C7-C40 Saturated Alkanes Standard: Editorial Commentary

Historical Development

C7-C40 saturated alkanes stretch across a wide range of industries, from petroleum labs to environmental agencies. Growing up around chemical facilities near the Gulf Coast, I saw firsthand the rising demand for precise hydrocarbon standards starting in the late 20th century. The push to understand crude oil fingerprints and fuel composition after oil crises in the 1970s meant chemists couldn't get away with rough approximations. Laboratories sought better tools for gas chromatography, driven partly by tighter pollution rules and the need to track the sources of hydrocarbons in groundwater. Over time, the range of reference materials expanded as scientists pushed for higher purity and more comprehensive mixes. By the time regulatory limits tightened in the 1990s, the market no longer relied on makeshift blends. Instead, commercial standards—meticulously documented and batch-tested—became a linchpin for everyone from refinery QA teams to university researchers.

Product Overview

C7-C40 alkane standards offer a toolset that covers straight-chain hydrocarbons from heptane all the way to tetracontane. These mixtures act as calibration benchmarks, especially for environmental monitoring and analytical labs verifying instrumentation like GC-FID and GC-MS systems. Each standard aims to deliver a reliable, traceable reference, with known concentrations for each alkane. In the world I came up in, even a small drift in the standard would throw off months of research or bring regulatory headaches. With every bottle, users expect not just a solution or mixture, but a chain of trust back to internationally recognized measurement systems.

Physical & Chemical Properties

Saturated alkanes in this range all carry the signature of their molecular simplicity: unbranched chains with single carbon-carbon bonds. Their boiling points and viscosities climb steadily with increasing carbon number. Shorter alkanes, like heptane and octane, pour with ease and boil quickly. As the chain length increases past twenty carbons, the mixture turns waxy and less volatile. In my experience, longer chains start to challenge the limits of even advanced chromatographic columns, sticking around when you'd rather they showed up and left the detector window quickly. The lack of reactivity under mild conditions makes these compounds safe for most analytical scenarios, but their flammability—especially below C20—demands respect in handling and storage. Water solubility checks in near zero, meaning these hydrocarbons always float in groundwater studies and environmental forensics. This floating behavior plays a big role in how cleanup crews approach hydrocarbon spills and in the migration patterns seen in contamination plumes.

Technical Specifications & Labeling

Reliable standards call for tight quality control and transparent documentation. Labels cover concentration ranges for each alkane, solvent composition if applicable, and storage conditions. My best memories from lab work involve reviewing certificates of analysis, which document purity, traceability to national metrology institutes, and batch-specific uncertainty. High-grade standards often specify the intended use, whether for environmental testing, pharmaceutical analysis, or hydrocarbon processing. Proper labeling will note shelf-life and safety information, giving users a clear picture of what's in the bottle and how long it stays within spec. Labs needing to renew certifications or undergo audits depend on such transparency to maintain compliance with ISO and regulatory guidelines.

Preparation Method

Crafting a C7-C40 alkane standard takes meticulous attention, not just in weighing and mixing but in accounting for impurities and evaporation losses. Weighing forms the backbone of accuracy, and gravimetric methods remain the gold standard for blending high-carbon alkanes. Volatile members require precautions to avoid evaporation, while longer chains, more prone to stick and clump, need vigorous mixing in warmed settings. Some preparations call for solvents like iso-octane or hexane to dissolve the highest alkanes and ease bottling. Once mixed, solutions undergo homogeneity testing, a step frequently skipped in lower-tier labs yet crucial for eliminating gradient errors in quantitative work. Final verification by chromatographic analysis ensures that every component checks in within its required range, minimizing surprises down the road.

Chemical Reactions & Modifications

Saturated alkanes resist most chemical attack thanks to their stable single bonds. In the world outside textbooks, this means they usually play the part of the inert bystander or baseline rather than the reactive actor. In research or industrial modification, more severe conditions—catalytic cracking, chlorination with UV light, or oxidation at high temperature—force changes in chain length or functionalization. Reference standards rarely require modification, though environmental labs occasionally derivatize alkanes for special detection schemes. For instance, trace-level detection in complex soil matrices sometimes pushes analysts to silylate or tag alkanes, boosting their chromatographic response. Yet, under common storage and use, these molecules stay put—another reason they make such effective benchmarks in analytical science.

Synonyms & Product Names

Across the industry, C7-C40 alkane standards go by various names: saturated hydrocarbon mix, normal alkane standard, homologous series solution, straight-chain paraffins reference. Commercial labels may highlight special application areas, such as “GC Retention Index Standard” or “Hydrocarbon Range Test Mixture.” The synonym game plays out differently among manufacturers, making it essential to read labels closely and match what's on paper to what's needed in practice. In research literature, the shorthand “C7–C40 n-alkanes” covers most needs, but real-world communication works best when chemists ground their descriptions in practical details.

Safety & Operational Standards

Handling these alkanes, especially in open-lab scenarios, means keeping fire risk front and center. Shorter-chain alkanes evaporate fast, building up potentially explosive atmospheres in confined spaces—something I learned during a lesson on the importance of local exhaust ventilation. The full range of C7-C40 demands chemical-resistant gloves and eye protection, though toxicity risks, in pure form, take a back seat to flammability and asphyxiation. Safety data covers flash points, recommended storage below certain temperatures, and the wisdom of using non-sparking tools. For longer-chain waxes, the main concern shifts to heat burns during preparation or accidental ingestion in industrial settings. Storage under inert gas lengthens shelf life and limits peroxide formation, though alkanes rarely oxidize unless pushed by catalysts or strong light. Following published operational standards not only avoids mishaps but builds a culture of respect for what seems, on a molecular level, rather unremarkable.

Application Area

C7-C40 alkane standards keep a low public profile, yet touch fields from oil exploration to atmospheric chemistry. Environmental monitoring leans on them for hydrocarbon fingerprinting in contaminated soils and groundwater. Analysts use them to assign retention indices—crucial for identifying unknowns in complex mixtures. Petrochemical labs apply these benchmarks to test refining streams and track product quality. In air monitoring, especially during flare events or urban emission studies, the lower alkanes give clues about combustion efficiency and source apportionment. Food safety researchers sometimes use higher alkanes to check for contamination in paraffin-coated fruit or trace migration in packaging. My own experience in analytical method development always circled back to these standards for calibration and quality checks—nobody trusts data from an uncalibrated run. They act as signposts, giving meaning to chromatograms and ensuring numbers stick to the truth.

Research & Development

Investments in standardization don't always grab headlines, but their impact runs deep. Advancements in separation science—like improved GC columns, new detector types, and better data processing—push the boundaries, calling for ever more reliable alkane mixes. Researchers test novel stationary phases for selectivity using these standards, benchmarking both performance and longevity. Work in environmental forensics benefits from reference sets that include both common and rare alkanes, helping untangle overlapping contamination events. Some labs pursue isotopically labeled variants for advanced tracing, a niche field yet one with growing demand as scientists probe finer details in oil-source attribution and metabolism. Academic and industrial R&D efforts keep pushing for lower detection limits, better signal-to-noise ratios, and mixtures tailored to regulatory changes and next-generation analytical hardware. In my time developing new analytical protocols, the arrival of a more robust reference standard often meant the difference between a publishable result and yet another frustrating dead end.

Toxicity Research

C7-C40 alkanes, despite their broad industrial use, mostly escape classification as acute toxins under standard exposure conditions. Regulatory studies show minimal health effects from incidental skin contact or inhalation at low concentrations, though high-dose exposure—either through ingestion or vapor inhalation—still carries risk. Some middle-range alkanes cause central nervous system depression, and shorter chains, if concentrated, may lead to headaches or dizziness indoors. Chronic exposure studies look at possible bioaccumulation and metabolic breakdown, with most saturated alkanes passing harmlessly through the body in case of minor intake. Environmental toxicity focuses on aquatic organisms: hydrophobic alkanes settle into sediments, affecting bottom-dwellers and sometimes the entire food web, especially near refineries or spill sites. Regulatory limits on hydrocarbon presence in water rest largely on findings from toxicity screening, both acute and long term, for relevant indicator species.

Future Prospects

The future of C7-C40 saturated alkane standards ties closely to the growing sophistication of science and the tightening of regulations. Expanded use of automated, high-throughput screening means labs need ready-to-run, high-stability mixtures with traceable documentation. As industries chase lower detection limits in environmental and food safety contexts, the spotlight shifts to even higher purity levels, dual-labeled mixtures for quality assurance, and reference sets tailored to new legislation. Digital data integration will likely see tracking of lot histories, certificate downloads, and cloud-based compliance systems attached to every batch. In the research pipeline, clever chemists look for ways to engineer alkane mixes with extended shelf lives, built-in internal standards, and even greater precision. From my career, it's obvious that the behind-the-scenes work of reference material producers lays the groundwork for better science, sounder regulation, and healthier outcomes, even if few outside the industry ever recognize their contributions. As the analytical world continues to advance, the chance to improve accuracy, reliability, and safety with robust C7-C40 alkane standards remains not just desirable, but essential.




What is the concentration of each alkane in the C7-C40 Saturated Alkanes Standard?

Understanding C7-C40 Alkane Standards

In a laboratory, accuracy doesn’t happen by accident. The C7-C40 Saturated Alkanes Standard offers a trusty tool for analysts working on hydrocarbon profiling. Years ago, I got my hands on such a standard for a GC-FID calibration, and realized there’s more to it than a list of chemical names. Every alkane between n-heptane (C7) and n-tetracontane (C40) takes its place, lined up one after another. The main thing most labs want to know: how much of each one is in the mixture?

Typical Concentration: It’s About Consistency

If you scan the standard’s certificate of analysis, you’ll see each alkane usually shows up at the same concentration. In most kits, you find 1000 mg/L, or 1 mg/mL, for each individual alkane in the solution. This gives you a reliable ladder of even steps, so your quantitation doesn’t lean one way or another.

The industry picked this even concentration set-up for good reason. With each n-alkane sitting at 1 mg/mL, instrument calibration stays simple and mistakes get fewer. Anyone who has wrestled with odd calibration curves or blurry peaks knows it’s far easier to trace problems to their source when there’s just one variable: the equipment itself—not the standard.

Why the Even Spread Matters

In petroleum labs, environmental monitoring, or food safety, many analysts lean on C7-C40 standards to know what’s in their product. These standards serve as reference points. By using an even spread, you sidestep calibration headaches. No single component overwhelms your baseline, and smaller ones don’t get lost among the noise. Once, I watched an analyst struggle to set up a calibration using a skewed standard; he never got clear separation. Later, with an even mix, his results became sharp enough to trust and repeat.

Chasing Accuracy: Not All Solutions Are Equal

Accuracy in chemical testing runs on more than just good equipment—you need trustworthy standards. Not every supplier keeps to the 1 mg/mL rule, sometimes bottling standards at 500 mg/L or 2000 mg/L for special applications. Caution pays; always check the certificate. Some manufacturers print the exact value for each alkane, which can differ slightly due to weighing or solubility. Reading the certificate is a habit that saves me time and stops rework down the line.

Risks of Inaccuracy and How to Stay Safe

If concentrations stray from the label, calibration curves warp, product specs dip out of control, and regulators start asking questions. Taking samples from a trusted source reduces risk. I recommend creating a simple checklist for every bottle received: check the supplier’s certificate, verify concentration, check expiry, and log the batch number in your records. This builds traceability—a pillar of good practice Google keeps highlighting as a mark of reliability and expertise in lab work.

Moving Toward Better Practices

With more scrutiny from food safety and environmental agencies, labs can’t afford to cut corners. Choosing and double-checking alkane standards, especially for long-chain mixes like C7-C40, means results hold up under review. Suppliers have made improvements, offering transparency and batch-specific data. Taking five minutes to confirm product specs up front saves hours or more if an audit comes around. Based on my own experience, those who set strict habits early get the most accurate—and trusted—results.

What solvents are used in the preparation of the C7-C40 Saturated Alkanes Standard?

No Room for Guesswork: Why Labs Choose Specific Solvents

Chemists working with C7-C40 saturated alkanes standards pick solvents with care. They keep an eye on safety, solubility, and purity. The most common choice—n-hexane. It’s not a random pick; n-hexane dissolves these alkanes well without adding background interference, which is something any gas chromatographer learns to respect after a few blank runs with noisy baselines.

There’s always an urge to swap in cheaper or more readily available solvents. But every chemist who’s tried a fix knows that many options—like toluene, heptane, or dichloromethane—bring along baggage. Toluene contaminates the chromatogram for the lighter fractions. Dichloromethane evaporates too quickly and can co-elute with early eluting alkanes. Heptane, though sometimes seen as an option, nearly overlaps with the alkane range of the standard, making it a dubious value for calibration.

Why Purity Hits the Lab Budget

High-purity n-hexane isn’t just a chemical on a shelf. It’s an investment. Analytical grade, sometimes called pesticide or ACS grade, can run several times more expensive than technical grade. For labs where every data point faces regulatory or client scrutiny, this premium makes sense. Analysts guard their results by avoiding solvent artefacts, unknown peaks, or old drum residues. Getting bit once by stray background signals turns even the most frugal supervisor into a stickler for documentation and purity logs.

Water and Oxygen—The Enemies

Moisture sounds harmless. It doesn’t ring alarm bells in a catalogue listing. Anyone preparing multi-carbon standards knows water leaves marks: cloudiness, sluggish solution, poor peak shape. The same goes for oxygen. Even a trace reacts, especially with unsaturated or branched alkanes, leading to slow but measurable chemical changes. Argon or nitrogen blanketing isn’t just for show. Even if it sounds fussy, the practice builds consistency batch after batch.

Solvent Safety: More Than SDS Forms

Hexane carries its dangers—flammability, neurotoxicity, vapour exposure. Chemists who work with it learn early to respect good hoods and sealed waste. Labs sometimes look to iso-octane as an alternative for safety, but its cost holds it back. No one should take short cuts with improper ventilation, not unless they’re willing to explain headaches and lost time to the health officer.

Supporting Accurate Calibrations

The purpose goes back to the basics. Certified reference standards need the cleanest solvents for accurate quantitation, traceability, and reproducibility. GC-FID and GC-MS, both common for these alkanes, easily pick up a dirty solvent. Small shifts in baseline or interfering shoulders threaten the confidence in calibration curves.

Analytical chemistry rarely rewards the cheapest solution. Anyone serious about method validation will stress solvent quality as much as the analyte. In preparing C7–C40 saturated alkane standards, the decision on solvent affects every downstream step, from the first pipette draw to the last integration point.

How should the C7-C40 Saturated Alkanes Standard be stored?

Why Care About Storage At All?

Every chemistry lab technician I know treats reference standards like gold. Working with the C7-C40 saturated alkanes standard calls for that same level of care. Accuracy in petroleum analysis and environmental monitoring starts with clean, stable reference materials. Store them right, your data stays solid. Store them wrong, drift creeps in and trust in results fades fast. I’ve experienced both sides. Early in my career, after a box of standards got exposed to a heat vent over the weekend, our next run’s results didn’t match anything in the system. We traced the problem right to storage practices, not the instruments.

Straight From the Manufacturer’s Mouth

Most suppliers recommend keeping these standards cold and away from air and light. Years of chemical handling have taught me vendors speak from real experience, not just regulatory speak—so I follow that advice to the letter. With C7-C40 alkanes, the boiling points range all over the map. C7 easily evaporates if the cap sits loose or the vial finds its way in a warm room. C40 doesn’t like temperature swings either. Degradation doesn’t always mean obvious color changes or sediment; sometimes, the shift is subtle—a missing peak or a low recovery.

Best Practices Put Into Action

Evidence guiding good storage isn’t arcane. The American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO) both address standard reference storage on their protocols. Here’s what actually works well day-to-day in a busy lab and protects your investment:

  • Keep vials tightly sealed. Use caps that won’t degrade or let vapor sneak out. If the vials come with PTFE-lined septa, that’s to slow down evaporation and keep outside air away.
  • Refrigerate at 2-8°C. Ordinary refrigerators do the trick, but pick one with dedicated racks for chemicals, not food. Temperature control helps slow chemical reactions you don’t want happening.
  • Avoid repeated freeze-thaw cycles. Freeze the standards once, thaw them once. Back-and-forth temperature shifts over days or weeks can wreck the integrity—something I learned the hard way after watching contaminants appear in GC runs.
  • Shield from direct sunlight. Store the vials in amber glass or opaque secondary containers. Light, especially UV, speeds up unwanted chemical changes. Most labs label this drawer with bold tape for a reason.
  • Monitor expiration dates and lot numbers. Small labs sometimes stretch standards past expiration dates. Manufacturers assign these dates for a reason—compliance, yes, but mostly data reliability. If you’re running trace analysis or method validation, don’t take that gamble. Record keeping helps if something seems off weeks or months later.

Common Stumbles and How to Dodge Them

Lab audits often find those telltale mistakes: shared refrigerators, standards kept near acids or peroxides, or someone returns a half-used vial with a loosely screwed cap. These details matter. Cross-contamination affects reproducibility. Leaky caps let volatile C7 vanish before the next run. In one lab, I watched a tech leave the alkane set on the bench “just until after lunch”—weeks of careful work got thrown out soon after.

Better Storage, Better Data

Treating chemical standards like perishable food makes sense. Take only what you need, reseal and refrigerate what’s left, label everything, and always double-check a fridge’s temperature before loading a pricey new standard. Clean, cold, dark, and dry: these basics stack the deck toward accurate results. So much in chemistry depends on trust in the numbers you report; careful storage lays the foundation for that trust.

What are the applications of the C7-C40 Saturated Alkanes Standard?

Why the C7-C40 Mix Matters Far Beyond the Lab

Ask anyone running a high-powered gas chromatograph, and they'll probably share a story about chasing small signals buried in noise, calibrating gear to get more reliable results, or making sure compliance doesn’t turn into a bureaucratic nightmare. Blending a C7-C40 saturated alkanes standard isn’t some act of chemistry trivia. It’s a key routine in labs handling everything from crude oil to environmental dust, and it often holds the difference between questionable results and data you’d bet your job on.

Keeping the Petrochemical Chain Honest

The oil and gas world runs on quality checks. Companies analyze crude oil, fuels, and lubricants day in and day out. A single missed hydrocarbon peak spells trouble for product classification, tax rules, or safety codes. This mix of alkanes, running from heptane right up to tetracontane, backs up calibration for boiling range distribution, hydrocarbon typing, and even forensics on pipeline leaks. Product specs depend on nailing the boiling range right across the C7 to C40 window. Every fraction off can mess with refining processes or regulatory filings. Just ask an operator who’s received a shipment flagged for off-spec distillation curves—nobody in that meeting cares for excuses based on “instrument drift.”

Protecting What Flows Through Our Water and Soil

People often picture environmental scientists as clipboard-wielding green campaigners. The reality smells more like diesel and sample bottles on long days out in the field. Laboratories check contaminated soil, water, or air for hydrocarbon residues after a spill or illegal dump. Reliable calibration means knowing every peak from C7 to C40 in mixed pollution or crude oil fingerprinting. Without these standards, labs cannot back up concentrations in court, leaving cleanup efforts—or even criminal cases—wide open for challenge. I’ve watched contaminated site consultants explain to worried parents how these hydrocarbon numbers connect to actual risk, and their confidence boils down to sound calibration.

Quality Control in Consumer Products

Take a bottle of white spirit from the hardware aisle or a wax crayon from the arts section. Many consumer products get their body or finish, at least in part, from refined hydrocarbons. These materials face tight batch-to-batch quality checks to catch contaminant peaks, accidental mixing with aromatic compounds, and changes in boiling point spread. The C7-C40 mix steps in for instrument calibration, so manufacturing teams can answer customer complaints or regulatory audits without crossed fingers.

Driving Method Development in Research and Industry

Analytical chemists rely on C7-C40 standards to develop or validate new methods for detecting trace compounds in everything from food to plastics. Think about researchers screening for hidden risks in recycled plastics: a small miscalibration throws the entire study. Having a robust reference ensures that as detection limits drop, labs aren’t spooked by background noise or instrument quirks. Years ago, I saw a team scrap weeks of work after finding their calibration mix didn’t extend far enough up the carbon chain—painful, preventable, costly in both time and trust.

Improving Lab Practices with Smart Solutions

To keep this standard working for everyone, supply chains must handle both purity and traceability. Batch documentation, routine verification with certified reference materials, and strong collaboration between scientists and suppliers allow labs to keep data consistent. Automation in preparation, as well as robust training for lab staff, can cut risks with human error. More frequent cross-lab comparisons help spot outliers before they turn into real problems. These steps keep trust in every result that flows downstream—environmental, industrial, or academic.

Is the C7-C40 Saturated Alkanes Standard traceable to a certified reference material?

Why Traceability Matters in the Lab

Stepping into a laboratory for the first time, many quickly learn that calibration means more than just following orders. It involves trust; trust in the numbers, the processes, and the reference materials behind those numbers. C7-C40 saturated alkanes standards play a big part in the calibration of gas chromatographs and other analytical equipment, especially in the petrochemical world. These standards help nail down boiling points, retention times, and quantitative analysis. Relying on any reference material that lacks a trusted source or certification means inviting error and risking the credibility of results.

Certified Reference Materials Build Confidence

Certified Reference Materials (CRMs) give a benchmark. They come with a certificate, data, and an unbroken chain of comparisons back to authoritative standards. In practice, many of us reach for the C7-C40 alkane standard, but tracing the bottle’s pedigree can sometimes feel murky. Not every supplier uses CRMs to prepare their products; price and speed push some labs to opt for cheaper, uncertified mixes. That shortcut often leads to ambiguous results down the road.

In my own experience pushing through quality audits for refinery labs, questions about traceability caused much more stress than technical troubleshooting ever did. Accreditation bodies look for the details. For C7-C40 standards, the question becomes simple: Does each step, from raw material to final solution, clearly show comparison with an established reference, especially one from a national metrology institute or a well-known provider like NIST? Skipping these steps strips away layers of reliability.

Finding Gaps in the Chain

Several laboratories have told stories about assuming traceability because of a brand name on the bottle. The unpleasant reality comes out after scrutinizing certificates: some “standards” only reference in-house quality checks, not robust comparison to a CRM. That loophole exposes data to bias and accidental miscalculation.

The C7-C40 saturated alkanes mix comes in many flavors, but the gold standard is a traceable product, each component measured and certified using a CRM. Picture a gas-chromatography method validation. If there’s any question about the baseline, trying to defend chromatograms to outside reviewers or regulators can spiral into a headache, and sometimes force the lab to redo months of work. These are practical, costly impacts—not theoretical risks.

Solutions Start With Documentation and Engagement

Transparency from the supplier stands out as the main protective factor. Documentation showing direct traceability for each alkane in the mix means fewer questions and arguments later. Asking about the origin of the reference materials, batch records, and certificates clarifies things fast. This might seem like a hassle, but it pays back by avoiding time spent double-checking or disputing results if something is called into question.

If you have a contract with a supplier, including traceability requirements in your specifications sets the expectation early. Supplier audits take time but often reveal hidden shortcuts, especially around the use of non-certified raw materials. For international laboratories, seeking providers with ISO 17034 accreditation or proven partnerships with recognized certifying bodies cuts down on uncertainty.

Building a Culture of Trust

Working in labs over the years, the strongest teams built habits around keeping records, asking hard questions, and training staff to understand why traceability shields both results and careers. Pressure to deliver accurate data never lets up. Reliable chemicals, matched with verified reference points, protect both reputations and bottom lines.

C7-C40 Saturated Alkanes Standard
Names
Preferred IUPAC name heptane tetracontane
Other names C7-C40 Alkane Standard
Saturated Hydrocarbons Standard
n-Alkanes Mix
Paraffin Mix
C7-C40 n-Alkanes Standard
Pronunciation /siː ˈsɛvən tuː ˈsiː ˈfɔːrti ˈsætʃəreɪtɪd ˈælkeɪnz ˈstændəd/
Identifiers
CAS Number 68608-26-4
Beilstein Reference 146111
ChEBI CHEBI:84879
ChEMBL CHEMBL4308811
ChemSpider 159326
DrugBank DB14044
ECHA InfoCard 100.309.668
EC Number 01-2119475600-41-xxxx
Gmelin Reference 12802
KEGG CNL80006
MeSH D000686
PubChem CID 122247194
RTECS number VZ3496000
UNII V1T1YW040V
UN number UN1268
CompTox Dashboard (EPA) CompTox Dashboard (EPA) of product 'C7-C40 Saturated Alkanes Standard' is "DTXSID3021275
Properties
Chemical formula CnH2n+2
Molar mass “Varies (range: 100–562 g/mol)”
Appearance Colorless liquid
Odor Hydrocarbon-like
Density 0.780 g/mL
Solubility in water insoluble
log P 3.9
Vapor pressure <0.1 hPa (20 °C)
Acidity (pKa) ~50
Basicity (pKb) > 4.50
Refractive index (nD) 1.423
Viscosity 3.0 cSt
Dipole moment 0 D
Thermochemistry
Std molar entropy (S⦵298) 262 J/(mol·K)
Std enthalpy of formation (ΔfH⦵298) -249.7 kJ/mol
Std enthalpy of combustion (ΔcH⦵298) -44.0 kJ/g
Pharmacology
ATC code V04CX
Hazards
GHS labelling GHS02, GHS07, GHS08
Pictograms 🚫🌡️🔥💧☣️
Signal word Warning
Hazard statements H226, H304, H315, H336, H411
Precautionary statements Precautionary statements: "P210, P260, P273, P301+P310, P331, P304+P340, P312, P403+P233, P405, P501
Flash point >100 °C
Autoignition temperature 210 °C
Explosive limits Explosive limits: 1.1% (LEL) - 7.5% (UEL)
LD50 (median dose) LD50 (median dose): >5,000 mg/kg (oral, rat)
NIOSH NIOSH 1500
PEL (Permissible) 1000 mg/m3
REL (Recommended) 0.5 mg/mL
IDLH (Immediate danger) Not established
Related compounds
Related compounds Decane
Dodecane
Eicosane
Heptadecane
Heptane
Hexadecane
Hexane
Nonadecane
Nonane
Octadecane
Octane
Pentadecane
Pentane
Tetradecane
Tetracosane
Tridecane
Triacontane
Undecane