, understanding that patience and attention to detail drive cleaner separation and ultimately more reliable data.

Chemical Reactions & Modifications

Ficoll-Paque Plus resists significant chemical breakdown during standard cell separation processes. Its primary reactions revolve around hydration, interaction with salts, and maintaining iso-osmolar conditions. Modifications target changing the density for specific cell types or adding buffers to support particular downstream assays. Some advanced laboratories have experimented with adding small molecule inhibitors to the gradient to preserve rare subpopulations or prevent unwanted activation during separation, but these modifications remain on the cutting edge, often proprietary. I’ve spoken to researchers who custom-mix gradients for stem cell enrichment, crediting the base properties of Ficoll-Paque for consistently delivering stable backgrounds for more tailored reagents.

Synonyms & Product Names

Beyond Ficoll-Paque Plus, one might find synonymous terms like Ficoll-Hypaque, Ficoll-Paque PREMIUM, or various catalog numbers such as GE Healthcare 17-1440-03. Ficoll variants from other brands, including Sigma’s Ficoll 400 or Lymphoprep, promise similar functions but often differ subtly in osmolarity or viscosity. The core components—Ficoll and sodium diatrizoate—remain consistent themes. Some papers use terms like “lymphocyte separation medium” or “gradient separation medium,” but real-world lab conversations still circle back to the Ficoll name given its legacy and reliability.

Safety & Operational Standards

Laboratories handling Ficoll-Paque Plus operate under strict biological safety protocols. Eye protection, gloves, and standard lab coats protect from accidental splashes, although the material hazard ranks as low. Still, sodium diatrizoate, while safer than many reagents, carries mild risk of irritation or allergic reaction in sensitive individuals. Routine use calls for designated workspaces, spill containment, and prompt cleanup. Waste disposal follows local chemical regulations, avoiding drains to prevent environmental impact. Facilities keep safety data sheets on hand, and new technicians receive direct training, which ensures safe and responsible handling on each shift.

Application Area

Over decades of observation, Ficoll-Paque Plus appears everywhere in basic science, clinical research, and diagnostics. Immunologists trust it for preparing lymphocytes from whole blood, fueling work on autoimmunity or vaccine development. Hematologists lean on it for bone marrow processing, especially in stem cell transplantation. Outpatient labs depend on it for preparing samples for flow cytometry. Most pivotal, clinical researchers have used it to separate circulating tumor cells, providing crucial insights in cancer surveillance. Blood banks employ Ficoll-Paque Plus in donor testing and infectious disease monitoring, giving healthcare teams the pure mononuclear fractions needed for further analysis or therapy. No other solution matches its versatility and success over such a wide span of scientific endeavors.

Research & Development

Advancement in gradient separation solutions owes much to ongoing feedback from laboratories worldwide. Manufacturers refine Ficoll-Paque Plus by reducing impurities, improving lot consistency, and adapting packaging to lab workflows. Recent years brought forth pre-filled tubes and innovative automation readiness, making set-up both quicker and less error-prone. Researchers drive demand for new densities or additives to expand the scope beyond standard lymphocyte isolation, such as using modified gradients for microvesicle recovery or rare cell capture. This feedback loop has cemented Ficoll-Paque’s role as both a market leader and a foundation for next-generation separation products. I remember touring a biotech facility and seeing first-hand the impact of R&D—production lines constantly honed to keep pace with shifting research needs and regulatory standards.

Toxicity Research

Early safety testing showed Ficoll-Paque’s components to be minimally toxic in routine concentrations. Inhalation and ingestion risks remain low, but repeated or high-dose exposure in animal models prompts some concern for osmotic imbalance or kidney burden due to diatrizoate. Current studies confirm that standard laboratory handling, combined with appropriate disposal, presents little hazard. Human cell viability studies repeatedly demonstrate high recovery rates without cytotoxicity, explaining the product’s widespread clinical and research use. Chronic exposure studies remain rare, but ongoing monitoring and updated safety protocols ensure worker protection with each batch handled. Those who work with immunocompromised patients often value the clean safety record, minimizing the risk for staff and research participants alike.

Future Prospects

Ficoll-Paque Plus looks set for another decade of relevance in laboratory medicine. The next generation of gradient solutions will likely deliver enhanced specificity for rare cell types or integrate digital tracking for quality control. Automated platforms may further reduce human error, while environmentally sustainable packaging and safer disposal options will answer public health and environmental demands. Emerging fields like single-cell genomics and personalized therapy will drive further tweaks in composition or protocol. During conversations with young scientists, I sense growing interest in even faster, less resource-intensive separation methods, but nearly all expect to rely on the precision and trust conferred by Ficoll-Paque Plus for the foreseeable future. Evolution in cell biology simply wouldn’t track as rapidly without these reliable gradients as the backbone of sample preparation.




What is Ficoll-Paque Plus and what is it used for?

The Backbone of Cell Separation

Ficoll-Paque Plus stands out as a workhorse in the toolkit of most biomedical researchers. Walking into any cell biology lab, you’ll likely spot bottles of this clear, slightly viscous liquid. The real question isn’t just what it is, but why it became so valuable for isolating living cells. Ficoll-Paque Plus contains Ficoll, a synthetic polymer, and sodium diatrizoate, a compound that sets the density just right for splitting up blood into its key components. Once I started using it during clinical lab rotations, my understanding of how research drives medicine took on a practical angle.

Getting Blood to Reveal Its Secrets

Every time a researcher draws a tube of blood, they see a chaotic mixture—red cells, white cells, platelets, plasma—all swirling together. What Ficoll-Paque Plus does is bring order to that mess. When you layer blood over Ficoll-Paque Plus and spin it in a centrifuge, something remarkable happens. The density barrier separates heavier red blood cells and granulocytes, sending them to the bottom. Meanwhile, lighter peripheral blood mononuclear cells (PBMCs)—lymphocytes and monocytes—float gently at the interface. I’ve run this process dozens of times, always surprised at that milky band resting between layers. This is where immune studies start, cancer tests begin, and future therapies take shape.

The Role in Research and Medicine

Ficoll-Paque Plus supports research into diseases from HIV to cancer, and autoimmune disorders. Scientists rely on these purified immune cells for everything from genetic analysis to vaccine research. I remember prepping PBMCs in cancer studies, knowing the results might help fine-tune treatments or even unlock new ones. The cleaner the cells, the fewer confounding variables sneak into the data. Ficoll-Paque Plus gives more reproducible results, a must-have in any study where accuracy drives decisions.

During the COVID-19 pandemic, the need for high-quality human cells exploded. Labs started banking PBMCs as fast as possible to learn about immune responses. Ficoll-Paque Plus helped deliver reliable results fast, supporting urgent questions nobody could afford to get wrong. As someone who has trained new researchers, I always push careful pipetting and timing. Even small slip-ups could eat into the precious PBMC layer and waste samples that took days to collect.

Refining the Process, Tackling the Challenges

No tool is perfect. Ficoll-Paque Plus works best with fresh blood, which means a race against the clock. Cells lose quality after sitting out too long. The dense, sticky liquid can get tricky to handle, clogging pipettes or stalling separation if not used with care. Some researchers try cheaper substitutes or tweaked mixtures, but batch consistency always drags them back to Ficoll–Paque Plus for critical work.

Automation and improved cell handling could smooth out bottlenecks, making it easier to process batches for biobanking or clinical trials. Training remains key—simple mistakes still crop up. Experienced hands make the difference, especially in crowded labs juggling many experiments at once. Investment into more user-friendly, stable gradient media might one day offer a good alternative, but nothing else seems to match Ficoll-Paque Plus for purity right now.

Why This Matters

The real measure of Ficoll-Paque Plus shows up far from the lab bench. The discoveries and therapies built on those quietly isolated cells drive life-changing treatments, guide diagnosis, and deepen our understanding of human biology. From first-year students to seasoned scientists, everyone in research feels the weight of getting each blood sample right. Ficoll-Paque Plus stays central—a reliable bridge between blood donor and tomorrow’s breakthrough.

How do you use Ficoll-Paque Plus for isolating mononuclear cells?

Why This Method Matters to Everyday Science

Anyone who has stepped into an immunology lab has probably heard of Ficoll-Paque Plus. It’s a familiar bottle, but the contents do more than separate blood; they unlock what we know about diseases and immunity. Getting consistent, reliable mononuclear cells allows for experiments that actually speak to real biological questions. With chronic illnesses growing and immune research taking center stage, clear, usable technique isn’t just lab routine—it goes straight for results people can trust.

Getting Practical: Step-by-Step Isn’t Just for Manuals

Working with Ficoll-Paque Plus starts way before blood hits a tube. For me, it always began with double-checking that the sample stayed fresh. Older blood already leads to fewer viable cells. Drawing whole blood into anticoagulant tubes, gently inverting (not shaking) sets the tone—no shortcuts for speed, as cell clumping ruins everything.

Next, pipetting blood on top of Ficoll-Paque calls for steady hands. The interface makes all the difference. I remember my first time—wasn’t as simple as the protocol made it sound. Tilting the tube or letting droplets fall too fast can mix the gradient, and you end up wasting reagents and time. Using a pipette with a thin tip and slow, patient layering prevents a botched interface. That clear separation means cleaner mononuclear bands later.

After centrifugation, the magic happens: neat layers. Red blood cells stay under the Ficoll-Paque, plasma floats above, and that cloud-like ring in the middle holds the mononuclear cells. Skimming this layer is where attention pays off. Taking too much of the Ficoll with the cells, or pulling up neutrophils by accident, muddies the sample. Years back, I made this mistake more than once—led to activated, useless cells and failed experiments.

Critical Details Often Overlooked

Cell recovery drops fast under the wrong spin speed or time, so reading the manufacturer’s specs every time still matters. Using the right brake settings on the centrifuge protects the separation. Harsh stops mix layers, soft stops keep each population where it belongs.

After harvesting, washing cells several times with a buffered saline removes residual Ficoll and platelets. Failing to do this can cause unexpected activation in assays, and those errors will surface days later when culture results just look odd. A little patience beats repeating expensive steps.

Supporting Claims with Evidence and Reflections

A lot of published immunology data owes its clarity to good Ficoll-Paque technique. Poor separation affects not just the purity but the actual behavior of the cells downstream. For example, studies highlighted in Nature Immunology point out that even trace red cell contamination skews T cell function. Having worked on vaccine research, I saw firsthand that cleaner PBMCs led to reproducible ELISPOT or flow cytometry data.

The Bigger Picture and Solutions for Common Pitfalls

Teaching new lab members always reminded me: good habits now save tomorrow’s data. Making sure everyone knows to prep tubes, label carefully, and never rush the layering process keeps waste down and quality up. Automation has started to emerge, but most labs still use manual separation. Investing in pipette training and regular technique checks gives a better return than buying another bottle of Ficoll-Paque after mistakes pile up.

By focusing on careful, methodical preparation, science gets closer to data that makes a difference. Ficoll-Paque Plus isn’t just a solution for separating cells—used right, it protects the investment in every blood draw and every experiment that follows.

What is the density of Ficoll-Paque Plus?

Setting the Record Straight on Density

Ficoll-Paque Plus has a density of 1.077 g/mL. You’ll find this number in every lab protocol that handles separation of human blood cells. It sounds technical and maybe a little trivial—until you’re the one pipetting in the lab. This density isn’t just some number passed around on data sheets. The entire success of isolating lymphocytes from blood hangs on it.

The Real World in the Lab

The first time I used Ficoll-Paque Plus, I learned the hard way what happens if you mess up your layers. Blood over Ficoll, gentle pipette, then centrifuge. If you try to get creative and shake the tube or add Ficoll at the wrong density, the “buffy coat” disappears or you end up with a mixed mess. There’s no shortcut. With 1.077 g/mL, red and dead cells sink, while your precious peripheral blood mononuclear cells ride on top of the clear interface like lifejackets. Take away that sweet spot, the whole thing falls apart.

Blood Separation Depends on More than Just Math

Density matters, but real blood isn’t textbook-perfect. People eat, drink, have health conditions—all of this skews cell densities. Ficoll-Paque Plus works because its specific gravity matches that delicate tipping point. Its synthetic composition makes it stable over time, compared to old sugar gradients. Even after years, I haven’t seen anyone ditch it unless they’re running on a shoestring or handling special samples like cord blood, where density has to shift a bit for different cell types.

Trusting the Data

I’ve seen the same number repeated in research papers, manufacturer protocols, and regulatory filings. Trusted manufacturers like Cytiva publish exact numbers for every batch. Peer-reviewed studies, including those in Nature Methods and Blood, rely on the same chemistry. Down the line, clinicians and researchers trust that an isolated cell population hasn’t been contaminated by a botched separation. This is real evidence, checked by experts and backed up by years of peer review. Labs keep batches of Ficoll-Paque Plus for years, running QC samples to make sure the density is as promised. It’s not theory—there’s money, patient safety, and career credibility hanging on it.

Can We Do Better?

Labs now and then try cheaper substitutes, like homebrewed gradients or old-school Percoll. Consistency drops, recoveries vary, sometimes with disastrous results. Ficoll-Paque Plus costs more per milliliter, but the reliability saves time and errors. If people want a more affordable solution, it means more effort in validation. Better tools for measuring exact densities at the bench would go a long way—not every research group can buy expensive density meters. Opening more global supply chains helps drop prices without sacrificing quality. Some say switching to closed, automated separation systems can cut out human error, but the core density needs to be nailed down first.

Why This All Stays Relevant

I remember one immunology project riding on pure cell populations for flow cytometry. The entire dataset and weeks of work would have crashed without a reliable separation step. Ficoll-Paque Plus and its density of 1.077 g/mL helped keep it on track. In research, tiny numbers on technical sheets transform into critical building blocks. Trustworthy materials make all the difference in outcomes for both experiments and patients.

How should Ficoll-Paque Plus be stored?

Unlocking the Importance of Storage for Lab Reagents

Between years spent in cell labs and watching research budgets get pinched, I’ve seen plenty of reagents wasted from simple storage mistakes. Ficoll-Paque Plus, popular for isolating lymphocytes and other cells, doesn’t tolerate careless storage. Shelf life, separation quality, even safety, sit on top of basic handling and storage.

What Does Ficoll-Paque Plus Need?

At its core, Ficoll-Paque Plus remains a dense, viscous liquid. It blends synthetic polymer Ficoll with sodium diatrizoate. Both show some sensitivity to temperature shifts and light exposure. Reckless storage – even for a couple of days – can toss off gradients and lead to cell clumping, visible precipitation, or untrustworthy results.

Sigma-Aldrich, GE Healthcare, and peer-reviewed method sheets all say it straight: 4°C to 30°C works for unopened bottles. Refrigeration tends to slow degradation, yet extreme cold, like a -20°C freezer, brings its own problems. Storage below freezing leads to irreversible phase separation or even bottle cracking. Labmates paying attention stash these on a middle shelf in the fridge, away from any freezing coils, where accidental frost never hits them. Forgetting a bottle on an open bench, then relying on it for PBMC separation, often just ends with wasted samples and an apologetic email to a supervisor.

Keep It Dark, Keep It Sealed

Light, especially UV, can degrade diatrizoate. Most suppliers use amber bottles for a reason. Once opened, any bottle should return to its original container and always seal tight. Evaporation changes the concentration and viscosity, and air exposure can let in unseen dust or microbes. Pouring Ficoll-Paque into smaller containers can make contamination more likely, so think twice before splitting a bottle unless a sterile hood stands ready. Date your bottles at opening – I ran into a case once where a colleague used three-year-old reagent because the date faded from the cap. The experiment failed, wasting two weeks of animals and reagents.

Spotting Trouble Early

Certain habits pay off in the long run. Check for cloudiness or floating stuff in the bottle before use. Ficoll-Paque Plus should look clear and light golden. Crystals, haze, or dried clumps mean toss it. Don’t risk the next blood draw or precious clinical sample. Even in busy labs, temptations to stretch a bottle never reward you with good data.

Stretching Every Dollar: Shared Responsibility

Research runs on tight funding. Replacing Ficoll-Paque Plus doesn’t always get easy sign-off. Teams that set up storage protocols and label everything well save headaches. Leaving advisory signs on the shelf like “No Freezing” can help new students or rush-hour mishaps from ending badly. Encourage a culture where anyone can toss questionable reagents without blame – better this than failing the next step in a grant-funded experiment. Tracking lot numbers and storage dates also helps later on, especially if a batch recall surfaces or journal reviewers request method proofs.

Why Bother?

Proper storage isn’t just a check-box. It protects your data, speeds up troubleshooting, and saves everybody money. Labs that build habits around this set themselves up to succeed. No one remembers the hours lost salvaging bad cell preps, but everybody enjoys reliable, clean separations on the first try. In the long run, respect for your reagents is respect for your research.

Is Ficoll-Paque Plus sterile and ready to use?

Trust and Consistency in the Lab

Many researchers rely on Ficoll-Paque Plus for isolating lymphocytes and mononuclear cells. Every experiment rides on trust: trust in the reagents, trust in the process, and trust that no hidden contamination will upend weeks of planning. Ficoll-Paque Plus, sold pre-packed in bottles, comes as a clear solution. Manufacturers label it as sterile, ready to use straight from the bottle. This isn’t just marketing—this means you unpack the bottle, move it to your sterile bench, and pour. No autoclaving. No awkward filtration. No praying the protocol works out.

Why Sterility Isn’t Just a Buzzword

Anyone who’s spent time growing cells knows how quickly contamination can flip results on their head. Bacteria and fungi sneak in through the tiniest cracks. Using a verified sterile reagent reduces that risk. Ficoll-Paque Plus undergoes filtration—usually 0.2 microns—right before bottling and gets packaged in sterile, tamper-evident containers. Manufacturers regularly cite batch quality checks and post-sterilization integrity. For labs running with strict biosafety requirements, this background means one less variable to fret over.

Ready-to-Use: More Than Just Convenience

People sometimes shrug off “ready to use” as a convenience phrase. In busy research settings, it means you save real time and avoid fiddly prep that could lead to mistakes. This package goes straight into cell separation protocols—density gradient centrifugation, for example—without dilution or filtration. Standardization keeps results consistent. In my own lab days, this ready-form was a lifesaver when splitting urgent blood samples or running time-sensitive immune assays.

It Pays to Read the Fine Print

Of course, even when companies back their claims, it’s worth browsing the product datasheets and technical sheets. Not every bottle lingers forever. Once opened, standard aseptic technique is crucial. Lid left off the bottle? Use compromised. The “sterile and ready to use” label means exactly that: the bottle, unspoiled, is clean and fit for immediate application in protocols demanding asepsis. Mishandling wipes away that advantage. Shelf-life matters as well. Temperatures climb, sterility could slip. Keep it at the recommended 2-25°C. Don’t freeze. Check the expiry date. These details keep the promises made on the label standing strong in the lab.

A Question of Reliability and Biosecurity

Regulatory bodies and journal reviewers both look closely at controls. Labs chase traceability, and Ficoll-Paque Plus offers lot numbers, clear trace records, and certificates of analysis. Remember, the source of all downstream data depends on the trustworthiness of what goes into the tube. Documenting the sterility and batch of Ficoll-Paque Plus used in a protocol smooths regulatory reviews and fights off doubt during peer review. It isn’t just about ticking boxes. It’s about matching good science with reproducible practices.

If You Hit a Sterility Snag

Accidents do happen. You spot any cloudiness, odd smell, or visible debris in your Ficoll-Paque Plus, pitch the bottle. Risking a contaminated sample isn’t worth a ruined experiment or endangering a clean cell line. In a pinch, freshly purchased bottles from reputable suppliers backed by certificates offer reassurance. User training matters too. Teach new lab mates to crack fresh bottles by the bench, never on a cluttered table, and recap tightly after every use.

Keeping Science Moving Forward

The fine margins separating success from failure in cell isolation come down to details like sterility and readiness. Ficoll-Paque Plus earns its place on lab shelves by giving researchers a reliable, contamination-free starting point. In busy, high-stakes labs, these basics drive reproducibility, keep research credible, and protect time and resources.

Ficoll-Paque Plus
Names
Preferred IUPAC name Polysucrose
Other names Ficoll-Paque
Ficoll-Paque PLUS
Ficoll Paque
Ficoll™ PLUS
Pronunciation /ˈfaɪ.kɒl ˈpɑːk plʌs/
Identifiers
CAS Number 144371-20-8
Beilstein Reference 3993086
ChEBI CHEBI:60739
ChEMBL CHEMBL1201473
ChemSpider 2157
DrugBank DB11114
ECHA InfoCard echa-infoCard-100000123043
EC Number 232-940-4
Gmelin Reference 31737
KEGG C02360
MeSH Polysaccharides
PubChem CID 71680236
RTECS number MN0286000
UNII G8L47MYI1M
UN number UN3142
CompTox Dashboard (EPA) CompTox Dashboard (EPA) of product 'Ficoll-Paque Plus': "DTXSID2035099
Properties
Chemical formula C6H12O6
Molar mass 300000 g/mol
Appearance Colorless to pale yellow liquid
Odor Odorless
Density 1.077 g/mL
Solubility in water Soluble in water
log P 5.4
Vapor pressure Negligible
Acidity (pKa) 7.0
Basicity (pKb) 10.3
Magnetic susceptibility (χ) unknown
Refractive index (nD) 1.370–1.380
Viscosity 1.4–1.6 mPa·s
Pharmacology
ATC code V04CX
Hazards
Main hazards May cause cancer; causes damage to organs through prolonged or repeated exposure
GHS labelling GHS labelling: Signal word: Warning; Hazard statements: H315, H319, H335; Pictograms: GHS07
Pictograms GHS07
Signal word Warning
Hazard statements H317: May cause an allergic skin reaction.
Precautionary statements Precautionary statements: P281 Use personal protective equipment as required. P308+P313 IF exposed or concerned: Get medical advice/attention.
NFPA 704 (fire diamond) 1-2-0-ox
Flash point > 93°C (199°F)
LD50 (median dose) > LD50 (oral, rat): > 5000 mg/kg
PEL (Permissible) not established
REL (Recommended) 1.077 g/mL
Related compounds
Related compounds Ficoll
Ficoll-Paque
Ficoll-Paque PREMIUM
Ficoll-Paque PREMIUM 1.073
Ficoll-Paque PREMIUM 1.084
Ficoll-Paque PREMIUM 1.090
Ficoll-Paque PREMIUM 1.100
Ficoll-Paque PREMIUM EDTA
Ficoll-Paque Hypaque
Percoll