Yudu County, Ganzhou, Jiangxi, China sales3@ar-reagent.com 3170906422@qq.com
Follow us:



1,10-Phenanthroline Hydrate Hydrochloride: A Cornerstone of Modern Chemical Research

Tracing Back Historical Roots

Bumping into a bottle of 1,10-Phenanthroline Hydrate Hydrochloride on a laboratory shelf, I think about the journey behind it. Chemists in the late nineteenth century didn’t have this compound on their radar. The earliest reports trace back to the painstaking work of synthesizing phenanthroline derivatives during a period of classic organic dye studies. Its roots anchor among those first efforts to understand chelation and aromatic ring manipulation — and it didn’t take long before this ligand started showing up in the footsteps of Nobel-winning discoveries, thanks to its strong affinity for transition metals.

Getting to Know the Substance

Crystals of 1,10-Phenanthroline Hydrate Hydrochloride often appear white to pale yellow, occasionally showing a glossy sheen under lab lights. In water, it dissolves smoothly, hinting at its use in all sorts of aqueous reactions, while its smell often doesn’t register — a welcomed trait in a world full of pungent solvents and acrid acids. Handling this compound, it feels powdery and tends to clump if the air humidity creeps too high, something every bench chemist contends with on rainy days. In terms of chemical structure, the nitrogen atoms in the rings are like open pincers, eager to grip tightly onto metal ions.

Physical & Chemical Properties

One striking feature of 1,10-Phenanthroline Hydrate Hydrochloride lies in its straightforward hygroscopicity, meaning it pulls water from the air, so you want to cap the bottle right after use. With the hydrochloride salt, it boasts better water solubility than its parent compound, which helps in analytical applications, especially as a delicate colorimetric reagent for iron. Its melting point and stability serve the average chemist well, both in solution and as a solid. The molecular backbone sits rigid, driven by aromatic stabilization and the precise positioning of the nitrogen atoms.

Technical Specifications and Labeling Realities

Labels on this reagent don’t just fill space. They give the CAS number, identify exact hydration state, and show purity percentage — not only for regulatory compliance, but so the bench chemist doesn't waste time second-guessing what’s in the bottle. Accurate information at a glance prevents simple lab mistakes that lead to hours of troubleshooting.

Preparation and What It Demands

Producing 1,10-Phenanthroline Hydrate Hydrochloride requires a series of delicate steps. Early chemists derived it from phenanthrene through oxidation and subsequent amination, a route that took patience and plenty of distillations. Now, the hydrochloride form emerges from direct hydrochloric acid treatment, a tidier and easier-to-reproduce synthesis. Controlling moisture proves essential, given this product's affinity for water. Chromatographic purification and recrystallization finish the job, locking in the purity that today’s research demands.

Versatility in Chemical Reactions

If you want to see chemistry in action, mix phenanthroline with an iron salt: bright red-orange colors tell you at once that the compound’s ready to form chelates. This reagent takes part in redox titration, analytical detection, and complexometric reactions, handling everything from transition metal quantification to spin-state switching in materials science. My own dives into catalysis demonstrated how robust phenanthroline-based ligands can perform in cross-coupling reactions, making them essential for synthetic organometallic chemists. Structural modifications, such as alkylating or sulfonating phenanthroline, broaden its chemical toolbox, without straying far from its core performance traits.

Alternative Names and Synonyms

There’s no shortage of names for this staple. 1,10-Phenanthroline Hydrochloride, o-Phenanthroline Hydrochloride, and phenanthroline monohydrate hydrochloride all show up in catalogs and research papers. No matter the moniker, it delivers the same reliable performance in test tubes and beakers worldwide.

Safety and What the Lab Demands

Cracking open a fresh bottle in research labs, I always check for hazard labels and review the available safety data sheets. Touching the compound with bare hands isn’t wise, though it doesn’t burn or sting like a corrosive acid. Inhaling powders poses a bigger concern, given their ability to disperse quickly and settle in the smallest crevices of lab benches or lungs. Gloves, masks, and good ventilation are non-negotiables. Its handling ingrains safe habits early for students stepping into the chemistry world, forming a foundation before moving on to more sinister hazards. Larger spills, while rare, call for wet wiping and conscientious disposal, keeping phenanthroline out of sinks and chemical drains. Strict adherence to Occupational Safety and Health Administration (OSHA) and laboratory guidelines protects today’s workforce from routine exposure.

Application Runs Deep

One of my first real experiments as a student relied on this compound for iron detection, and that experience is mirrored in labs around the globe. Water quality monitoring, environmental testing, forensic analysis, and industrial factories all tap into the powerful color shifts offered by phenanthroline-iron complexes. It acts as a platform for studying DNA cleavage by metal complexes, helping pharmaceutical researchers understand potential anticancer or antibacterial agents. Electrochemical sensors draw on its strong, selectivity-driven chelating action, giving rise to technology used in medical diagnostics and environmental fieldwork alike.

Research Takes Its Cues

Countless papers explore the electronic environment of 1,10-Phenanthroline and its derivatives. Breakthroughs in photochemical water splitting and visible-light emission from metal complexes wouldn't land in journals without these ligands. Chemists continually tweak its backbone to improve selectivity, binding strength, and redox properties — core skills for building next-generation catalysts and sensor dyes. In my own work with nanomaterials, 1,10-Phenanthroline-based compounds bridged the world between simple molecular sensors and functional nanodevices. It inevitably shows up in areas like metal-organic frameworks (MOFs), where fine-tuning ligand structure drives advances in gas storage and targeted drug delivery. Its use keeps stretching in new directions, in step with emerging materials and green chemistry.

A Close Look at Toxicity

No chemical can claim a spotless record, and extended toxicity trials reveal this compound's hazards. Acute oral, inhalation, and skin exposure studies show moderate toxicity markers — not as dramatic as heavy metals or strong alkalis, but not to be dismissed. Chronic exposure links to irritation and organ effects, sparking thorough investigation in regulatory toxicology circles. I take extra steps to minimize even small exposures, keeping in mind those seemingly minor contacts can add up over time. Proper training and ongoing research into less hazardous alternatives underscore responsible use, both for the people in the lab and the wider environment.

Shaping the Future

Looking ahead, 1,10-Phenanthroline Hydrate Hydrochloride isn’t fading into obscurity. Its structural adaptability fits the changing needs of catalysis, environmental sensing, and medicinal chemistry. As sustainable chemistry gets more attention, refinements in synthesis methods and waste reduction turn into priorities. Research focuses on greener production that skips harsh reagents and avoids metal contamination. Development of new hybrids and analogues built around the core scaffold continues at a strong pace, hinting at fresh breakthroughs in areas as diverse as optoelectronics and clean-energy systems. The compound's track record proves that simple structures can give rise to complex and meaningful progress, and ongoing efforts to optimize its safety and versatility make it a safe bet for continued relevance, both in the classroom and inside the most advanced research institutions.




What is the chemical formula of 1,10-Phenanthroline Hydrate Hydrochloride?

Breaking Down the Name

Talking about 1,10-Phenanthroline Hydrate Hydrochloride pulls us into a corner of chemistry where clarity matters. The core of this compound, 1,10-Phenanthroline, stands as a popular ligand in labs. I remember from my own undergraduate days that its structure—a planar system of three fused rings, with nitrogen atoms at the 1 and 10 positions—made it useful for binding metals like iron and copper. Throw in water of hydration and a hydrochloride salt, and the name stretches out, layer by layer, into precise chemical language.

The Formula Unpacked

Let’s slice this up. Pure 1,10-Phenanthroline is C12H8N2. The “hydrate” means at least one water molecule tags along for the ride, and in most reagent bottles, you’ll find it as the monohydrate: that adds H2O. Now for “hydrochloride,” which means one equivalent of hydrochloric acid has reacted with the base, protonating one of the nitrogen atoms and tacking on a chloride ion.

So, you add everything together. The formula for the monohydrate hydrochloride becomes C12H9N2Cl·H2O. Older catalog entries and some lab notes swap the dot for a plus sign, but the meaning holds. If you want to check this, think back to college chem—count your hydrogens, eye your ions, and you’ll see it adds up.

Why Details Matter in Science

I remember professors hammering home the point that a tiny slip in the formula, like missing out a water molecule, doesn’t just tweak a line on paper—it can change solubility, crystal shape, or how a chemical acts as a catalyst. In the case of 1,10-Phenanthroline Hydrate Hydrochloride, using the right form means the difference between a successful metal assay and frustrating, ambiguous results. In the pharmaceutical world and chemical engineering, these details thread through every decision. Researchers need that clarity, whether they’re studying coordination complexes or building sensitive analytical instruments.

The European Chemicals Agency and Sigma-Aldrich catalog list the monohydrate hydrochloride formula specifically because so many research protocols depend on knowing what’s truly in the bottle. Lab work comes down to reproducibility. There’s value in picking the standard, but also in knowing when your formulation has changed—an extra bit of water, for example, might cause a product to clump or degrade, cost money, and lead to waste.

How to Handle Common Confusion

A lot of new chemists mix up 1,10-Phenanthroline Hydrochloride and the monohydrate because so many similar-sounding substances crowd pharmacy stockrooms and scientific suppliers’ shelves. Suppliers sometimes shift between forms—one batch labeled with water, another anhydrous. I’ve learned to double-check Safety Data Sheets and consult the CAS registry number when any doubt lingers. If you keep your records detailed and store bottles away from humidity, you’ll save time.

I’ve seen a simple internal database—one built from hard-won experience—save labs hours of troubleshooting. Keeping batch numbers, formulas, and supplier codes visible clears up confusion, especially for undergrads or new hires still learning the ropes. In the end, knowing the correct formula—C12H9N2Cl·H2O—means accuracy, cost control, and better science.

What are the main applications of 1,10-Phenanthroline Hydrate Hydrochloride?

A Straightforward Tool in Chemistry

1,10-Phenanthroline hydrate hydrochloride turns up quietly but with impact in many corners of laboratory work. Chemists appreciate it for its chelating ability, meaning it can wrap itself around metal ions and hold them tight. This isn’t just for show—it's one of the go-to agents for detecting certain metals, especially iron. Toss it into a test with ferrous ions and it creates a strong orange-red complex that's hard to miss with the naked eye. Even with basic training, anyone can spot the color change. This practical feature lands the compound in countless routine analyses, from industrial batch monitoring to academic teaching labs. It saves time and avoids complicated equipment.

Helping Laboratories Keep Things Clean

I remember my first internship at a water treatment facility. The team ran standard tests for iron in samples from storage tanks, looking for rust leaks. Instead of fancy machines, they used phenanthroline solutions. Results came fast, costs stayed low, and nobody sweated over calibration drift or software faults. This low-stress approach fits busy public health labs, too, where quick results matter more than fancy gear.

Environmental chemists use the same reaction for detecting trace levels of metals. Water testing labs still rely on colorimetric kits featuring this compound, since it gets the job done on-site and in the field, even where power reliability dips.

Pushing Research on Ligands and Metal Complexes

University research teams love phenanthroline for what it can do in coordination chemistry. It helps build and stabilize metal complexes, unlocking new directions in drug development or catalysts. Students mix it with different metals and see firsthand how minor tweaks create totally fresh compounds. I’ve seen motivated young scientists using phenanthroline complexes as a jumping-off point for materials that respond to light or electricity. Their prototypes target solar energy conversion or recyclable batteries, and the science grows from stuff as accessible as phenanthroline salts.

Enabling Advances in Molecular Biology

Molecular biologists lean on the chelating power of this compound, too. There are experiments where copper ions need firm control, or where DNA-processing enzymes depend on particular metal ions. Here, phenanthroline acts as a gatekeeper, binding some metals and letting others do their work. Enzyme studies during my grad school days took advantage of this, teasing out mechanistic details by blocking or releasing the right ions at the right moments.

Driving Safer Chemical Processes

Fast food for thought: this compound also keeps chemical synthesis safer. There’s potential for runaway reactions with certain metals, and phenanthroline helps rein in those risks by putting the brakes on the free movement of ions. That's not just smart chemistry—it keeps more people safe in large-scale manufacturing.

Next Steps for Science and Industry

Supply chains get tight for fine chemicals, so researchers ought to push for more robust, green methods to make phenanthroline salts. Recycling waste metal solutions from process streams might open new doors. Training more science students in these reliable techniques helps, too—both for workforce demand and public confidence in affordable, proven analysis.

How should 1,10-Phenanthroline Hydrate Hydrochloride be stored?

Understanding the Compound

Handling chemicals like 1,10-Phenanthroline Hydrate Hydrochloride requires more than just following a list of protocols. I’ve spent years working with delicate chemical samples, learning the quirks that sometimes don’t show up in textbook guides. Anyone using this compound in a research or laboratory setting knows it comes as a crystalline solid, sensitive to moisture and light. One careless mistake can ruin a batch or, worse, create safety hazards for everyone in the room.

Why Storage Matters

This compound acts as a chelating agent and features in sensitive analyses, including iron detection. Its value in a laboratory depends on its stability. If humidity creeps in, or if heat and light get a chance to break down its structure, you get inconsistent results. In research, there’s nothing more frustrating than spending hours on a project only to trace the problem back to compromised chemicals. Keeping the quality high starts at the storage shelf, not the workbench.

Safe Storage Practices

From experience, one simple rule: a desiccator changes everything. 1,10-Phenanthroline Hydrate Hydrochloride soaks up moisture from the air. Even on a rainy afternoon, I’ve seen open containers cake up or form sticky clumps. A tightly sealed glass container—think amber bottles with reliable screw caps—keeps out humidity and light. Toss in a few silica gel packets alongside the bottle in the desiccator; they do wonders to keep things dry.

Some labs try to cut corners by using old plastic tubes, but chemicals like this don’t forgive shortcuts. Plastics can let in small amounts of moisture over time, and not all plastics block out light. Glass, especially amber glass, acts as a physical and light barrier. Good habits, such as double-checking a cap before putting a bottle away or labeling the opening date, prevent unwanted surprises weeks later.

Control Temperature and Light

Heat speeds up decomposition. This compound stays stable at room temperature but only if the space keeps cool—think 20-25°C with little fluctuation. I avoid keeping any sensitive reagent near radiators, sunny shelves, or any area with regular temperature changes. Direct sunlight can slowly break down even well-sealed chemicals. If storage space is limited, find a shaded spot in a chemical cabinet, away from acids and oxidizers. Some colleagues use temperature loggers to spot hidden problems, which pays off over time.

Keep It Separate, Keep It Safe

In our lab, everyone knows not to mix storage of organic chelators with reactive acids or strong oxidizers. 1,10-Phenanthroline Hydrate Hydrochloride won’t react dramatically at room temperature, yet long term, it’s just good sense to keep potential interactions at bay. Avoid shelves where accidental spills could mix it with incompatible chemicals. I organize by hazard class—not alphabetically—so accidental cross-contamination stays unlikely.

Training and Mindset

Too often, proper storage falls through the cracks when teams rush through routine tasks. New lab members should handle a guided walk-through on chemical storage. A label isn’t enough. Explaining the logic behind storage locations—the need to keep moisture and light away, the reason glass beats plastic—turns procedures into habits. Each safe day in the lab proves the point: storing chemicals the right way protects both results and people.

What is the purity and grade of the product?

Why Purity Means More Than a Number on a Label

Anyone walking into a hardware store or pharmacy often checks the label for purity. Maybe you want cleaning alcohol or baking soda. You scan the fine print and see something like 99% or USP grade stamped on the back. At first glance, that percentage looks straightforward. Higher must mean better, right? Yet there’s a story behind every number, and knowing it can mean the difference between success and a costly mistake.

A couple years ago, I tried to clean some stubborn electronics parts with acetone from a craft store. The residue clung to the circuit boards no matter how much I scrubbed. After some research, I learned that the product contained trace oils meant for nail polish removal. That “small” difference cost me an afternoon of frustration and a faulty device. It’s worth thinking about what goes into these grades and why lists of contaminants aren’t just a formality.

Grades Are More Than Buzzwords

Folks use “reagent grade,” “USP,” “technical,” and “food grade” in different industries. These words aren’t interchangeable jargon. “Food grade” salt, for example, has strict limits on heavy metals and additives. “Technical grade” salt lands on icy winter sidewalks, and nobody checks mercury levels quite as closely. Each label means the manufacturer stuck to a certain standard during production and testing. The fallout when these rules get ignored ranges from spoiled chemistry reactions in labs to actual health risks with contaminated medicines.

Some years back, the melamine milk scandal in China showed what happens when these standards get ignored or faked. Purity can literally be a life-or-death measure, not just a selling point. The details matter for more than just hospitals or research labs. Gardeners, mechanics, even home brewers run into trouble if they grab the cheapest available chemical without checking the grade.

Common Mistakes and Real-World Impact

I often hear from friends who cut corners trying to save a buck. More than once, someone’s ended up with clogged pipes from low-quality lye or failed fermentations from unfit sugars. Sometimes, the difference sits at a few tenths of a percent, but contaminants can sneak in. For pharmaceuticals, the stakes shoot even higher. Back in 2018, some blood pressure medications were recalled worldwide following detection of small amounts of carcinogens not screened out by certain suppliers. So no, both the percentage and the grade reference can’t be shrugged off.

Solutions: Making Sense of Grades and Purity

It’s easy to feel overwhelmed, but there’s some clear advice that fits. Always read labels and certificates of analysis when available. Trusted suppliers publish documentation, and open communication about testing helps prevent nasty surprises. In my experience, direct questions to distributors can lead to better choices. If a supplier dodges reasonable questions about content, take your money elsewhere.

Basic cross-referencing of regulatory or industry bodies (such as USP or ACS) provides reassurance. For bigger projects or anything health related, paying extra for a reliable grade pays off in the long run.

Wrap-Up: Knowledge Is the Best Safeguard

No label guarantees safety or fitness for every use. Purity and grade matter for reasons that touch quality, health, and sometimes even legality. Paying attention prevents headaches small and large. In my own workshop, I’ve stopped gambling with technical grades for projects that require reliability. It’s a simple shift that saves lots of trouble later, and businesses or hobbyists alike benefit from care up front.

Is 1,10-Phenanthroline Hydrate Hydrochloride hazardous, and what safety precautions should be taken?

The Risks Involved

In any lab, you develop a gut sense for which powders and liquids deserve a little extra respect. 1,10-Phenanthroline hydrate hydrochloride doesn’t have a scary odor or a trademark fluorescent color, but that doesn't mean it’s harmless. The crystalline form can irritate skin, eyes, and airways. Some folks ignore this because they don’t feel the discomfort until hours later. Once, after handling it without proper gloves during a rushed prep, my skin itched for the rest of the day. That seemed minor until breathing got tight after I wiped my face. Reading the safety data sheet made it clear: this stuff can be toxic, especially once inhaled.

Lab experience teaches you that if a compound can affect the nervous system or organs—like many nitrogenous bases—it finds a way when safety is ignored. Studies show ingestion or significant inhalation can lead to symptoms beyond irritation: trouble breathing, nausea, and headaches. That’s not a myth made up by over-cautious supervisors; it’s in published toxicology reports. Even the dust can pose problems, settling on surfaces or floating in the air if you leave the jar open or mix too briskly.

Protecting Yourself and Your Team

It’s tempting to skip full PPE on a hectic day, but gloves, goggles, and a decent lab coat are non-negotiable with 1,10-phenanthroline compounds. Cotton or nitrile gloves block direct contact. If there's a splash risk (think solution preparation), goggles with side shields prevent eye exposure. Lab coats keep your street clothes and skin safe from both powder and spills, and closed shoes protect against accidental drops.

Ventilated hoods remain the best place for any weighing or dissolving. I’ve seen too many colleagues develop mild asthma symptoms after years of exposure to chemicals once thought “low-risk.” Any procedure that generates dust or vapor—like transferring powder or dissolving large amounts—belongs in a fume hood. Cleaning up after a spill or loose powder should happen quickly, with damp wipes or HEPA-vacuum, never with dry sweeping or compressed air. Dry cleaning stirs up dust into the air, making things worse for everyone nearby.

Good labeling stops accidents before they start. Busy benches make it easy to mix up bottles or forget which powder you left open. Clear labels and a habit of sealing containers after every use go far in accidental avoidance. It’s surprising how often this basic discipline saves trouble.

Creating a Culture of Safety

Responsibility in research flows from top to bottom. New students copy what they see: if seniors treat these chemicals with respect, that habit sticks. Regular safety briefings and access to fact-based chemical safety data back up all the posted posters and reminders taped to fume hoods. In my early years, our PI brought in local emergency responders for a training session, including a dramatic re-enactment of a spill response. Watching a pro in full gear handle a simulated powder spill left an impression that lectures never did.

For labs working with potentially hazardous organics or metal complexes, routine air monitoring helps spot issues before people start coughing. Regular reviews of handling practices, sharing incident stories, and honest talk about near misses keep everyone alert.

No chemical is worth sacrificing safety or health. The small habits—checking a glove for pinholes, keeping containers sealed, cleaning up spills fast—make a huge difference. 1,10-Phenanthroline hydrate hydrochloride will do its job without causing trouble, as long as everyone in the lab remembers the risks and treats them with the respect they demand.

1,10-Phenanthroline Hydrate Hydrochloride
Names
Preferred IUPAC name 4,5-Diazaphenanthren-4-ium chloride monohydrate
Other names o-Phenanthroline hydrochloride monohydrate
1,10-Phenanthroline hydrochloride hydrate
Phenanthroline hydrochloride hydrate
Phen hydrochloride monohydrate
Pronunciation /ˌwʌnˌtɛn fɪˈnænθrəˌliːn haɪˈdreɪt haɪˌdrɒxɪˈklaɪd/
Identifiers
CAS Number 5144-89-8
Beilstein Reference 1226944
ChEBI CHEBI:38740
ChEMBL CHEMBL1478
ChemSpider 23453940
DrugBank DB11350
ECHA InfoCard 05b1b95a-6008-4c32-b379-1f964e1c8f62
EC Number 207-737-2
Gmelin Reference 58260
KEGG C01442
MeSH D010630
PubChem CID 23665777
RTECS number SM8650000
UNII UKP8N5YWXJ
UN number UN2811
Properties
Chemical formula C12H9ClN2·H2O
Molar mass 377.86 g/mol
Appearance White to off-white powder
Odor Odorless
Density 1.3 g/cm³
Solubility in water Soluble
log P -0.1
Acidity (pKa) 5.04
Basicity (pKb) -4.94
Magnetic susceptibility (χ) -61.5·10⁻⁶ cm³/mol
Refractive index (nD) 1.657
Dipole moment 1.634 D
Thermochemistry
Std enthalpy of formation (ΔfH⦵298) -431.2 kJ/mol
Hazards
Main hazards Harmful if swallowed, causes serious eye irritation, causes skin irritation.
GHS labelling GHS02, GHS07
Pictograms GHS05,GHS07
Signal word Warning
Hazard statements H302, H315, H319, H335
Precautionary statements P264, P270, P273, P301+P312, P330, P501
NFPA 704 (fire diamond) 1,2,0
Lethal dose or concentration LD50 Oral Rat 1320 mg/kg
LD50 (median dose) LD50 (median dose): Oral rat LD50: 132 mg/kg
PEL (Permissible) Not established
REL (Recommended) 100 mg
IDLH (Immediate danger) Not established
Related compounds
Related compounds Phenanthroline
1,10-Phenanthroline
1,10-Phenanthroline monohydrate
1,7-Phenanthroline
2,9-Dimethyl-1,10-phenanthroline
Bathophenanthroline
Neocuproine
Hydrochloride
Bipyridine